Your system has a 24-hour circ pump.  The circ pump 

and the ozone generator run continuously with the 

exception of shutting off for 30 minutes at a time in 

hot environments.
Temp/Set (80°F - 104°F / 26°C - 40°C)

The start-up temperature is set at 100F°/37°C.  The last 
measured temperature is constantly displayed on the LCD. 

Note that the last measured spa temperature displayed is 
current only when the circ pump has been running for at 
least 2 minutes.

 

To display the set temperature, press the “Temp” or “Set”  
pad once. 
To change the set temperature, press the pad a second time 
before the LCD stops flashing.  Each press of the “Temp” or “Set” 
pad will continue to either raise or lower the set temperature. 
If the opposite direction is desired, release the pad and let the 
display revert to the current water temperature.  Press the pad to 
display the set temperature, and again to make the temperature 
change in the desired direction. 
After three seconds, the LCD will stop flashing and display the 
current spa temperature. 

Note: If there is not a blower on the system, an alternate panel with 
separate "Up" and "Down" buttons in place of a "Set" or "Temp" button 
may be used.  Simply press "Up" or "Down" where a "Temp" or "Set" 
button press is indicated.

Jets

Touch the “Jets” button once to turn pump 1 on or off, and to 
shift between low and high speeds (if equipped).  If left running, 
the low speed of the pump will automatically turn off after  
4 hours, and the high speed will automatically turn off after  
15 minutes.

Blower 

(optional on VS501 or GS501)

This button is used to turn the blower on and off.  If left on, the 
blower automatically turns off after 15 minutes.

Jets 2 

(optional on VS501 or GS501)

If your system has a pump 2 installed instead of a blower, it 
behaves exactly like a blower would.

Light

Press the “Light” button to turn the light on and off.  If left on, 
the light automatically turns off after 4 hours.

(over)

VS500/501 GS500/501 Control Reference Card

Circ Operation

Initial Start-up

When your spa is first actuated, it will go into Priming mode, indicated by “ .” 

 

Please see the M-7 Installation Instruction Manual 

for complete instructions on Power-up and Pump Priming

.  

The Priming mode will last for less than 5 minutes (press "Temp" or 

"Set" to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode.

Mode

Mode is changed by pressing the “Temp” or “Set” button, then 
pressing the “Light” button.

Standard Mode

 is programmed to maintain the desired 

temperature.  Note that the last measured spa temperature 
displayed is current only when the circ pump has been running 
for at least 2 minutes.  “ ” will be displayed momentarily when 
you switch into Standard Mode.

Economy Mode

 heats the spa to the set temperature only 

during filter cycles.  “ ” will display solid when temperature 
is not current, and will alternate with temperature when 
temperature is current.

Sleep Mode 

heats the spa to within 20°F/10°C of the set 

temperature only during filter cycles.  “ ” will display solid 
when temperature is not current, and will alternate with 
temperature when temperature is current.

Preset Filter Cycles

The first filter cycle begins 6 minutes after the spa is energized.  
The second filter cycle begins 12 hours later.  Filter duration is 
programmable for 2, 4, 6, 8 hours or for continuous filtration 
(indicated by “ ”).  The default filter time is 2 hours. 
To program, press “Temp” or “Set,” then “Jets.”  Press “Temp” 
or “Set” to adjust.  Press “Jets” to exit programming.
At the beginning of each filter cycle the blower purges for 30 
seconds; the pump purges for 5 minutes.  The only effect filter 
duration has is: 1) During the filter, the circ pump never turns 
off, and 2) In Economy and Sleep Modes, heating only occurs 
during the filter cycle.

Freeze Protection

If the temperature sensors detect a drop to below 44°F/6.7°C 
within the heater, the pump and blower will automatically 
activate to provide freeze protection.  The equipment stays on 
until 4 minutes after the sensors detect that the spa temperature 
has risen to 45°F/7.2°C or higher.  In colder climates, an 
optional additional freeze sensor may be added to protect against 
freeze conditions that may not be sensed by the standard sensors.  
Aux freeze sensor protection acts similarly except with the 
temperature thresholds determined by the switch and without a  
4-minute delay in turnoff.  See your dealer for details.