Fixed-fuction DIP Switches
A1
Test Mode (normally Off).
A2
In “ON” position, add one high-speed pump (or blower) with Heater.
A3
In “ON” position, add two high-speed pumps (or 1 HS Pump and Blower) with Heater.
A5
In “ON” position, enables Special Amperage Rule B. See Special Features section under Configuration Options for functionality with your system.
In “OFF” position, enables Special Amperage Rule A.
A6
Persistent memory reset (Used when the spa is powering up to restore factory settings as determined by software configuration).
A2 and A3
work in combination to determine the number of high-speed devices and blowers that can run before the heat is disabled. i.e. A2 and A3 in the ON position will
allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same time. Heat is disabled when the fourth high-speed pump or
blower is turned on.
Note:
A2/A3 all off = No heat with any high-speed pump or blower.
Assignable DIP Switches
A4
In “ON” position, enables a 5-minute cooldown for some gas heaters (Cooling Time B).
In “OFF” position, enables a 1-minute cooldown for electric heaters (Cooling Time A).
A7
In “ON” position, Simplified Menus on TP400/TP500/TP600. Do not use graphic panels (TP800, TP900, or spaTouch™ family) with Simplified Menus.
In “OFF” position, Regular Menus on TP400/TP500/TP600. This setting is compatible with all panels.
A8
In “ON” position, 3-Phase Special Amperage Rule is enabled.
In “OFF” position, 3-Phase Special Amperage Rule is disabled.
Undesignated switches are not assigned a function.
DIP Switch Functions
ON
1
8
S1