55069_02-97_A
Ozone Connections
U4
F4
J12
K1
K12
K13
K11
W13
W7
T1
W9
G
R
B
W
G
N
W1
J97
ADCM
J1
J9
J3
J
5
12V-A
J2
J96
J37
AUX. P
ANELS
MAIN P
ANELS
E.GND
F10
REMOTE
J69
J20
FUSE 10A 2
5
0V
FUSE 3A 2
5
0V
J71
J70
J10
J39
TST
EXT
SENS. A
SENS. B
VAC
AUX. F
CFG
J80
SWITCHBANK A
P1-LO
24HR
P1 LO
ALRM
1
2
3
12V
-B
J6
J8
5
J86
J9
5
BLK
1
1
2
2
3
3
GN
F1
Use this slot for the leftover Red conductor
Line - Black conductor
Balboa Ozone connector configuration for 120V 60Hz
Ground (Green) conductor
Flat sides of sockets as shown
Common - Install the White conductor here for 120V ozone
Use this slot for the leftover White conductor
Line - Black conductor
Balboa Ozone connector configuration for 240V 60Hz
Ground (Green) conductor
Common - Install the Red conductor here for 240V ozone
B
G
B
G
Use this slot for the leftover conductor
Line - Black conductor
Ground (Green) conductor
Common - Red for 240V or
White for 120V ozone (See W13 wire)
W13 wire determines voltage
Ozone Connection Voltage:
Ozone Connection #1 - Using the J9 On-board Connector
• The EL1000 Circuit Board to deliver the desired voltage to the on-board connector (J9). Connect the W13 wire to J86
AND the wire from J95 to either White AC (120V) or Red AC (240V) to change the voltage setting if required.
• J3 should be set on pins 1 and 2 to operate the Ozone Generator with Pump 1 Low.
Ozone Connection #2 - Using X-03 Expansion Board
• An Ozone generator connected to the X-03 expansion board MUST be the same voltage as the circ pump connected.
• J3 should be set on pins 2 and 3 to provide continuous fused power to the X-03 expansion board from the J9 connector
on the main PCBA.
Balboa Ozone Generator:
The pin next to ground determines voltage on these connectors.
If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured
correctly, but should be compared to the illustration below.
If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the
green ground wire as described below.
Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with
your Balboa Account Manager for information on purchasing a pin-removal tool.