P/N 40299   05/28/2004

Warning! Shock Hazard! No User Serviceable Parts.

Do not attempt service of this control system.  Contact your dealer or service organization for assistance.  Follow all owner’s manual power 
connection instructions.  Installation must be performed by a licensed electrician and all grounding connections must be properly installed.

Message

No message on display.  

Power has been cut off to the spa.

Temperature unknown. 

“Overheat” - The spa has shut down.  One of the 
sensors has detected 118°F/48°C at the heater. 

 

“Overheat” - The spa has shut down.  One of 

the sensors has detected that the spa water is 

110°F/43°C. 

“Ice” - Potential freeze condition detected. 

Spa is shut down.  The sensor that is plugged into 

the Sensor “A” jack is not working. 

Spa is shut down.  The sensor that is plugged into 

the Sensor “B” jack is not working. 

Sensors are out of balance.  If alternating with 

spa temperature, it may just be a temporary 

condition.  If flashing by itself, spa is shut down.

A significant difference between temperature 

sensors has been detected.  This could indicate a 

flow problem.

Persistent low flow problems.  (Displays on the 

fifth occurrence of “ ” message within 24 hours.)  

Heater is shut down, but other spa functions 

continue to run normally.

Possible inadequate water, poor flow, or air 

bubbles in detected in the heater.  Spa is shut 

down for 15 minutes. 

 

Inadequate water detected in heater.  (Displays on 

third occurrence of “ ” message.)  Spa is  

shut down.

The control panel will be disabled until power returns.  Spa 

settings will be preserved until next power up.

After the circ pump has been running for 2 minutes, the 

temperature will be displayed.

DO NOT ENTER THE WATER.  Remove the spa cover 

and allow water to cool.  Once the heater has cooled, reset by 

pushing any button.  If spa does not reset, shut off the power to 

the spa and call your dealer or service organization.

DO NOT ENTER THE WATER.  Remove the spa cover 

and allow water to cool.  At 107°F/42°C, the spa should 

automatically reset.  If spa does not reset, shut off the power to 

the spa and call your dealer or service organization.

No action required.  The pump and blower will automatically 

activate regardless of spa status.

If the problem persists, contact your dealer or service 

organization.  (May appear temporarily in an overheat situation 

and disappear when the heater cools.)

If the problem persists, contact your dealer or service 

organization.  (May appear temporarily in an overheat situation 

and disappear when the heater cools.)

If the problem persists, contact your dealer or service 

organization. 

Check water level in spa. Refill if necessary.  If the water level 

is okay, make sure the pumps have been primed.  If problem 

persists, contact your dealer or service organization.

Follow action required for “ ” message.  Heating capability of 

the spa will not reset automatically; you may press any button 

to reset. 

Check water level in spa.  Refill if necessary.  If water level is 

okay, make sure the pumps have been primed.  Press any button 

to reset, or this message will automatically reset within  

15 minutes.  If problem persists, contact your dealer or service 

organization. 

Follow action required for “ ” message.  Spa will not 

automatically reset.  Press any button to reset.

Meaning

Action Required

Diagnostic Messages