Balanced Audio Technology VK-40 Скачать руководство пользователя страница 18

 

18

 

 

Five Year Limited Warranty

  

Terms and Conditions 
 
1.  Limited Warranty
 
Upon  receipt  of  the  attached  warranty  registration  form,  Balanced  Audio  Technology  warrants  the  purchased 
product to be free from manufacturing, materials, and workmanship defects for five years from date of original 
purchase,  excepting  vacuum  tubes,  subject  to  the  following  conditions.    Failure  to  return  the  enclosed 
registration form within 30 days from original purchase will result in a warranty period of one year from 
the date of manufacture. 
 
2.  Limited to Original Purchaser
 
This warranty is for the sole benefit of the original purchaser of the covered product, and may not be transferred 
to a subsequent purchaser of the product. 
 
3.  Conditions and Limitations 
This warranty is subject to certain conditions and limitations, as follows.  This warranty is void and inapplicable 
if the product has not been used in accordance with the instructions found elsewhere in this manual, or if it has 
been  misused  or  abused,  damaged  by  accident  or  neglect,  or  in  transport once in possession of the purchaser.  
The  warranty  is  also  void  if  the  product  has  been  repaired,  modified,  or  tampered  with  by  anyone  other  than 
Balanced Audio Technology or its specifically authorized agents.   
 
4.  Remedy 
If  this  product  contains  a  materials,  manufacturing,  or  workmanship  defect  that  cannot  be  repaired  at  the 
dealership where the product was purchased, it must be packed in original packaging and returned to Balanced 
Audio Technology via insured freight, at the owners expense.  If replacement packaging materials are required, 
they  will  be  supplied  by  the  factory  at  a  nominal  charge.    Returned  products  must  be  accompanied  by  a 
written  description  of  the  defect,  and  a  return  authorization  number  (available  from  the  factory  via 
phone  or  fax).
    Upon  receipt  of  defective  product,  Balanced  Audio  Technology  agrees  to  repair  the  product 
without charge for parts (except vacuum tubes if the unit is more than one year old), or labor.  The product will 
then  be  returned  via  prepaid,  insured  freight,  with  carrier  at  the  sole  determination  of  Balanced  Audio 
Technology. This constitutes the purchasers sole remedy.   

 

5.  Design Changes 
Balanced  Audio  Technology  reserves  the  right  to  modify  its  products  or  change  specifications  at  any  time 
without obligation or liability to previous purchasers. 
 
6.  Miscellaneous 
Any  implied  warranties  relating  to  the  above  product  shall  be  limited  to  the  duration  of  this  warranty.    This 
warranty  does  not  extend  to  any  incidental  or  consequential  costs  or damages to the purchaser. This warranty 
gives you specific legal rights.  You may also have other rights which vary from state to state. 
 

Содержание VK-40

Страница 1: ...____________________________ Address _______________________________________ _______________________________________ IMPORTANT NOTE In order to receive the full five year product warranty please mail...

Страница 2: ...2 VK 40 Solid State Balanced Stereo Preamplifier Owner s Manual 1300 First State Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Страница 3: ...lection 7 VOLUME knob 7 DISPLAY format 8 FUCTION button 8 DISPLAY ON OFF function 9 MUTE function 9 VK 40 PROGRAMMABLE FUNCTIONS 10 Parameter Definitions 11 PROGRAMMING THE VK 40 11 BALANCE adjustment...

Страница 4: ...re DO NOT operate with the cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuse with anything other than the same type and rating as supplied by the...

Страница 5: ...negative For the VK 40 use either the Main 1 or Main 2 XLR Output for connection to your power amplifier Both yield equivalent results Single Ended Components Single ended components have RCA connect...

Страница 6: ...On it will automatically go through a gentle power on sequence This sequence takes 50 seconds during which time the display and the Standby LED will be flashing indicating the status of the unit 1 Th...

Страница 7: ...ime the signal cables are changed or any other system configuration changes are being made This function is also accessible via the VK R3 remote control LED OFF Unit in Play mode LED ON Output Muted I...

Страница 8: ...nels are identical 4 Volume setting three digits with the full range of 000 to 140 See programming section on Maximum Volume Setting FUNCTION Button This button puts the unit in its programming mode I...

Страница 9: ...ton goes ON when the unit is in MUTE state To MUTE the VK 40 depress the MUTE button located on the right side of the front panel Depressing this button again will return the unit to its normal operat...

Страница 10: ...ls the Function button and Volume knob or corresponding remote control buttons Function and Volume Up Down buttons Every unit comes from the factory with a default set of parameters stored in its memo...

Страница 11: ...udio Video installations With this flexibility it is possible for example to set the CD input to be Stereo and Non Inverting while the Phono input would be Mono and Inverting PROGRAMMING THE VK 40 NOT...

Страница 12: ...input is used as the reference Let s presume that the PH1 input the weaker source is then programmed to play at 20 counts higher Its volume offset will then read 20 The user can later select the PH1 i...

Страница 13: ...d STEREO Use the volume knob to set the condition to STEREO MONO or LAST Exit the programming mode by pressing and holding the Function button NOTE In the LAST mode the state of the Phase switch will...

Страница 14: ...see below UNITY gain for the VK 40 preamplifier correspond to the following volume setting CNTS display mode 100 Counts DBU 00 0dB DBM 20 0dB Exit the programming mode by pressing and holding the Func...

Страница 15: ...ource The examples may include CD 2 DVD1 JOHN VKD5 MARY BOB1 etc To program the input name do the following Select the desired input Press the Function button eight times The first character of the in...

Страница 16: ...te allowing for more flexible control when large changes in volume are required Mute Pressing this button will cause the MUTE function in the VK 40 to toggle between ON and OFF states The Mute LED on...

Страница 17: ...STANDBY state simply press the POWER button on the VK R3 remote control transmitter Fuse Protection A blown fuse in the VK 40 is an indication of a serious problem If a replacement fuse fails as well...

Страница 18: ...uthorized agents 4 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the dealership where the product was purchased it must be packed in origin...

Отзывы: