background image

       XXE-4, 6, 8, 10, 12

     Gas Char Broiler

Figure C

        Burner / Accessories   

Page 4 of 4

      

Note: When ordering, ALWAYS specify Part #, Model #, Serial #,  Voltage/Phase & type of Gas.

       1/06

Item

 Part #

  Description

Item

 Part #

Description

30 Pine Street • New Rochelle • New York • 10801

914 / 576 - 0200
914 / 576 - 0605

1 - 800 - 431 - 2745

www.bakerspride.com

fax
US & Canada
web address

BAKERS

PRIDE

       Conversion Kit (LP to Nat)

       Conversion Kit (Nat to LP)

14
15
16
17
18
19
20

21
22
23
24
25
26
27
28

N1010A
R3147P
R3172P
R3023A

T1155T 

T1007A

G1470K

M1009A
M1184A

T5017A
T5018U
T5041T
T5016A
T5019V
T5104V

Ferrule, 3/16"
Orifice Hood #41, Nat (XXE)
Orifice Hood #53, LP (XXE)
Orifice Hood, Blank
Radiant, S/S (23")

 Standard

Radiant, Cast Iron (23")

 Optional

Heat Shield

 (XXE-4 uses 5) (XXE-6 uses 7)

(XXE-8 uses 9) (XXE-10 uses 11) (XXE-12 uses 13)

Pressure Regulator, 3/4", 10" WC
Pressure Regulator, 3/4", 3.5" WC
Wire Brush, Chef-Aide, 18"
Spatula, Chef-Aide, 20", Single
Grate Lifter, 3' x 20"
Meat Fork
Steak Turner
Twin Head Grate Brush

1

2
3
4
5
6
7
8
9

10
11
12
13

R1085P
R1086P
R1087P
R1088P
R1186A
N3068P
N5217P
R3128A

M1053A

R3181P
S1301A

L5078A

M1359A
G1472K
M1358A
M1267X

N1007A

Manifold Assy (XXE-4)
Manifold Assy (XXE-6)
Manifold Assy (XXE-8)
Manifold Assy (XXE-10)
Manifold Assy (XXE-12)
Pressure Tap Nozzle Assy
Inlet Gas Pipe (XX)
Valve, Multi Gas Cock
Valve, Junker (Old Style)
Pilot Tubing, 5" (XXE)
Knob, CE Broiler
Burner, Center Feed (XXE)
Pilot Burner
Pilot Burner Mounting Bracket

 (XXE)

Thermocouple, 10"
Thermocouple

 (used w/O.S. Junker Valve)

Compression Nut, 3/16", Female

R3147P

Hood Orifice # 41, Nat.

 

(XXE-4 uses 4) (XXE-6 uses 6) 

(XXE-8 uses 8) (XXE-10 uses 10) (XXE-12 uses 12)

M1184A

Pressure Regulator,

 3/4", 3.5" WC (Qty. 1)

R3172P

M1009A

Hood Orifice #53, L.P.

 

(XXE-4 uses 4) (XXE-6 uses 6) 

(XXE-8 uses 8) (XXE-10 uses 10) (XXE-12 uses 12)

Pressure Regulator, 

3/4", 10" WC (Qty. 1)

8

7

6

5

10

9

1

3

2

4

27

23

24

26

28

25

20

18

19

21

22

11

12

15 16 17

13

14

11

Содержание Dante XXE-10

Страница 1: ...pply has been connected to your unit it is extremely important to check piping for possible leaks To do this use soap and water solution or solutions which are expressly made for this purpose DO NOT USE matches candles flames or other sources of ignition since these methods are extremely dangerous Post in a prominent location instructions to be followed in the event you smell gas Obtain these inst...

Страница 2: ...d Valve Assembly Views 7 Parts List w Exploded Views 8 V WARRANTY ITEM PAGE Bakers Pride Limited Warranty 12 I INSTALLATION INSTRUCTIONS 1 INSTALLATION A INSTALLATION of this broiler must conform with the latest edition of National Fuel Gas Code and or local codes the American National Standard 2 223 1 in USA and CAN CGA B149 1 or 2 Installation Code in Canada In Europe this appliance must be inst...

Страница 3: ...upply line before connecting it to the unit For units using propane gas supply In USA and Canada lines less than 1 2 12 7 mm Inside diameter should not be used On the XXE series the gas connection is located on the right rear of the unit BE SURE TO CAPWHICHEVER SIDE IS NOT CONNECTED When making gas pipe connections pipe joint compound resistant to the action of liquefied petroleum gases should be ...

Страница 4: ... the pilot burner flame G Each burner may now be adjusted to the desired flame size by turning the individual burner valve knob H Turn the knob to the pilot burner ignition position to shut down the main burner I Turn the knob to off position to shut down the pilot burners NOTE WAIT FIVE MINUTES BEFORE ATTEMPTING TO RELIGHT THE PILOT BURNERS 8 GREASE PAN A grease pan is provided below the burners ...

Страница 5: ... allow the meat to sit covered on a heated platter for 2 5 minutes before cutting This will allow the juices to settle and the product will be more moist C Do not use forks or other sharp objects to poke holes in the meat Do not cut the meat as it cooks D Thick pieces of meat require a longer broiling time with less flare up Reduce flare up by trimming excess fat for a longer broil time without bu...

Страница 6: ...usted incorrectly Draft condition Improper ventilation system Debris or grease clogging pilot burner or thermocouple Pilot safety valve or thermocouple has failed Overload of fatty meat Orifices may be dirty clogged Low gas pressure Top grates may be dirty clogged If the ventilation is too strong it will suck heat from the cooking broiling surface Too many Glo stones restricting heat to top grates...

Страница 7: ...LY VIEWS Air Mixer Cap Manifold Air Mixer Cap Hold down Screw Valve Handle Burner Valve Pilot Burner Flame Sensor Air Mixer Cap Burner Orifice Holder Orifice Manifold FIGURE 1 XXE SERIES FRONT VIEW FIGURE 2 XXE SERIES SIDE VIEW ...

Страница 8: ... 4 Gas Char Broiler PARTS LIST Model Number 30 Pine Street New Rochelle New York 10801 914 576 0200 914 576 0605 1 800 431 2745 www bakerspride com fax US Canada web address BAKERS PRIDE XXE 4 6 8 10 12 Dante SERIES XXE 4 XXE 6 XXE 8 XXE 10 XXE 12 Serial Number Natural L P Other Type of Gas 8 ...

Страница 9: ...4 576 0605 1 800 431 2745 www bakerspride com fax US Canada web address BAKERS PRIDE Figure A Exterior Grates Page 2 of 4 Note When ordering ALWAYS specify Part Model Serial Voltage Phase type of Gas 1 06 XXE 4 6 8 10 12 20 19 18 17 16 15 14 13 12 11 21 1 3 8 9 7 2 4 10 6 5 9 ...

Страница 10: ...an XX 6 or 10 30 7 8 1 used Grease Pan XX 8 19 5 8 2 used Grease Pan XX 10 19 1 4 1 used Grease Pan XX 12 19 1 4 3 used Name Plate 13 1 4 Bakers Pride Leg 4 Adjustable Each Leg 4 Adjustable Set 4 Griddle Plate Optional 16 Grate Top Flat Cast Iron 5 1 4 Grate Fajita Bottom Grate Fajita Top Grate Meat 10 1 2 Grate Fish 10 1 2 G1011K G1012K G1458K G1459K G1454K G1455K G1456K G1457K G1412K G1474K G147...

Страница 11: ...3 4 3 5 WC Wire Brush Chef Aide 18 Spatula Chef Aide 20 Single Grate Lifter 3 x 20 Meat Fork Steak Turner Twin Head Grate Brush 1 2 3 4 5 6 7 8 9 10 11 12 13 R1085P R1086P R1087P R1088P R1186A N3068P N5217P R3128A M1053A R3181P S1301A L5078A M1359A G1472K M1358A M1267X N1007A Manifold Assy XXE 4 Manifold Assy XXE 6 Manifold Assy XXE 8 Manifold Assy XXE 10 Manifold Assy XXE 12 Pressure Tap Nozzle A...

Страница 12: ...eriod of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel milage or any other charges EXCLUSIONS Negligence or acts of God Thermostat calibrations after 30 days from equipment installation date Air and Gas adjustments Light bulbs Glass doors...