background image

40940_N

02-08-19

4

Manufactured under one or more of these patents.  U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 

6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and 

domestic applied for and pending.   All material copyright of Balboa Water Group.

Pumps

Press the “Jets 1” button once to turn pump 1 on or off, and to shift between low- and high-speeds if equipped.  
If left running, the pump will turn off after a time-out period. The pump 1 low-speed will time out after 30 minutes. The 
high-speed will time out after 15 minutes.
On non-circ systems, the low-speed of pump 1 runs when the blower or any other pump is on. If the spa is in Ready Mode 
(See page 6), Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa temperature (polling) 
and then to heat to the set temperature if needed. When the low-speed turns on automatically, it cannot be deactivated 
from the panel, however the high speed may be started.

Circulation Pump Modes

If the system is equipped with a circ pump, it will be configured to work in one of three different ways:
1, The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the 
water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).
2, The circ pump stays on continuously, regardless of water temperature.
3, A programmable circ pump will come on when the system is checking temperature (polling), during filter cycles, during 
freeze conditions, or when another pump is on.
The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the field.

Filtration and Ozone

On non-circ systems, Pump 1 low and the ozone generator will run during filtration. On circ systems, the ozone will run with 
the circ pump.
The system is factory-programmed with one filter cycle that will run in the evening (assuming the time-of-day is properly 
set) when energy rates are often lower. The filter time and duration are programmable. (See page 10) 
A second filter cycle can be enabled as needed.
At the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is one) will run briefly to purge its plumb-
ing to maintain good water quality. 

Freeze Protection

If the temperature sensors within the heater detect a low enough temperature, then the pump(s) and the blower automati-
cally activate to provide freeze protection. The pump(s) and blower will run either continuously or periodically depending 
on conditions.
In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not 
be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds 
determined by the switch. See your dealer for details.

Clean-up Cycle (optional)

When a pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is 
turned off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the system. On 
some systems, you can change this setting. (See the Preferences section on page 12)

Spa Behavior

Содержание TP600

Страница 1: ...tent 2373248 other patents both foreign and domestic applied for and pending All material copyright of Balboa Water Group TP600 and TP400 Control Panels User Interface and Programming Reference Standard Menus System Model BP Series Systems are BP5XX BP6XX BP1XXX BP2XXX Software Version 7 0 and later Panel Model TP600 Series TP400 Series Software Version 2 3 or later 2 4 or later JETS AUX LIGHT HEA...

Страница 2: ...hoose button depending on control panel configuration Indicates Alternating or Progressive Message every 1 2 second Waiting time that keeps the last change to a menu item Waiting time depends on menu item that reverts to original setting and ignores any change to that menu item Navigation Navigating the entire menu structure is done with 2 or 3 buttons on the control panel Some panels have separat...

Страница 3: ... As soon as the above display appears on the panel push the Jet button once to start Pump 1 in low speed and then again to switch to high speed Also push the Pump 2 or Aux button if you have a 2nd pump to turn it on The pumps will now be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pumps ...

Страница 4: ... temperature polling during filter cycles during freeze conditions or when another pump is on The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the field Filtration and Ozone On non circ systems Pump 1 low and the ozone generator will run during filtration On circ systems the ozone will run with the circ pump The system is factory programme...

Страница 5: ...n be used for various reasons with a common use being a ready to use setting vs a vacation setting The Ranges are chosen using the menu structure below Each range maintains its own set temperature as programmed by the user This way when a range is chosen the spa will heat to the set temperature associated with that range For example High Range might be set between 80 F and 104 F Low Range might be...

Страница 6: ... on and off Pump 1 Low will run until set temperature is reached or 1 hour has passed After 1 hour the System will revert to Rest Mode This mode can also be reset by entering the Mode Menu and changing the Mode Mode Ready and Rest READY SET SET REST Sub Menu Detail MODE Ready and Rest READY Mode will allow the spa to Poll and determine a need for heat The panel will maintain a current temperature ...

Страница 7: ...system will still operate and all other user settings will be stored If filter cycles are required to run at a particular time of day resetting the clock will return the filter times to the actual programmed periods When the system starts up it defaults to 12 00 Noon so another way to get filter times back to normal is to start up the spa at noon on any given day SET TIME will still flash in the T...

Страница 8: ...ADY RANGE FLTR1 SET To Set To next item in Main Menu A Few Seconds A Few Seconds A few seconds RANGE Waiting a few seconds reverts to origianl settings Sub Menu Detail Unlocking the Set Temperature or All Buttons While pressing and holding the Temperature Button or UP button if available Slowly press and release the Light Button two times READY RANGE FLTR1 Main Screen A Few Seconds Unlocking Indic...

Страница 9: ... seconds Main Screen READY RANGE FLTR1 a few seconds or To next item in Main Menu SET Hold Mode M037 Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filter Hold Mode will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature i...

Страница 10: ...Waiting a few seconds reverts to original setting Wait to Revert Waiting a few seconds reverts to original setting Waiting a few seconds will lose any new Filter 1 Start Time and Run Hours and revert to the previous Filter 1 settings To Set Waiting a few seconds will lose any new Filter 2 On OFF Start Time and Run Hours and revert to any previous Filter 2 settings Wait to Revert Main Filtration Fi...

Страница 11: ... an hour SET A SET A SET A Sets 15 minute increments SET A SET SET SET Shows flashes start time to show RUN HRS to show TIMR ENDS xx xx Sets 15 minute increments A Waiting a few seconds reverts to origianl settings Wait to revert Waiting a few seconds reverts to origianl settings OR OR OR To next item in Main Menu Main Screen READY RANGE FLTR1 Main Screen READY RANGE FLTR1 Waiting a few seconds wi...

Страница 12: ... clock between 12 hr and 24 hr display RE MIN DERS Reminders Turn the reminder messages like Clean Filter On or Off CLN UP Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is available set the length of time Pump 1 will run after each use 0 4 hours are available DOL PHIN AD DRES Dolphin II and Dolphin III Applies to RF Dolphin only This message may not appear depen...

Страница 13: ...s Light for CLEAN UP 05 15 09 While the Temperature is still flashing press Light repeatedly until PREF appears in the LCD SET RANGE Main Screen READY RANGE FLTR1 To next item in Main Menu UTIL To next item in Main Menu UTIL To view current setting and to toggle number of hours 0 4 SET SET SET To veiw current setting and to toggle address numbers for Dolphin II or Dolphin III 0 7 SET SET SET to sh...

Страница 14: ...the bottom of the screen SSID Software ID Displays the software ID number for the System MODL System Model Displays the Model Number of the System SETP Current Setup Displays the currently selected Configuration Setup Number Heater Voltage Feature not used on CE rated systems Displays the operating voltage configured for the heater Heater Wattage as Configured in Software CE Systems Only Displays ...

Страница 15: ...bled so it may not appear This screen allows the GFCI to be tested manually from the panel and can be used to reset the automatic test feature If the GFCI Test Feature is reset the device will trip within 7 days See Page 17 A B A B Sensor Temperatures When this is set to On the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater FALT LOG Fault Log The...

Страница 16: ...tilities appears in the LCD SET RANGE Main Screen READY RANGE FLTR1 SET SET SET When set to ON Panel will display alternate readings from Senor A and Sensor B on Main Screen Back to normal operation DIP Switch 1 Test Mode Off 0 or On 1 N A or Special Amperage Rule 1 or 2 120 or 240 VAC input power sensed by a UL system at startup 3 6 or 1 3 Heater Wattage as programmed Displayed by a CE system at ...

Страница 17: ...thin a few seconds and the spa should shut down If it does not shut down the power and manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly Verify the function of the GFCI with its own test button Restore power to the spa and repeat the GFCI Trip Test Once the GFCI is tripped by the test reset the GFCI and the spa will operate normally from that point Y...

Страница 18: ...e Sensor ATemp Sensor B Temp 24 Fault messages is the maximum Fewer messages may be displayed To FIRST item in Main Menu TEMP Range While the Temperature is still flashing press Light repeatedly until UTIL Utilities appears in the LCD Press Light repeatedly until FALT LOG appears in the LCD SET RANGE Main Screen READY RANGE FLTR1 READY RANGE SET READY RANGE READY RANGE READY RANGE READY RANGE READ...

Страница 19: ...e is exited Water is too Hot OHS M029 One of the water temp sensors has detected spa water temp 110 F 43 3 C and spa functions are disabled System will auto reset when the spa water temp is below 108 F 42 2 C Check for extended pump operation or high ambient temp This message can be reset from the topside panel with any button press M0XX numbers are Message Codes See Page 18 Too Cold Freeze Protec...

Страница 20: ...ry dr M028 Possible dry heater or not enough water in the heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry M027 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must press any button to reset and restart heater start up See Flow Related Checks ...

Страница 21: ...out of sync by 2 F or 3 F Call for Service Sensor Balance is Poor M026 The temperature sensors ARE out of sync The Sensor Balance is Poor fault has been established for at least 1 hour Call for Service Sensor Failure Sensor A M031 Sensor B M032 A temperature sensor or sensor circuit has failed Call for Service READY RANGE FLTR1 No Communications The control panel is not receiving communication fro...

Страница 22: ... Failure System Could Not Test Trip the GFCI M036 NORTH AMERICA ONLY May indicate an unsafe installation Contact your dealer or service organization A Pump Appears to have been Stuck ON when spa was last powered M035 POWER DOWN THE SPA DO NOT ENTER THE WATER Contact your dealer or service organization A Pump Appears to be Stuck ON M034 Water may be overheated POWER DOWN THE SPA DO NOT ENTER THE WA...

Страница 23: ...D is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function Alternates with temperature or normal display Alternates with temperature or normal display Alternates w...

Страница 24: ...ood skirting and furniture should be cleaned and conditioned per the manufacturers instructions for maximum life Appears on a regular schedule e g every 365 days Filters should be replaced occasionally to maintain proper spa function and sanitary conditions As needed Install new mineral cartridge Appears on a regular schedule e g every 365 days Check your ozone and or UV generator per your spa man...

Страница 25: ...ad the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitably rated s...

Отзывы: