Bakers Pride BPH-HPS-848i Скачать руководство пользователя страница 14

HEAVY DUTY HOT PLATE OPERATION MANUAL

TABLE OF CONTENTS

12

Be sure to keep up with new product announcements 

and events on social media!

The Standex Food Service Equipment Group (FSEG) is a manufacturer of innovative commercial food 

service equipment offering a wealth of refrigeration and cooking expertise. Products include walk-in 

coolers and freezers; hot and cold display cabinets, cases, and storage systems; commercial ovens, 

rotisseries, and cooking equipment; and rotary vane pumps.

Ask your sales representative about how the power of all Standex brands can work for you.

www.standex.com/segments/food-service

Food Service Equipment Group

Содержание BPH-HPS-848i

Страница 1: ...BUILT BY CRAFTSMEN TESTED BY TIME SERIES BPHHP BPHHPS OPERATION MANUAL HD COOKLINE SERIES COUNTERTOP HOT PLATES ...

Страница 2: ...ll safety precautions must be taken in the event the user smells gas Safety information can be obtained from your local gas supplier WARNING BAKERS PRIDE OVEN COMPANY LLC 1307 N Watters Rd Suite 180 Allen TX 75013 Phone 800 527 2100 Fax 914 576 0605 www bakerspride com P N 8835515 9 18 Bakers Pride Oven Company LLC is a wholly owned subsidiary of Standex International Corporation All gas operated ...

Страница 3: ...supply the necessary forms B Concealed damage or loss if not apparent until after equipment is uncrated a request for inspection must be made to the carrier within 15 days The carrier should arrange an inspection Be certain to hold all contents and packaging material Installation and start up should be performed by a qualified installer who thoroughly read understands and follows these instruction...

Страница 4: ... vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA96 latest edition that local codes are Authority Having Jurisdiction when it comes to requirement for installation of equipment Therefore installation should comply with all local codes NOTICE Improper installation operation service or maintenance can cause property damage injury or death Read and...

Страница 5: ...lve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 45 kPa Congratulations on your purchase of Bakers Pride commercial cooking equipment Bakers Pride takes honor in designing the highest quality products When used as intended and with proper care and maintenance you will experience years of reliable operation from this equipment To ensu...

Страница 6: ... 23 1 2 4 BPHHPS 848i 48 31 14 FR 17 RR 44 3 4 23 1 2 4 Dimensions BPHHP 212i Shown for clarity MODEL of BURNERS BTU hr PER BURNER NAT GAS BTU hr TOTAL NAT GAS BTU hr PER BURNER PROPANE BTU hr TOTAL PROPANE in W C NAT GAS in W C PROPANE BPHHP 212i 2 30 000 60 000 25 000 50 000 5 10 BPHHP 424i 4 30 000 120 000 25 000 100 000 5 10 BPHHP 636i 6 30 000 180 000 25 000 150 000 5 10 BPHHP 848i 8 30 000 2...

Страница 7: ... reset burner ignition The pilot flame should be as small as possible but large enough to guarantee reliable ignition of the burners when the knobs are turned to HI Relighting the Pilot If the pilot light should go out for any reason Promptly shut off all gas at the manual shut off valve Turn off all knobs and pilot valves wait 5 minutes to clear gas Relight following steps 4 through 6 under Stand...

Страница 8: ...the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricated periodically This must be done by an authorized service representative in your area MAINTENANCE Use only non abrasive cleaners Abrasive cleaners could scratch the finish of your unit marring its appearance and making i...

Страница 9: ...Change the orifices to the size recommended for propane L P 3 Replace the orifice fittings into the valve To change the regulator CONVERSION Connect the regulator to the unit connect gas and check for leaks Check the system pressure With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold...

Страница 10: ...been adjusted replace the brass cap Note the blue cap on the regulator This is the vent There are openings below the top rim NEVER block these openings your regulator will fail to operate correctly On at least a monthly basis blow off any dust or grease which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere NOTI...

Страница 11: ...310389 MANIFOLD 424 1 311037 MANIFOLD 636 1 310310 MANIFOLD 848 1 12 310266 BURNER HANGER 1 2 3 4 13 22461033 PANEL CONTROL BPHHP 2i 1 22461053 PANEL CONTROL BPHHP 4i 1 22461073 PANEL CONTROL BPHHP 6i 1 22461093 PANEL CONTROL BPHHP 8i 1 ITEM PART DESCRIPTION QTY 212 424 636 848 14 2068000 VALVE GAS ON OFF 2 4 6 8 15 2065643 VALVE 90 PILOT 1 8 NPT X 3 16 1 2 3 4 16 311016 GRATE TOP 12 X 12 RANGE 2 ...

Страница 12: ...tes Radiants Stones and Valves are covered for a period of SIX MONTHS All Ceramic Baking Decks are covered for a period of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel mileage or any other charges EXCLUSIONS Negligence or acts of God Fai...

Страница 13: ...11 NOTES ...

Страница 14: ...mercial food service equipment offering a wealth of refrigeration and cooking expertise Products include walk in coolers and freezers hot and cold display cabinets cases and storage systems commercial ovens rotisseries and cooking equipment and rotary vane pumps Ask your sales representative about how the power of all Standex brands can work for you www standex com segments food service Food Servi...