EL/GL SERIES (Mach 3) CONTROL WITH ML240 PANEL

The ML240 panel can be used as a main panel 
with the EL2000 and EL1000 systems, but only as a 
remote/additional panel for the EL8000 and EL5000 
systems. This user guide all features that are available. 
Your spa may not respond as described in this document 
as specific operation varies by system and equipment 
used. If your spa is not fully equipped, the panel 
buttons on your spa control may not be laid out as 
shown. Functions not accessible by this panel may be 
accessible by a larger panel such as the ML700 or the 
ML900. One such example: This panel can be used 
with EL2000 systems equipped with two pumps plus a 
blower, but the blower cannot be controlled with this 
panel unless the system does not have a pump 2. In 
this case, the blower can be controlled with an optional 
auxiliary panel.

The pump responsible for heating and filtration (pump 1
low on non-circ systems, or the circ pump on circ 
systems) will be referred to simply as the pump.

Timeouts refer to a preset length of time that a 
function is programmed to operate before shutting off 
automatically. Certain conditions (filters or freeze) can 
cause a function to operate longer, while faults can 
cause a function to operate for a shorter length of time. 
The system keeps track of timeouts regardless of other 
conditions occurring.

In multi-button sequences, if buttons are pressed too 
quickly in sequence, they may not register.

Table of Contents

EL/GL SERIES (Mach 3) CONTROL   . . . . .   1
Initial Start-up  . . . . . . . . . . . . . . . . . . . . .   1
Temp Set   . . . . . . . . . . . . . . . . . . . . . . . .   2
Temp  . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Standby Mode  . . . . . . . . . . . . . . . . . . . . .   2
Jets . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Jets 2   . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Blower  . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Circ Pump . . . . . . . . . . . . . . . . . . . . . . . .   2
Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
Ozone . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
Clean-up Cycle  . . . . . . . . . . . . . . . . . . . .   3

Freeze Protection   . . . . . . . . . . . . . . . . . .   3
Locking Features  . . . . . . . . . . . . . . . . . . .   3
Preset Filter Cycles   . . . . . . . . . . . . . . . . .   3
Displaying Information About Your Spa  . .  3
User Preferences  . . . . . . . . . . . . . . . . . . .   4
Editing User Preferences  . . . . . . . . . . . . .   4
Periodic Reminder Messages  . . . . . . . . . .   5
GFCI Protection . . . . . . . . . . . . . . . . . . . .   5
GFCI Trip Test Procedure   . . . . . . . . . . . .   5
Diagnostic Messages  . . . . . . . . . . . . . .   6-7
Optional Auxiliary Panels   . . . . . . . . . . . .   8
Basic Installation Guidelines   . . . . . . . . . .   9
CSA Compliance  . . . . . . . . . . . . . . . . . . .  9

Page 1

Initial Start-up

When your spa is first actuated, it will go into Priming 
mode (after displaying some configuration information). 

Please see the M-7 Installation Instruction Manual for 
complete instructions on Power-up and Pump Priming.

The Priming mode will last for up to 4 minutes and 
then the spa will begin to heat and maintain the water 
temperature in the Standard mode. You can exit Priming 
mode early by pressing “Temp”.

Содержание ML240

Страница 1: ...Light Temp Jets Aux Light Temp Jets Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL...

Страница 2: ......

Страница 3: ...utting off automatically Certain conditions filters or freeze can cause a function to operate longer while faults can cause a function to operate for a shorter length of time The system keeps track of...

Страница 4: ...Mode Pressing Temp followed by Aux or Jets 2 or Blower will turn off all spa functions temporarily This is helpful when changing a filter Pressing any button exits Standby mode On some systems the Jet...

Страница 5: ...the temperature thresholds determined by the switch See your dealer for details Locking Features If this panel is used as the main panel locking features will not be available If this panel is used as...

Страница 6: ...factory default When set to through the number is the address see your Dolphin II manual for details Editing User Preferences View the setting The left two characters before the decimal point tell you...

Страница 7: ...reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets and then pressing the Temp button until you...

Страница 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and a...

Страница 9: ...solid on the display when the temperature is not current will alternate with the temperature when the temperature is current Operates the same as Standard mode then reverts to Economy mode after 1 hou...

Страница 10: ...operation med hi off or 3 speed operation lo med hi off If left on the blower will automatically turn off after a timeout period Fiber optional on some systems If a fiber optic light with wheel is in...

Страница 11: ...nnect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitab...

Страница 12: ...o not attempt service of this control system Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a lice...

Отзывы: