Bakers Pride Cyclone BCO-G1 Скачать руководство пользователя страница 3

3

For a single unit: Refer to Figure 4

(1) Tilt Oven over to left-hand side and attach two 31” legs on the right-hand side with three ½” bolts and 

washers. Tighten firmly.

(2) Using proper lifting equipment, lift up the left-hand side and attach two 31” legs on the left-hand side 

the same way.

For a stack of two ovens: Refer to Figure 3

(1)

 

Remove flue from bottom oven prior to stacking. When top oven is properly positioned on bottom 

oven, re-install the flue back on the bottom oven.

(2) Tilt lower unit over to the left-hand side and position two 6” legs on the right side (one for front and 

one for back), secure in place by using 4 bolts (3/8”-16) per leg. Tighten firmly.

(3) Using proper lifting equipment, lift up the left side of the unit and attach the other two legs in the same 

way.

(4) Using the lifting equipment, raise the top oven to proper height and slide on top of the bottom oven. 

Line up sides and front and fasten to each other at the rear of the units by using a mounting bracket 
supplied in the stacking kit.

To assemble an open rack stand: Refer to Figure 1

(1) Loosen 12 bolts (attaching 31” legs) slightly.
(2) Remove 4 inner bolts, 1 from each of the 4 legs, place top right angle and top left angle underneath 

and tighten these 4 bolts.

(3) Insert “Open Rack Shelf” and tighten into place with eight 3/8-16 screws, washers and nuts.
(4) Position “Rack Supports” and tighten in place using 4 each of flat washers and 5/16-18 Hex Nuts.

Fit  the  Standard  Flue  Diverter  supplied  into  the  hole  in  the  top  of  the  oven  for  under  ventilation  hood 
installation and secure with screws. For direct venting, Flue Adapter and Draft Hood must be placed into the 
hole on top of the oven.

C.  INSTALLATION WITH CASTERS (OPTIONAL): Refer to Figure 4

Four casters (two with wheel brakes) and the mounting hardware are packed and included in the shipment if 
ordered. Install casters with wheel brakes on the front of the unit. Installation of the unit should be made with 
a  connector  that  complies  with  the  latest  edition  of  the  Standard  for  Connectors  for  Movable  Gas 
Appliances ANSI  Z21.69  in  the  USA  (CAN  CSA-6.16  in  Canada)  and    a  quick-disconnect  device  that 
complies with the latest edition of the   standard for quick disconnect devices for use with gas fuel ANSI 
Z21.41 in the USA (CSA 6.9 in Canada). Adequate means must be provided to limit the movement of the 
appliance without depending on the connector and any quick disconnect device or its associated piping to 
limit appliance movement.

The restraint should be attached to the rear legs of the oven on which casters are mounted. If disconnect of 
the restraint is necessary, the restraint should be immediately reconnected after the appliance has been 
returned to its originally installed position.

Figure 1

OPEN RACK STAND ASSEMBLY INSTRUCTIONS: BCO-G & GDCO-G

Assembly Instruction

1. Place undershelf (6) between legs & secure 

with 1/4-20 UNC screws (4), flat washers (3) & 
locknuts (2). The holes for mounting the wire 
racks should be toward the front of the oven.

2. Place open rack supports (1) between legs & 

secure  with  1/4-20  UNC  screws  (4),  flat 
washers (3) & locknuts (2).

3. Slide wire rack supports (5) into position using 

the holes in the undershelf (6) as a guide.

1

2
3

4

5

6

Open Style Support Leg Not Supplied With Kit

1

21818222 Support, Open Rack        2

2

  770504

Lock Nut 1/4-20              12

3

 8519600 Washer, Flat 1/4”

12

4

 8208200 Screw, 1/4-20 x 3/4”        12

5

21816807 Support, Wire Rack

 2

6

21818231 Undershelf, Gas Oven

 1

Item       P/N        Description                 Quan

Содержание Cyclone BCO-G1

Страница 1: ...urces of ignition since these methods are extremely dangerous Instructions to be followed in the event you smell gas should be posted in a prominent location Obtain these instructions from your local...

Страница 2: ...tallation and Use Regulations and the relevant Building Regulations IEE Regulations Detailed recommendations are contained in the British Standard Codes of Practice B S 6172 B S 5440 Part 2 and B S 68...

Страница 3: ...ust be placed into the hole on top of the oven C INSTALLATION WITH CASTERS OPTIONAL Refer to Figure 4 Four casters two with wheel brakes and the mounting hardware are packed and included in the shipme...

Страница 4: ...er For Natural gas use 19 mm pipe The gas pressure regulator is part of the combination valve and is adjusted to yield a pressure of 3 5 water column 9 mbar for Natural Gas If the oven is ordered for...

Страница 5: ...esign and the installation of the hood conform to local municipal codes In the U K follow ventilation requirements as detailed in B S 5440 Optional direct venting not available for European community...

Страница 6: ...tronic Temperature Control and Electronic Hot Surface Direct Ignition System 2 Due to increased efficiency of this oven the temperature of standard recipes may be reduced 50 F 30 C 3 Always load each...

Страница 7: ...down Rotary control To cool down the oven to a lower desired temperature follow the steps detailed below 1 Open the oven doors 2 Turn Selector Switch to oven cool down position Fan will now operate an...

Страница 8: ...rub cleanser on the metal in the direction of the polished lines on the metal Rubbing cleanser as gently as possible in the direction of the polished lines will not mar the finish of the stainless st...

Страница 9: ...Oven Leg 2 8633515 Foot Insert Adjustable 3 8227700 Hex Hd 5 16 18 X 3 4 Bolt 5 Zn 4 8509300 Washer Flat SAE 5 16 5 8435000 Hex Nut 5 16 18 6 82447 00 Hex Hd 3 8 16 X 750 5 1 Attach four item 2 to fou...

Страница 10: ...21 16 19 20 17 18 35 29 11 20 26 34 10 1 7 3 9 BUTT SPLICE L1 24VAC GROUND FLAME SENSE VALVE HOT THERMOSTAT IGNITOR 22 40 41 BUTT SPLICE GROUNDSTUD 3 2 1 4 26 IGNITION CONTROL 7 6 4 3 2 1 GROUND STUD...

Страница 11: ...35 29 11 20 26 34 10 1 7 3 9 BUTT SPLICE L1 24VAC GROUND FLAME SENSE VALVE HOT THERMOSTAT IGNITOR 22 40 41 GROUND STUD 3 2 1 4 26 IGNITION CONTROL 7 6 4 3 2 1 Plug or Connection Supplied at installat...

Страница 12: ...High Speed Set fan to Low Speed Flame Sensor defective Meats are well done and not browned Bake longer or raise oven temperature slightly Do not open doors to oven for long periods Oven cycles 3 times...

Страница 13: ...10801 914 576 0200 914 576 0605 1 800 431 2745 www bakerspride com fax US Canada web address BAKERS PRIDE Cyclone SERIES 4 05 Note When ordering ALWAYS specify Part Model Serial Voltage Phase type of...

Страница 14: ...5A KIT CONVERSION TO LP E8766A KIT CONVERSION TO NAT Part Description 1 33 0 34 5 4 12 2 3 30 8 10 11 28 29 9 32 31 27 17 26 20 19 24 7 22 18 13 25 21 14 15 16 23 39 44 45 37 47 74 73 67 50 49 40 46 4...

Страница 15: ...R3165A VALVE COMBINATION NAT VALVE COMBINATION L P 1 1 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 N5019A E81...

Страница 16: ...eriod of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not incl...

Отзывы: