TP900/800 Series Programming Highlights
Filtration
The system is factory-programmed with one filter cycle (Be sure to set the time-of-day properly). The filter time and duration are programmable.
Refer to the TP900/800 User Guide (40985) for detailed instructions.
A second filter cycle can be enabled as needed.
Dual Temperature Ranges
This system incorporates two temperature range settings with independent set temperatures. The
High
Range
can be set between
80°F and 104°F.
The
Low Range
can be set between
50°F and 99°F.
Low
Range may be economical during non-use periods. See “Settings” on the Main Screen.
Restricted temperature ranges may determined by the manufacturer.
Ready and Rest Modes
If the filtration pump is a 2-Speed Pump 1,
Ready Mode
will circulate water every 1/2 hour, using
Pump 1 Low, in order to maintain a constant water temperature, heat as needed, and refresh the
temperature display. This is known as “polling.”
Rest Mode
will only allow heating during programmed filter cycles. Since polling does not occur, the temperature display may not show a current
temperature until the filtration pump has been running for a minute or two.
Ready in Rest Mode
may appear when Jets 1 is activated.
42274_A 12/23/14
www.balboawater.com
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
Set:
104°F
8:32 PM
Ozone
Filter 1
Spa
Shortcuts
Settings
High Range
102°F
Ready in Rest Mode
Heating
Note: After 3-5 minutes the display will automatically go into sleep mode, which turns the
display off. This is normal operation. Press any button on the screen to wake the panel up.