VK-32SE PROGRAMABLE FUNCTIONS 

 
The VK-32SE programming functions allow the user to optimize the unit configuration for any 
particular system set up.  The flexible programming facility defines each signal input with a group 
of user-selectable parameters that are then stored in the unit’s memory.  Every time a particular 
input is selected, its unique combination of parameters is loaded into the operating memory.  
Programming is easy and is accomplished through using just two front panel controls -: the 
Function button and Volume knob, or corresponding remote control buttons (Function and 
Volume Up/Down buttons). 
 
Every unit comes from the factory with a default set of parameters stored in its memory.  This set of 
parameters is usable for many applications.  The default set includes the following parameters: 
 

BALANCE     

 

 

ZERO 

 
RELATIVE VOLUME  

 

ZERO 

 

 

PHASE 

 

 

 

Non-Inverting 

 
MONO/STEREO 

 

 

STEREO 

 
MAXIMUM VOLUME 

 

140 

 
FIXED GAIN   

 

 

OFF 

 
DISPLAY  

 

 

 

COUNTS 

 
INPUT NAMES  

 

 

TAPE 

TUN 

CD1 

AUX1 

AUX2 or PH1 if the phono card is installed 

 
 
The user may at any time, configure the unit to a particular set of system requirements.  For 
example, input names can be changed to reflect a given system’s source configuration. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание VK-32SE

Страница 1: ...______________________________ Address _______________________________________ _______________________________________ IMPORTANT NOTE In order to receive the full five year product warranty please mai...

Страница 2: ...2 VK 32SE Vacuum Tube Balanced Stereo Preamplifier Owner s Manual 1300 First Stat Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Страница 3: ...unit In its standard configuration the VK 32SE current sources use the Russian 6C19 tubes That tube is basically a miniature version of the famous 6C33 tube and provides in our view the best combinat...

Страница 4: ...ure WARNING The following procedure should only be performed by qualified personnel To change the current source 1 Turn the unit OFF and wait at least 5 minutes to allow the tubes to cool down and the...

Страница 5: ...tion 9 VOLUME knob 9 DISPLAY format 10 FUCTION button 10 DISPLAY Brightness function 11 MUTE function 11 VK 32SE PROGRAMMABLE FUNCTIONS 12 Parameter Definitions 13 PROGRAMMING THE VK 32SE 13 BALANCE a...

Страница 6: ...re DO NOT operate with the cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuse with anything other than the same type and rating as supplied by the...

Страница 7: ...ve For the VK 32SE use the Main 1 XLR Output for connection to your balanced power amplifier The Output 2 is configured as an RCA connector output Single Ended Components Single ended components have...

Страница 8: ...SE On it will automatically go through a gentle power on sequence This sequence takes 50 seconds during which time the display and the Standby LED will be flashing indicating the status of the unit 1...

Страница 9: ...me the signal cables are changed or any other system configuration changes are being made This function is also accessible via the VK R3 remote control LED OFF Unit in Play mode LED ON Output Muted IN...

Страница 10: ...nnels are identical 4 Volume setting three digits with the full range of 000 to 140 See programming section on Maximum Volume Setting FUNCTION Button This button puts the unit in its programming mode...

Страница 11: ...ack ON MUTE Function The VK 32SE has two mute modes manual and automatic The blue LED above the Mute button goes ON when the unit is in MUTE state To MUTE the VK 32SE depress the MUTE button located o...

Страница 12: ...rols the Function button and Volume knob or corresponding remote control buttons Function and Volume Up Down buttons Every unit comes from the factory with a default set of parameters stored in its me...

Страница 13: ...udio Video installations With this flexibility it is possible for example to set the CD input to be Stereo and Non Inverting while the Phono input would be Mono and Inverting PROGRAMMING THE VK 32SE N...

Страница 14: ...input is used as the reference Let s presume that the PH1 input the weaker source is then programmed to play at 20 counts higher Its volume offset will then read 20 The user can later select the PH1...

Страница 15: ...d STEREO Use the volume knob to set the condition to STEREO MONO or LAST Exit the programming mode by pressing and holding the Function button NOTE In the LAST mode the state of the Phase switch will...

Страница 16: ...ee below UNITY gain for the VK 32SE preamplifier correspond to the following volume setting CNTS display mode 100 Counts DBU 00 0dB DBM 20 0dB Exit the programming mode by pressing and holding the Fun...

Страница 17: ...source The examples may include CD 2 DVD1 JOHN VKD5 MARY BOB1 etc To program the input name do the following Select the desired input Press the Function button eight times The first character of the i...

Страница 18: ...button will cause the MUTE function in the VK 32SE to toggle between ON and OFF states The Mute LED on the VK 32SE front panel will reflect the status of the Mute circuit Fade Pressing the FADE button...

Страница 19: ...own fuse in the VK 32SE is an indication of a serious problem If a replacement fuse fails as well no further attempts should be undertaken Please contact the factory for professional service The prope...

Страница 20: ...l erase ALL user programmed setpoints and will return the unit to its factory default state In order to RESET the VK 32SE do the following 1 Turn the unit OFF 2 Disconnect the power cord from the back...

Страница 21: ...Resolution 5dB Volume Control Number of Steps 140 Frequency Response 2 Hz to 200 kHz Input Impedance minimum 100kOhm each phase Output Impedance 300 Ohm each phase Noise unweighted 96 dB Distortion a...

Страница 22: ...h by anyone other than Balanced Audio Technology or its specifically authorized agents 5 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the...

Отзывы: