Template 56377 10-05-12
10
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2009 Balboa Water Group.
59267_59268_A 05-13-19
Changing Software Setups with TP600 / TP400 Continued
Again,
You will have 1 minute
to complete the setup change after you manually exit Priming Mode.
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue to press Warm until the diplay
shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup number is showing, press Light once, and the system will reset,
using the newly-selected Setup from that point on.
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very important to any service
person in the future who may need to replace a circuit board or system and needs to change the Setup on a replacement part while in the field.
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum.
THIS SYSTEM IS
CONFIGURED AS
SETUP #
Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time - varies depending on function
05/12/09
Main Menus with Test Mode (S1 ON) Details
SET
SET
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
Several Setups can
exist in in this string
A dash (--) indicates the current Setup.
SET
SET
SET
SET
SET
SET
SET
While the Set Temperature is
still flashing, press Light
TEST will now appear in
the LCD first.
SET
RANGE
Main Screen
READY
RANGE FLTR1
Main Screen
READY
RANGE FLTR1
SET
Approx.
5 sec.
or
Approx.
5 sec.
or
SET
SET
SET
SET
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
Displays Fault Log
*If the Control Panel does not have a Warm (Up) button, but
rather a single Temp button, use the Temp button in place
of the Warm button in the instruction above. (The flow chart
assumes a single Temperature Button.)
Note: The Timeouts and Spa O/H
selections should NEVER be changed.
They are for safety agency testing
purposes only.