VL260
Quick Reference Guide
Action Required
The Control Panel will be disabled until power returns.
Spa settings will be preserved until the next power up..
After the Circulation Pump has been running for 2 minutes, the
temperature will be displayed.
DO NOT ENTER THE WATER. Remove the Spa Cover and allow
water to cool. Once the Heater has cooled, reset by pushing any
button. If Spa does not reset, shut off the power to the Spa and call
your Dealer or Service Organization.
If the problem persists, contact your Dealer or Service Organization.
Check water level in Spa. Refill if necessary. If the water level is
correct, make sure the pumps have been primed. Turn Spa off, take
out and clean the filters with filter cleaner. Turn Spa back on again to
restore heating. If problem persists, contact your Dealer or Service
Organisation.
Check water level in Spa. Refill if necessary. If the water level is
correct, make sure the pumps have been primed. Press any button
to reset.
Priming Mode will last for up to 4 minutes and then the Spa will begin
to heat and maintain the water temperature in the Standard Mode.
Meaning
No message on display.
Power has been cut off to the Spa.
Temperature unknown
‘Overheat’ - The Spa has shut down. One of the sensors has
detected that the Spa water is (approximately 43.3°C).
Sensors are out of balance. If altering with temperature, it may just be
a temporary condition, if flashing by itself, Spa is shut down.
A substantial difference between the temperature sensors was
detected. This could indicate a flow problem.
Inadequate water detected in Heater.
When the Spa is first activated it will go into Priming Mode.
DIAGNOSTIC MESSAGES
Message
--
OH
SN
LF
DR
PR