55069_02-97_A

EL1001 Mach 3 Hot Sheet

55069_02-97_A.pdf   11/16/2006

Template used: 40572-v28_A.pdf 11/09/2006

9XcYfX@ejkild\ekj

Jpjk\dGE,,'-0$')

System Model # E1P-EL1001M3-DCAH
Software Version # 28
EPN # 2130

Base PCBA - PN 54389-02
PCB EL1000 – PN 22952 Rev B or C

Base Panels
ML400 – PN 52684

Содержание E1P-EL1001M3-DCAH

Страница 1: ...55069_02 97_A pdf 11 16 2006 Template used 40572 v28_A pdf 11 09 2006 9XcYfX ejkild ekj Jpjk d GE 0 System Model E1P EL1001M3 DCAH Software Version 28 EPN 2130 Base PCBA PN 54389 02 PCB EL1000 PN 22952 Rev B or C Base Panels ML400 PN 52684 ...

Страница 2: ...al Options Full Feature Dolphin Remote and Spa only Dolphin Remote Spa Monitor Connects to Main Panel terminal J70 or J71 IR or RF Dolphin Receiver Module Connects to Remote terminal J20 Ozone Generator Connects to terminal J9 MoodEFX Lighting Connects to Spa Light terminal J12 FiberEFX Lighting Connects to Spa Light terminal J12 Stereo System Connects to A V terminal J2 U4 K1 K12 W13 W9 G J2 J96 ...

Страница 3: ...his must be corrected before you can reset Persistent Memory The switch numbers jumpers or configuration settings displayed after are ones with which the system has found a configuration problem For example would mean that the combination of how you ve set A5 and how you ve set B2 is not supported on this system would mean that there is a problem with jumper J99 would mean that the combination of ...

Страница 4: ... 2 Speed 240V Circ Pump 240V Blower 120V Ozone 12V Spa Light 240V 5 5kW Heater ML400 Main Panel 120 Volt Connections 240 Volt Connections Black AC Jumpers 12 Volt Connections Relay Control Wires Wiring Color Key Typically Line voltage Typically Line voltage for 2 speed pumps Neutral Common Ground Note flat sides in connector Connector Key WARNING Main Power to system should be turned OFF BEFORE ad...

Страница 5: ...F position disables Pump 2 A 9 In ON position DO NOT USE See note below In OFF position no Circ Pump A 10 In ON position Blower enable when Pump 2 is disabled A8 must be Off In OFF position Blower disabled A 11 In ON position DO NOT USE See note below In OFF position Pump 1 is two speed A 12 Persistent memory reset normally off used when spa is powering up Jumpers J3 Jumper on Pins 1 and 2 will po...

Страница 6: ...3 J19 J43 U4 J48 J28 BLK AC J11 J8 J42 TB1 CLASS G FUSE 30A F7 F4 J12 K1 K12 K4 K13 K8 K6 K11 W13 W7 F2 RED AC J53 J54 J55 J26 J25 K7 T1 HTR2 HTR1 FUSE 0 3A 250V W9 G R B W G R B W G R B W W1 J97 ADCM J1 J9 J3 J5 12V A J2 J96 J37 Balboa EL1000 Mach III P N 22952 REV C COPYRIGHT 2005 MADE IN U S A AUX PANELS MAIN PANELS E GND F10 REMOTE J69 J20 FUSE 10A 250V FUSE 3A 250V J71 J70 J10 J39 TST EXT SEN...

Страница 7: ... to J9 pin 1 6 A on main PCBA Circ Pump and Ozone must be same voltage PN 53426 Document PN 40603 D G R B W G R B W J6 J7 J4 J5 J2 W12 K1 G R B W J6 J4 J2 W12 K1 PN 53310 PN 53544 PN 53681 X P231 Can replace the X P in cases where branch circuit protection is needed for high amperage devices that would over burden power input fuse F7 2 A on the main PCBA This allows J6 on the X P231 to connect dir...

Страница 8: ...nnector The EL1000 Circuit Board to deliver the desired voltage to the on board connector J9 Connect the W13 wire to J86 AND the wire from J95 to either White AC 120V or Red AC 240V to change the voltage setting if required J3 should be set on pins 1 and 2 to operate the Ozone Generator with Pump 1 Low Ozone Connection 2 Using X 03 Expansion Board An Ozone generator connected to the X 03 expansion...

Страница 9: ...55069_02 97_A Panel Configurations Heat Jets Aux Temp Light ML400 PN 52684 with Overlay PN 11345 Connects to Main Panel terminal J70 or J71 N ON T IME C APABLE ...