background image

Template  56377  10-05-12

6

Manufactured under one or more of these patents.  U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, 

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.                                            © Copyright 2009 Balboa Water Group.

59293-01_59294-01_59295-01_B   05-10-21

Wiring Diagram for Remote Heater Version 

Hardware Setup

OPTIONAL 120VAC CONFIG 

FOR SETUPS 5 - 7 ONLY

WIRING SHOWN IS FOR A 120VAC-ONLY SYSTEM 

FOR A 240V HEATER, MAKE THE FOLLOWING CHANGES:

1. TB1 MUST BE WIRED WHT-1, BLK-2, RED-3

2. MOVE J46 AND J38 WIRES FROM AREA 3 TO AREA 1

3. MOVE J24 JUMPER TO THE 240V POSITION

4. CHANGE F3 FUSE BACK TO 0.1A SLO-BLOW

5. PUT J31 JUMPER ON 2 PINS

A3

A2

SWITCHES #2 & #3 

SHOULD BE SET TO OFF 

WHEN SYSTEM IS 

CONFIGURED AS 120VAC.

OFF

ON

PUMP 1, OZONE, AND CIRC MUST ALL BE 120V IN THIS CONFIGURATION.

WHT

GFCI

BLK

GRN

WITH
GFCI
CORD,
SERVICE
IS 12A
MAX.

16A
SERVICE
REQUIRES
WALL-MOUNT 20A
GFCI / BREAKER.

TB1

1

2

3

1

2

J4

J8

J18

J51

J1

J27

3

J20

J10

J12

J88

J52

J38

 AV

J46

PUMP1

CIRC

OZONE

J24 JUMPERS MUST BE IN

120V POSITIONS AS SHOWN

HERE WHEN HEATER IS 

CONFIGURED AS 120VAC.

J31

J31 JUMPER MUST BE ON

1 PIN WHEN HEATER IS 

CONFIGURED AS 120VAC.

J31

J31 JUMPER MUST

BE ON 2 PINS 

WHEN HEATER IS

CONFIGURED AS 240VAC.

J24 JUMPER 

MUST BE IN

240V POSITION

AS SHOWN HERE 

WHEN HEATER

IS CONFIGURED

AS 240VAC.

120V

120V

240V

J24

120V

120V

240V

J24

F3 0.16A SLO-BLOW

F3 FUSE MUST BE REPLACED BY A

0.16A SLO-BLOW FUSE (SUPPLIED

WITH PACK) WHEN HEATER IS

CONFIGURED AS 120VAC.  SAVE THE

ORIGINAL 0.1A FUSE IN CASE THE

HOMEOWNER WANTS TO CONVERT BACK

TO A 240VAC HEATER.

F3 0.1A SLO-BLOW

F3 FUSE MUST

BE RESTORED

TO THE 0.1A

SLO-BLOW

FUSE WHEN

HEATER IS

CONFIGURED

AS 240VAC.

WHT
BLK
RED

1
2
3

J110

LOCATION 

DEVICE 

VOLTS 

MAX AMPS  FROM 

TO

J9  

2/1-SP PUMP 1

 

240V**  12A MAX 

J46

 

AREA 3

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

J19

 

CIRC PUMP

 

240V**

 

2A MAX

 

 

J21

 

OZONE

 

 

0.5A

 

CIRC AND OZONE LINE 1 CONNECTION

 

J51, J52

 

AREA 2

   

 

J33

TV / AV

120V*

4A

J38

 

AREA 1

J11 & J13

J15

SPA LIGHT

10V

1A

 *FOR 240V AV, MOVE J38 WIRE TO AREA 3

**PUMP 1, CIRC AND OZONE ALL MUST BE THE SAME VOLTAGE.

HEATER

EXPANDER X-B

J3

BLOWER

K1

J6

J2

W12

OPTIONAL EXPANDER X-B PN 59231

LOCATION

DEVICE

VOLTS

AMPS

FROM

TO

FROM

TO

J6

BLOWER

240V

 4A

W12

AREA 3

J3

J55

CONNECT TO J55

CONNECT TO AREA 3

CONNECT TO J5

F5 10A 250V

USED IN 

SETUPS 3 & 4

ONLY

EXPANDER X-P

J4

PUMP 2

K1

J6

J2

W12

OPTIONAL EXPANDER X-P PN 59232

LOCATION

DEVICE

VOLTS

AMPS

FROM

TO

FROM

TO

J6

PUMP 2

240V

12A

W12

AREA 3

J4

J55

CONNECT TO J55

CONNECT TO AREA 3

CONNECT TO J5

USED IN 

SETUPS 1 & 2

ONLY

REMOTE HEATER SOLD SEPARATE

240V 5.5kW (1.4kW @ 120V)

240V 4.0kW (1.0kW @ 120V)

REMOTE HEATER

SENSOR A

SENSOR B

GFCI-PROTECTED CIRCUIT REQUIRED

L2

(RED)

N/A

L1

(BLK)

N

(WHT)

WHT

BLK

RED

GRN

TORQUE RANGE 

FOR TB1: 

27-30IN.LBS.

ALL UNUSED SWITCHES SHOULD BE OFF

8
7
6
5
4
3
2
1

OFF POSITION  

S1 SWITCH #

ON POSITION

*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.

NOTE:  SWITCH A7 MUST BE OFF WHEN USING GRAPHIC
PANELS (TP800, TP900, OR SPATOUCH FAMILY).

NOT ASSIGNED
STANDARD MENUS
STORE SETTINGS*
SPECIAL AMPERAGE RULE OFF
1 MIN HTR COOLDOWN (ELEC)
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 1 HS PUMP W/HTR
TEST MODE OFF

NOT ASSIGNED
SIMPLIFIED MENUS
MEMORY RESET*
SPECIAL AMPERAGE RULE ON
5 MIN HTR COOLDOWN (GAS)
ADD 2 HS PUMPS WITH HEAT
ADD 1 HS PUMP WITH HEAT
TEST MODE ON

INSTEAD OF SETUP

#6, THIS SYSTEM

IS CONFIGURED

IN SETUP #:

 

 

  1 

F POLLING 

1-SPEED  1-SPEED 

NONE 

X-P (PN 59232) 

°F

 2 

NONE 

2-SPEED  1-SPEED 

NONE 

X-P (PN 59232) 

°F

  3 

F POLLING 

1-SPEED 

NONE 

1-SPEED 

X-B (PN 59231) 

°F

 4 

NONE 

2-SPEED 

NONE 

1-SPEED 

X-B (PN 59231) 

°F

  5 

F POLLING 

1-SPEED 

NONE 

NONE 

NONE 

°F

 6 

NONE 

2-SPEED  NONE  NONE 

NONE 

°F

  7 

F POLLING 

NONE 

NONE 

NONE 

NONE 

°F

 SETUP # 

CIRC PUMP 

PUMP 1 

PUMP 2 

BLOWER 

USER-INSTALLED EXPANDER  TEMP SCALE

F4 1A SLO-BLOW

F5 1A SLO-BLOW

F3 0.1A SLO-BLOW

TB1

1

2

3

K5

K1

K2

K4

K3

F6 30A 250VAC

T1

J16

J17

J23

SERIAL

J5

REMOTE

RELAY

BOARD

J28 

AUX FRZ

J35 

J34 

K7

K12

120V

120V

240V

J24

J9

PUMP 1

J19

J21

OZONE

J33

A/V

1

2

J4

J8

J18

J55

J3

J6

J51

J1

J27

J110

J13

HEATER 1

J2

J7

3

J20

J10

J12

J88

J22

ON

S1

J31

J30

J109

J15

LIGHT

J52

J46

J38

J11

HEATER 2

1

8

J56

J57

CIRC

TP (MAIN) PANELS

J34 OR J35

FOR SUPPLY CONNECTIONS, 

USE CONDUCTORS SIZED ON THE 

BASIS OF 60°C AMPACITY BUT 

RATED MINIMUM OF 90°C.

USE COPPER CONDUCTORS ONLY.

EMPLOYER UNIQUEMENT 

DES CONDUCTEURS DE CUIVRE.  

#6 AWG MIN. WIRE= 90°  

CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.

A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM 

THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE 

INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.

TOTAL OUTPUT AMP DRAW NOT TO 

EXCEED MAX INPUT RATING OF SPA

USE EARTH GROUND CONNECTIONS 

AS INDICATED INSIDE SYSTEM ENCLOSURE

EXPANDER BOARD MOUNTING HARDWARE
IS PRE-INSTALLED ON THIS MODEL.

NO EXPANDER BOARD IS USED
IN SEtUPS 5 - 7.

TORQUE RANGE 

FOR HEATER 

CONNECTIONS:  

30 TO 35

IN. LBS. 

05-05-21

WIFI

TRANSCEIVER

J34 OR J35

NOTE:  SWITCH A7 SHOULD 
BE OFF IF USING WIFI, 
SINCE WIFI DOESN’T SUPPORT 
SIMPLIFIED MENUS.

BP100UX PN 59295-01

APPLY NEXT TO MAIN WIRE DIAGRAM 

>>>

<<<

APPLY NEXT TO MAIN WIRE DIAGRAM

<<<

APPLY NEXT TO MAIN WIRE DIAGRAM

Содержание BP100UX

Страница 1: ...UX hex Configuration Signature E68167C4 Eng Project Number 5353 Control Panels See later pages for more information spaTouch 2 Any version version 2 0 or later required for bba 2 fully integrated functionality Icon spaTouch Any version version 3 36 or later required for bba 2 fully integrated functionality Menued spaTouch Any version version 2 8 or later required for bba 2 integrated functionality...

Страница 2: ...em which is a combination of the BP100G1 BP100G2 and BP100G3 systems into one model with an optional user insstalled expander board the expander board mounting hardware is pre installed 59293 01 59294 01 59295 01 5353 02 17 21 BWG Update to new system board shape System Revision History bba bba 2 Balboa Bluetooth Amp connection is documented seperately bba is integrated into graphic display panels...

Страница 3: ...ground NOTE The above 120V spec is only when using a wall mount GFCI breaker If using a GFCI cord the breaker is 15A and so the service is limited to 12A BP systems automatically detect 50Hz vs 60Hz However power frequency 50Hz vs 60Hz is just one of many differences between North American UL and CE power and it is because of these other differences that different BP systems must be used for UL vs...

Страница 4: ... in Setups 1 3 5 Unused in Setup 7 Pump 2 240VAC 1 Speed 12A max 15 minute timer Used in Setups 1 2 only Blower 240VAC 1 Speed 4A max 15 minute timer Used in Setups 3 4 only Circ Pump 240VAC 1 Speed 2A max Programmable Filtration Cycles Polling This is the heater pump in Setups 1 3 5 7 Must deliver 20 GPM through heater Ozone 240VAC 5A max Slaved to Circ Pump in Circ Setups and to Pump 1 Low in No...

Страница 5: ... J5 CONNECT TO J55 CONNECT TO AREA 3 CONNECT TO J5 F5 10A 250V USED IN SETUPS 3 ONLY EXPANDER X P J4 PUMP 2 K1 J6 J2 W12 OPTIONAL EXPANDER X P PN 59232 LOCATION DEVICE VOLTS AMPS FROM TO FROM TO J6 PUMP 2 240V 12A W12 AREA 3 J4 J55 CONNECT TO J55 CONNECT TO AREA 3 CONNECT TO J5 USED IN SETUPS 1 2 ONLY SENSOR A SENSOR B 5 5 kW HEATER 1 4kW 120V 240V 5 5 kW 1 4kW 120V GFCI PROTECTED CIRCUIT REQUIRED...

Страница 6: ...ONNECT TO AREA 3 CONNECT TO J5 F5 10A 250V USED IN SETUPS 3 ONLY EXPANDER X P J4 PUMP 2 K1 J6 J2 W12 OPTIONAL EXPANDER X P PN 59232 LOCATION DEVICE VOLTS AMPS FROM TO FROM TO J6 PUMP 2 240V 12A W12 AREA 3 J4 J55 CONNECT TO J55 CONNECT TO AREA 3 CONNECT TO J5 USED IN SETUPS 1 2 ONLY REMOTE HEATER SOLD SEPARATE 240V 5 5kW 1 4kW 120V 240V 4 0kW 1 0kW 120V REMOTE HEATER SENSOR A SENSOR B GFCI PROTECTE...

Страница 7: ... SPEED X B PN 59231 F 5 FILTERS POLLING 1 SPEED NONE NONE NONE F 6 NONE 2 SPEED NONE NONE NONE F 7 FILTERS POLLING NONE NONE NONE NONE F J22 FOR SUPPLY CONNECTIONS USE CONDUCTORS SIZED ON THE BASIS OF 60 C AMPACITY BUT RATED MINIMUM OF 90 C USE COPPER CONDUCTORS ONLY EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE 6 AWG MIN WIRE 90 GFCI SIGHT FROM THE TOTAL OUTPUT AMP DRAW NOT TO EXCEED MAX INPUT RA...

Страница 8: ...Change Software Setups While in Test Mode press the indicated icons to move from screen to screen ON 1 10 S1 Changing Software Setups with spaTouch Icon Driven Panels Once on the Setup Selection screen press the Up or Down icon to select the desired Setup Number then press the Check Mark icon to confirm and to have the spa restart After the system restarts you may see a message that The settings h...

Страница 9: ...is running move DIP Switch 1 on S1 on the Main circuit board to ON The system will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer Changing the Setup may require wiring changes as well Changing Software Setups with TP800 TP900 spaTouch Menued Panel ...

Страница 10: ...uit board to ON The system will enter Test Mode Moving DIP Switch 1 to OFF will exit Test Mode Software Setups Under the TEST Menu the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer Changing the Setup may require wiring changes as well You will have 1 minute to complete the setup change after you manually exit Priming Mode Once familiar with the pro...

Страница 11: ...lace a circuit board or system and needs to change the Setup on a replacement part while in the field NOTE Changing the Setup may require wiring changes as well refer to the wiring diagram or wiring diagram addendum THIS SYSTEM IS CONFIGURED AS SETUP Indicates Flashing or Changing Segment Key A temperature button used for Action Light or dedicated Choose button depending on control panel configura...

Страница 12: ...ent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group 59293 01_59294 01_59295 01_B 05 10 21 Expansion Features Control Connection Default Fuse Relay 1 J5 in Setups 5 7 None As Manufactured Relay 1 J5 in Setups 1 2 1 Speed Pump 2 None uses main board 30A fuse Relay 1 J5 in Setups 3 4 1 Speed Blower 10A Equipment Expan...

Страница 13: ... the spa is powering up to restore factory settings as determined by software configuration A2 and A3 work in combination to determine the number of high speed devices and blowers that can run before the heater is disabled i e A2 and A3 in the ON position will allow the heater to operate with up to 3 high speed pumps or two HS Pumps and Blower running at the same time Heat is disabled when the fou...

Страница 14: ...ture must be enabled in software as well J30 Do Not Use J31 Jumper on 1 pin when heater voltage is 120V Jumper on 2 pins when heater voltage is 240V J24 Jumper on center two pins 240V when heater voltage is 240V Two Jumpers installed one on left 2 pins and one on right 2 pins 120V when heater voltage is 120V Warning Setting DIP switches or jumpers incorrectly may cause abnormal system behavior and...

Страница 15: ...p2 59231 X B for Blower HEATER s Heater 58421 5 5kW 800Inc for integral heater only 58426 4 0kW 800Inc for integral heater only Temp Sensor Kit 30344KIT 12 inch sensor for integral heater only 30382KIT 24 inch sensor for integral heater only FUSES Part Number Amperage Location 30136 30A F6 26983 1A F4 F5 on main board 24514 0 1A F3 when using 240V heater 26982 0 16A F3 when using 120V heater 30122...

Страница 16: ...y General Pump Timer 15 Minutes Blower Timer 15 Minutes Mister Timer 15 Minutes Light Timer 240 Minutes Circ when enabled Programmable Polling Circ Pump can be set with the following functions 24 hr 24 hr w 3 shutoff Acts like P1 Low filters polls etc Requires a single speed P1 Cleanup Cycle 30 Minutes Between 30 and 240 minutes 30 Minutes or OFF Cleanup as Preference setting Yes Yes No N A Ozone ...

Страница 17: ... required for default settings choose a desired C value that after rounding cor responds to a Fahrenheit value C 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 F 39 41 43 45 46 48 50 52 54 55 57 59 61 63 64 66 68 70 72 C 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 F 73 75 77 79 81 82 84 86 88 90 91 93 95 97 99 100 102 104 Hi Range Min Set Temp 80 F Between 50 and 80 F 1 F Hi Range Ma...

Страница 18: ... Format 12 Hour 12 Hour 24 Hour N A Filter 1 Start Hour 20 00 8 00 PM 00 00 to 23 00 1 Hour Filter 1 Duration 2 Hours Between 15 Min and 23 45 15 Minutes or continuous Filter Cycle 2 Default OFF OFF ON N A Filter 2 Start Hour 08 00 8 00 AM 00 00 to 23 00 1 Hour Filter 2 Duration 15 Minutes Between 15 Min and 23 45 15 Minutes or Continuous or Disabled Light Cycle Disabled Disabled Enabled N A Light...

Страница 19: ...nt Reminders Shown Yes Yes No N A Check pH OFF See Reminder Period Note 1 Days Check Sanitizer OFF See Reminder Period Note 1 Days Clean Filter 30 Days See Reminder Period Note 1 Days Test GFCI OFF See Reminder Period Note 1 Days Drain Water 100 Days See Reminder Period Note 1 Days Change Cartridge OFF See Reminder Period Note 1 Days Clean Cover OFF See Reminder Period Note 1 Days Treat Wood OFF S...

Страница 20: ... run on high speed together Blower can be allowed or suppressed when number of pumps selected is reached No Limitation does not restrict pump or blower operation DIP Switch 5 is used to choose Special Amperage Rule 1 or 2 Drain Mode Disabled Disabled Enabled N A Demo Mode Disabled GFCI Trip Enabled Disabled Enabled N A Automatic GFCI Test Disabled Disabled 1 7 Days 1 Day When GFCI Test is Enabled ...

Страница 21: ...t Invert Circ Icon 5 Invert Invert Invert Invert Circ Icon Undefined Undefined 6 Circ Icon Undefined Circ Icon Undefined Undefined Undefined Undefined 7 Undefined Undefined Undefined Undefined Undefined Undefined Undefined 8 Undefined Undefined Undefined Undefined Undefined Undefined Undefined 9 Undefined Undefined Undefined Undefined Undefined Undefined Undefined 10 Undefined Undefined Undefined ...

Страница 22: ...con Undefined A6 Circ Icon Undefined Circ Icon Undefined Undefined Undefined A7 Undefined Undefined Undefined Undefined Undefined Undefined A8 Undefined Undefined Undefined Undefined Undefined Undefined A9 Undefined Undefined Undefined Undefined Undefined Undefined A10 Undefined Undefined Undefined Undefined Undefined Undefined A11 N A N A N A N A N A N A A12 N A N A N A N A N A N A A13 Undefined ...

Страница 23: ...dian Patent 2342614 Australian patent 2373248 other patents both foreign and domestic applied for and pending Copyright 2009 Balboa Water Group 59293 01_59294 01_59295 01_B 05 10 21 TP800 Panel Configuration Spa Screen Shortcuts Screen A2 A3 A4 A5 A6 A7 A8 A9 A10 A16 A15 A14 A13 B1 B1 B3 B3 B4 B4 B2 B2 A13 A14 A15 A16 Note Buttons 11 and 12 are not used in this configuration Button 1 is fixed ...

Страница 24: ...oa Water Group 59293 01_59294 01_59295 01_B 05 10 21 TP600 Panel Configuration Button Layout Table Button Setups 1 2 Setups 3 4 Setups 5 6 1 Jets 1 Jets 1 Jets 1 2 Jets 2 Blower Undefined 3 Invert Invert Invert 4 Up Up Up 5 Light 1 Light 1 Light 1 6 Down Down Down LED 1 Jets 1 Jets 1 Jets 1 LED 2 Jets 2 Blower Undefined LED 3 Light 1 Light 1 Light 1 LED 4 Heat On Heat On Heat On TP600 Panel Config...

Страница 25: ...ure Up 2 Jets 1 Jets 1 Jets 1 Down 3 Light 1 Light 1 Light 1 Light 1 4 Jets 2 Blower Undefined Undefined LED 1 Heater ON Heater ON Heater ON Heater ON LED 2 Jets 1 ON Jets 1 ON Jets 1 ON Undefined LED 3 Light ON Light ON Light ON Light ON LED 4 Jets 2 Blower Undefined Undefined Button Layout Table for TP400W TP200W Button All Setups 1 Up 2 Down 3 Light 1 4 Jets 1 LED 1 Heater ON LED 2 Undefined LE...

Отзывы: