39

GS Persistent Memory with VL Panels

Any time you change a DIP Switch, other than A1, you must reset Persistent 
Memory for your new DIP Switch Settings changes to take effect. If you do 
not reset Persistent Memory, your system may function improperly.

To reset Persistent Memory:

>

Power down by disconnecting power source from spa.

>

Put a jumper on across J43, covering both pins. (See illustration below)

>

Power up by connecting power source to spa.

>

Wait until “

” is displayed on your panel.

>

Power down again.

>

Remove jumper from J43 (May also move to cover 1 pin only)

>

Power up again.

About Persistent Memory and Time of Day Retention:

This system uses memory that doesn’t require a battery to store a variety of 
settings.  What we refer to as Persistent Memory stores the filter settings, 
the set temperature, and the heat mode.

Persistent Memory is not used for Time of Day.  Only models with a 
Serial Deluxe panel installed (GS5xxDZ) can display the time. 
However, during power loss to the spa, the system will lose the 
correct time, and reset to 12:00 PM when power is restored.

Power Up Display Sequence

Upon power up, you should see the following on the display:

>

Three numbers in a row, which are the SSID (the System Software 
ID).  The third display of these numbers is the Software Version, 
which should match the version of your system.  For example, if these 
three numbers are 

  

  

, that is a VS511SZ at version 38.

>

Displayed next is: “

” (indicating the system is configured for 

a heater between 3 and 6 kW) or “ ” (indicating the system is 
configured for a heater effectively* between 1 and 3 kW).

” should appear for all VS models running at 240VAC.

“ ” should appear for all VS models running at 120VAC, as well 
as all GS models.  (*A heater which is rated at 4 kW at 240VAC will 
function as a 1 kW heater at 120VAC.)

>

” will appear to signal the start of Priming Mode.

At this point, the power up sequence is complete.  Refer to the Reference 
Card for the GS System model of your spa for information about how 
the spa operates from this point on, including how to adjust the Time of 
Day if using a Serial Deluxe style panel.

G

C

G

C

G

C

G

C

C

G

RED AC

WHT AC

T

BLK AC

J32

J61 J62

T1

SWITCHBANK A

J11

J66 J65

J15 J16 J25 J63 J64

J33 J34

J36

J37

J35

BALBOA INSTRUMENTS, INC.

VS500Z

P/N  22972 REV D

MADE IN U.S.A

COPYRIGHT 2005

S1

J6

J7

J8

J44

J60

J22

U4

HTR2

HTR1

J101

J100

TB1

FUSE .3A 250V

FUSE 20A 250V

FUSE 3A 250

V

E.

GN

D

CLASS G   FUSE 30A

F5

F4

K6

K1

K8

K9

K5

J23

J46J46

F1

J29

J47

J50

F7

J17

/26

J20

J1A

J10

J13

J2A

EXT.

RLY

TST

AUX. F

SEN. A SEN. B

VAC

W1

W7

J1

J2

W2

W3

G

C

W4

K4

K2

K3

Balboa

F2

J12

1

2 3

J43

2-SPD

EXT RLY

J1

8

TORQUE

RANGE

FOR TB1:

27-30 IN. LBS.

HO

T

BLACK

NEUTRAL

WHITE

HO

T

RED

SWITCHBANK A

S1

J6

E.GND

TST

J43

J43 on 

G

S Series Main Board Shown.

Содержание ML550

Страница 1: ... exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a time out period The pump 1 low speed time out on some systems may be as long as 4 hours On non circ systems the low speed of pump 1 runs when the blower or any other pump is on It may ...

Страница 2: ...me circ systems pump 1 may also run for the duration of the filter Note This panel cannot be used to program filter cycles for systems that are programmed by time rather than by duration For these systems a larger panel is needed and the following description does not apply The first filter cycle day begins 6 minutes after the spa is powered up The second filter cycle night begins 12 hours later Filter...

Страница 3: ...e within 3 seconds of the previous press Then press Cool until you see on the display Press Jets 1 to see the SSID a series of 3 numbers such as 100 133 10 which indicates the precise revision of the software in your spa followed by the Mach software version number such as 2 1 followed by and then your spa s network ID number consisting of both letters and digits displayed in 5 steps If you need t...

Страница 4: ...witch editing of the value on flashing or off not flashing Once you re editing the value it s flashing use the Cool or Warm buttons to change the value to the one you want After you change the value you must press Jets 1 again to stop the flashing before the change will register and before you can view or edit another setting If you don t interact with the menu for more than 30 seconds it may time out...

Страница 5: ...e depending on your manufacturer s settings Note that the last measured spa temperature displayed is current only when the pump has been running for at least 1 minute Temp ML400 Press the Temp button once to display the set temperature To change the set temperature press the pad a second time before the LCD stops flashing Each press of the Temp button will continue to either raise or lower the set ...

Страница 6: ...a time out period Blower optional on some systems ML400 If your system has a blower and only one pump but your panel does not have a Blower button use the Aux button to control the blower 1 speed operation on off 2 speed operation med hi off or 3 speed operation lo med hi off If left on the blower will automatically turn off after a time out period Circ Pump optional ML400 If your system is equipp...

Страница 7: ...nel Preset Filter Cycles ML400 On all systems the pump and the ozone generator will run during filtration At the start of each filter cycle the blower will run briefly on its highest speed to purge the air channels The lowest speed of any other pumps and the mister will also run briefly On some circ systems pump 1 may also run for the duration of the filter Note This panel cannot be used to program fil...

Страница 8: ...Dolphin II which is set for no address which is the Dolphin II factory default When set to through the number is the address see your Dolphin II manual for details Editing User Preferences ML400 View the setting The left two characters before the decimal point tell you what setting you re viewing or editing the right most character after the decimal point tells you the value of that setting for ex...

Страница 9: ...d a configuration problem For example s would mean that the combination of how you ve set A5 and how you ve set B2 is not supported on this system s would mean that there is a problem with jumper J99 s would mean that the combination of how you ve set pump 3 for 1 speed and blower for 1 speed is not supported on this system s would mean that the combination of how you ve set DIP switches which hav...

Страница 10: ...EMS Warm Blower Light Mode Mode Warm Heat Cool Jets 1 Light Blower Jets 2 Blower Warm Heat Jets 1 Jets 2 Blower Light Mode Warm Cool Heat Jets Blower Light Warm Cool Mode Jets Blower Light Heat Jets Blower Light Warm Cool Mode Jets Blower Light Heat Blower Time Warm Mode Prog Cool Jets 1 Light Jets 2 Time Mode Prog Time Warm Blower Light Cool Mode Prog Jets 1 Jets 2 ...

Страница 11: ...ets Light Warm Cool Heat Jets Light Blower Temp Heat Set Blower Jets Light Blower Set Heat Note VL404 and VL403 have red LED s on black background Heat Blower Blower Jets Light Temp Heat Blower Set Jets Blower Light Heat Blower Blower Jets Light Temp Jets Jets Light Blower Temp Jets Jets Jets Light Blower Blower Temp ...

Страница 12: ...ets button s repeatedly and be sure all pumps are free of air Priming Mode lasts less than 5 minutes Press Temp to exit After Priming Mode the spa will run in Standard Mode see Mode section Some panels may not have a Temp button On these panels the Set Warm or Cool buttons are used The pump responsible for heating and filtration pump 1 low speed on non circ system or the circ pump on circ systems w...

Страница 13: ...will be locked in Standard Mode Mode is changed by pressing UÊ Temp then Light STANDARD Mode maintains set temperature UÊ will be displayed momentarily when you switch into Standard Mode ECONOMY Mode heats the spa to the set temperature UÊ only during filter cycles will display when water temp is not current and will alternate with water temp when the pump is running SLEEP Mode heats the spa to wit...

Страница 14: ...nd Cool within 2 seconds Note On some systems Jets 1 instead of Blower is UÊ used in Lock Unlock sequences OZONE For non circ systems if installed runs during filtration For circulation systems if installed runs 24 hours FILTER CYCLES Preset Filter Cycles 500Z The first preset filter cycle begins 6 minutes after the UÊ spa is energized The second preset filter cycle begins 12 hours later Filter durati...

Страница 15: ...oftware Version which should match the version of your system For example if these three numbers are that is a VS511SZ at version 38 Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is configured for a heater effectively between 1 and 3 kW should appear for all VS models running at 240VAC should appear for all VS models running at 120VA...

Страница 16: ...sure Remove the board from the plastic stand offs by gently UÊ squeezing the locking flange on each stand off with a pair of pliers The board should now be free and can be removed from the system box HOW TO REPLACE A SYSTEM CIRCUIT BOARD Check all jumpers and dip switch positions on the new UÊ board Make sure they are in the same position as the old board Make sure the new board snaps in place on t...

Страница 17: ...not a connection problem If the problem continues after following the above UÊ steps then replace the circuit board Check sensor wires for cracks or damage that may 1 indicate the presence of a rodent Inspect the connections of both sensors on the circuit 2 board The plugs must be clean If the sensors are not totally failing but are showing 3 excessive 1 0 C 2 0 F or more difference between the tw...

Страница 18: ...es until water flows out If the connectors are on too tight it may be necessary to loosen the Phillips screws that hold the connectors together Once the water has been drained continue Remove the system door cover 4 Remove the nuts securing the copper straps to the 5 heater assembly s terminal connectors Be sure to use a supporting end wrench on the lower nut Otherwise excessive torque may be occur...

Страница 19: ...VDUJPOT Reminder Suppress in User Preferences 2 4ZTUFN DPOmHVSFE JODPSSFDUMZ FOV QBOFM EJTQMBZT FSSPST POUBDU BMCPB 1MFBTF TFF i JBHOPTJOH 5PQTJEF POUSPM 1BOFMTw 1BHF JSNXBSF JOTUBMM QSPCMFN POUBDU BMCPB JG NFTTBHF BQQFBST PO NPSF UIBO POF QPXFS VQ 1MFBTF TFF i JBHOPTJOH 5PQTJEF POUSPM 1BOFMTw 1BHF 1BOFMT OBEFRVBUF XBUFS EFUFDUFE JO IFBUFS IFDL XBUFS MFWFM JO TQB 3FmMM JG OFDFTTBSZ G UIF XBUFS MFW...

Страница 20: ...FS MFWFM JO TQB 3FmMM JG OFDFTTBSZ G UIF XBUFS MFWFM JT PLBZ NBLF TVSF UIF QVNQT IBWF CFFO QSJNFE 1SFTT BOZ CVUUPO UP SFTFU TVCTUBOUJBM EJGGFSFODF CFUXFFO UIF UFNQFSBUVSF TFOTPST XBT EFUFDUFE 5IJT DPVME JOEJDBUF B nPX QSPCMFN IFDL XBUFS MFWFM JO TQB 3FmMM JG OFDFTTBSZ G UIF XBUFS MFWFM JT PLBZ NBLF TVSF UIF QVNQT IBWF CFFO QSJNFE 1SFTT BOZ CVUUPO UP SFTFU i0WFSIFBUw 5IF TQB IBT TIVU EPXO 0OF PG UI...

Страница 21: ...OZ CVUUPO 5FTU TFOTPST BSEXBSF GBJMVSF POUBDU BMCPB JG NFTTBHF BQQFBST PO NPSF UIBO POF QPXFS VQ Q JT IJHI EE Q SFEVDFS BDDPSEJOH UP NBOVGBDUVSFS T JOTUSVDUJPOT Q JT MPX EE Q JODSFBTFS BDDPSEJOH UP NBOVGBDUVSFS T JOTUSVDUJPOT 8IFO ZPVS TQB JT mSTU BDUVBUFE JU XJMM HP JOUP 1SJNJOH NPEF 4FF UIF OTUBMMBUJPO OTUSVDUJPO BOVBM GPS DPNQMFUF JOTUSVDUJPOT PO 1PXFS VQ BOE 1VNQ 1SJNJOH 5IF 1SJNJOH NPEF XJMM ...

Страница 22: ... i w KBDL JT OPU XPSLJOH G UIF QSPCMFN QFSTJTUT DPOUBDU BMCPB BZ BQQFBS UFNQPSBSJMZ JO BO PWFSIFBU DPOEJUJPO 4FF i5FTUJOH UIF 4FOTPS 4FUw 1BHF 4BOJUJ FS JT IJHI 3FNPWF TQB DPWFS BOE BMMPX TBOJUJ FS UP EJTTJQBUF 4BOJUJ FS JT MPX EE TBOJUJ FS BDDPSEJOH UP NBOVGBDUVSFS T JOTUSVDUJPOT 4UBOECZ PEF IBT CFFO BDUJWBUFE CZ QSFTTJOH B CVUUPO DPNCJOBUJPO PO UIF VTFS QBOFM 1SFTT BOZ CVUUPO FYDFQU i FUT w UP M...

Страница 23: ...5IF TQB IBT TIVU EPXO 0OF PG UIF TFOTPST IBT EFUFDUFE UIBU UIF TQB XBUFS JT BQQSPY 0 05 5 3 5 8 5 3 3FNPWF UIF TQB DPWFS BOE BMMPX XBUFS UP DPPM U BQQSPYJNBUFMZ UIF TQB TIPVME BVUPNBUJDBMMZ SFTFU G TQB EPFT OPU SFTFU TIVU PGG UIF QPXFS UP UIF TQB 4UBOECZ PEF IBT CFFO BDUJWBUFE CZ QSFTTJOH B CVUUPO DPNCJOBUJPO PO UIF VTFS QBOFM 1SFTT BOZ CVUUPO UP MFBWF 4UBOECZ PEF BOE SFUVSO UP OPSNBM PQFSBUJPO 5I...

Страница 24: ...48 40921 Rev A October 31 2008 Tustin Ca 92780 714 384 0384 2008 Balboa Water Group All rights reserved ...

Отзывы: