BP SERIES RANGES OPERATION MANUAL
4
The arrow shown on the bottom of the regulator body
shows the gas flow direction, it should point downstream
to the appliance. The red air vent cap on the top is part
of the regulator and should not be removed.
Any adjustments to the regulator should be made
by qualified service personnel only with the proper
equipment.
Connections
Please check installer supplied intake pipes visually
and / or blow them with compressed air to clear any dirt
particles, threading chips or any other foreign matter
before installing a service line. When gas pressure is
applied, these particles could clog orifices.
All connections must be sealed with a joint compound
suitable for LP gas, and all connections must be tested
with a soapy water solution before lighting any pilots.
Flexible Couplings, Connector and Casters
For an appliance equipped with casters, the installation
shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances,
ANSI Z21.69 or Connectors for Moveable Gas
Appliances, CAN/CGA-6.16, and a quick disconnect
device that complies with the Standard for Quick
Disconnect Devices for Use With Gas Fuel, ANSI
Z21.41, or Quick Disconnect Devices for Use With Gas
Fuel, CANI-6.9.
If disconnection of the restraint is necessary, make
sure to reconnect restraint after the appliance has been
returned to its originally installed position. Domestic gas
or water connectors are not suitable.
Restraining device may be attached to the back frame /
panel of the unit.
If the appliance is to be installed with casters, a flexible
connector must be used and the same ANSI standards
apply. Locking front casters are provided to limit the
movement of the appliance without depending on the
connector or associated piping. A suitable strain relief
must be installed with a flexible connector.
All connections must be sealed with a joint compound
suitable for LP gas and all connections must be tested
with soap water solution before lighting pilots.
MAINTENANCE INSTRUCTIONS
Initial Pilot Lighting
When lighting pilots and checking for leaks, do
not stand with your face close to the combustion
chamber.
CAUTION
All appliances are adjusted and tested before leaving
the factory, effectively matching them to sea level
conditions. Adjustments and calibrations to assure
proper operation may be necessary on installation to
meet local conditions, low gas characteristics; correct
possible problems caused by rough handling or
vibration during shipment and are to be performed only
by qualified service personnel.
These adjustments are the responsibility of the customer
and/or dealer and are not covered by our warranty.
Check all gas connections for leaks with a soapy water
solution before lighting any pilots.
Do not use any flame to check for leaks.
CAUTION
Before lighting any pilots, make sure that burner valves
and thermostats are turned “OFF”.
Top Burners / Raised Griddle / Broiler
All top section burners are equipped with constant
burning pilots. These are to be manually lighted
immediately after the gas is turned on and the system is
checked for leaks. Burner pilots are provided for each
burner and can be rechecked for proper adjustment.
All adjustments can be made with a screw driver to the
brass pilot valve accessible through the valve cover.
Griddle
The pilot should be lighted immediately after the gas
is turned on and the system is checked for leaks. The
pilot can be reached with a long match through the
valve cover, or by lifting the plate upward and accessing
through the top. Adjustment of the pilot flame can be
made with a screwdriver to the pilot valve, accessible
through the valve cover.