26
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
2013-06-22
TEST IS WITH POWER OFF
TROUBLESHOOTING HEATER POSTS RESISTANCE TO HEATER HOUSING
VERIFY THAT THERE IS NO HEATER “LEAKAGE”
Measure resistance from a heater post to the
heater housing
Verify there is NO continuity from the heater post
to the heater housing or heater current collector
connection. The meter reading shown is OL,
indicating infinite resistance.
Verify there is NO continuity from the heater post to
the ground/earth. On the resistance scale, the a digital
meter should read OL (indicating infinite resistance).
Troubleshooting Heater Posts Resistance to Heater Housing
Locate the heater connector.
Disconnect the connector by depressing the tab.
Pull the connector straight out.
Release tab
Release tab