Balboa ML900 Скачать руководство пользователя страница 4

Temp Set 

(80°F - 104°F / 26.0°C - 40.0°C)

The last measured temperature is constantly displayed 
on the LCD.

Note that the last measured spa temperature 
displayed is current only when the pump has been 
running for at least 2 minutes.

Warm/Cool  

  

Press the “Warm” or “Cool” button once to display the 
set temperature. Each time either button is pressed again, 
the set temperature will increase or decrease depending 
on which button is pressed. After three seconds, 
the LCD will automatically display the last measured 
spa temperature.

Mode/Prog  

This button is used to switch between Standard, 
Economy, and Sleep modes. Press “Mode/Prog” to enter 
mode programming, press “Cool” to cycle through to 
desired mode (LCD flashes until confirmed), then press 
“Mode/Prog” to confirm selection.

Standard mode 

maintains the desired temperature. 

Note that the last measured spa temperature displayed 
is current only when the pump has been running for at 
least 2 minutes. The “

” icon will display until 

the mode is changed.

Economy mode

 heats the spa to set temperature only 

during filter cycles. The “

” icon will display 

until mode is changed.

Pressing “Jets 1” while in Economy mode puts the 
spa in 

Standard-In-Economy mode, 

which operates 

the same as Standard Mode, then reverts to Economy 
Mode automatically after 1 hour. Both the “

and “

” icons display in this mode. During this 

time, a press of the “Mode/Prog” button will revert to 
Economy Mode immediately.

Sleep mode

 heats the spa to within 20°F (11°C) of the 

set temperature only during filter cycles. The “

icon will display until mode is changed.

Standby Mode

Pressing “Warm” or “Cool” then “Jets 2” will turn off all 
spa functions temporarily. This is helpful when changing 
a filter. Pressing any button resets the spa. On some 
systems the “Jets 1” button will control the pump in 
Standby Mode (“Drain Mode”). In this case, press any 
other button to exit. System will revert to previous mode  
after 1 hour.

Jets 1  

Press the “Jets 1” button once to turn pump 1 on or off, 
and to shift between low and high speeds if equipped. 
If left running, the pump will turn off after a timeout 
period. The pump 1 low speed timeout on some systems 
may be as long as 4 hours.

On non-circ systems, the low speed of pump 1 runs 
when the blower or any other pump is on. It may also 
activate for at least 2 minutes every 30 minutes to detect 
the spa temperature (polling) and then to heat to the 
set temperature if needed, depending upon mode. 
When the low speed turns on automatically, it cannot 
be deactivated from the panel; however, the high speed 
may be started.

Time  

When time hasn’t been programmed, the “

” icon 

flashes. To set the time, press “Time” then “Mode/Prog.” 
Use the “Warm” and “Cool” buttons to adjust time. 
See previous page for more detailed instructions. 

(Time settings on EL1000 and EL2000 systems are not 
preserved in the event of power loss; time will have to be 
reprogrammed upon each power up.)

If your spa has an optional pH/ORP sensor (not 
available on EL1000 and some EL2000 systems), pressing 
“Time” twice will display the current pH level; pressing 
it three times will display the current ORP.

Page 2

Setting the Time

Once the spa has been properly connected the first time (every 
power up on the EL1000 and EL2000 systems), notice the “

” icon 

appearing on the screen.

Press

Then

Select 

the hour by pressing

Press

to exit the time setting procedure and enter 
the optional filter cycle programming. (Exits 
programming on EL1000 and some EL2000 systems.)

Time

Time

Press

to exit programming.

Press

to enter.

Select 

minutes by pressing

Mode/Prog

Mode/Prog

Time

Time

Mode/Prog

Mode/Prog

Mode/Prog

Mode/Prog

Or

(Each press changes the 
time by 1 minute)

Warm

Warm

Cool

Cool

Or

(Each press changes the 
time by 1 minute)

Warm

Warm

Cool

Cool

Содержание ML900

Страница 1: ...ght F2 TL F1 PL ML900 User Guide EL GL Series Mach 2 1 Note regarding EL and GL systems Mach 2 1 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL systems for the sake of simplicity but the information given applies to both EL and GL products YXcYfX ejkild ekj Zfd ...

Страница 2: ......

Страница 3: ...Jets 1 2 Jets 2 3 Jets 3 3 Blower 3 Invert 3 Preset Filter Cycles 3 Optional Filter Cycle Programming 3 Light 4 Option 4 Fiber 4 Freeze Protection 4 Locking the Panel 4 Locking the Set Temperature 4 Clean up Cycle 4 Circ Pump 4 Ozone 5 Displaying Information About Your Spa 5 User Preferences 5 Editing User Preferences 5 Diagnostic Messages 6 7 Periodic Reminder Messages 8 Optional Auxiliary Panels...

Страница 4: ...utton will control the pump in Standby Mode Drain Mode In this case press any other button to exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a timeout period The pump 1 low speed timeout on some systems may be as long as 4 hours On no...

Страница 5: ... after the spa is powered up The second filter cycle night begins 12 hours later Filter duration is programmable for 1 12 hours The default filter duration can vary from system to system To program press Warm or Cool then Jets 1 Press Warm or Cool to select the filter duration Press Jets 1 to select the number of filter cycles The display will show both day and night cycles day cycle only or night...

Страница 6: ...e wheel stop Freeze Protection If the temperature sensors within the heater detect a low enough temperature then the pumps and the blower automatically activate to provide freeze protection The equipment stays on for at least 4 minutes and until the sensors detect that the spa temperature is warm enough In colder climates an optional additional freeze sensor may be added to protect against freeze ...

Страница 7: ...ettings Suppress Reminders When set to reminders are never displayed on the panel When set to reminders are displayed on the panel periodically Temperature in Celsius When set to temperatures are displayed on the panel in degrees Celsius When set to temperatures are displayed in Fahrenheit 24 hour Time Display When set to time is displayed in 24 hour military format 00 00 is midnight 23 00 is one ...

Страница 8: ... EL2000 systems reset the time of day on each power up Spa settings are preserved on all systems DO NOT ENTER THE WATER Remove the spa cover and allow water to cool Once the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and allow water to cool At 107 F approx...

Страница 9: ...ll be displayed In Economy or Sleep mode the pump may be off for hours outside a filter If you wish to see the current spa temperature either switch to Standard mode or turn Jets 1 on for at least 2 minutes Press any button to leave Standby Mode and return to normal operation Add pH increaser according to manufacturer s instructions Add pH reducer according to manufacturer s instructions Add saniti...

Страница 10: ...structions Every 30 days Test reset GFCI per manufacturer s instructions Every 90 days Drain and refill spa per manufacturer s instructions Every 180 days Clean and condition cover per manufacturer s instructions Every 180 days Clean and condition wood per manufacturer s instructions Every 365 days Install new filter As needed Install new Mineral cartridge User can suppress all reminders in User P...

Страница 11: ...y as Jets 5 Mister optional Press the Mister button to turn the Mister on and off If left on the mister will automatically turn off after 15 minutes TV Lift optional Press the TV Lift button to raise and lower the TV Lift device There is no timeout for this feature Optional Auxiliary Panels Note Below is a partial list of optional auxiliary panels and their basic functions Please contact for local...

Страница 12: ... ground fault circuit interrupter before each use of the spa Read the instruction manual Adequate drainage must be provided if the equipment is to be installed in a pit For use only within an enclosure rated CSA Enclosure 3 Connect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when ...

Отзывы: