background image

 

4

  

SAFETY INSTRUCTIONS 

Please read this manual carefully and familiarize yourself with all aspects of the Cell-Culture Chamber 
System.  
The System comprises a Gas Controller and a Cell-Culture Chamber.  
Baker and/or Ruskinn does not accept responsibility for accidents to personnel or damage to the Cell-
Culture Chamber System resulting from incorrect use.  
The mains appliance coupler and plug are the AC mains supply isolation device and must be easily 
accessible when installed.  
In case of emergency disconnect the Gas Controller from the AC Mains Outlet.  
Ensure that the connecting cable is not squeezed or bent when the System is being installed or moved. 
All installation work and adjustments to the System must be carried out by qualified personnel.  
Work  performed  by  persons  with  insufficient  technical  knowledge  may  adversely  affect  the 
performance of the system or cause physical injury or damage to the equipment.  
All servicing and repairs must be carried out by a qualified customer service engineer.  
Only genuine spare parts must be used.  
All gas cylinders must be adequately secured before connection to the System. 
 

CAUTION: Asphyxiation Risk 

The PhO

2

xBox uses Nitrogen (N

2

) and Carbon Dioxide (CO

2

) as part of normal use with the volume 

released  externally  is  inconsequential.  In  the  event  of  a  leak  or  malfunction  this  gas  release  may 
become excessive. DO NOT OPERATE this unit in a SMALL ENCLOSURE such as a small room or walk-
in  closet.  An  accidental  release  of  Nitrogen  or  Carbon  Dioxide  could  create  an  asphyxiating 
atmosphere in a small space. 

If the equipment is not use in a manor specified by the manufacture, the protection provided by the 
equipment may be impaired. 

Failure  to  adhere  to  these  safety  instructions  could  cause  serious  injury  and  will  invalidate  the 
workstation warranty. Ruskinn technology limited accepts no responsibility for any accident, injury or 
loss caused by unsafe operation of the workstation. 

 

Содержание Ruskinn PhO2xBox

Страница 1: ...Affix Serial Number Sticker Here User Manual UM 048 PhO2xBox Cell Culture Chamber System PhO2xBox...

Страница 2: ...MBER 13 SETTING UP THE CELL CULTURE CHAMBER ON A LABORATORY BENCH 13 FOR INSTALLATION INSIDE A WORKSTATION SCI TIVE OR INVIVO2 OR CO2 INCUBATOR 14 USING THE GAS CONTROLLER 17 THE TOUCH SCREENS 19 STAR...

Страница 3: ...igure 18 Front View 17 Figure 19 Left View 17 Figure 20 Right View 17 Figure 21 Rear View 17 Figure 22 Rear View Multi version 18 Figure 23 Top View 18 Figure 24 Screen 1 Logo screen 19 Figure 25 Scre...

Страница 4: ...has built in gas control with Oxygen and Carbon Dioxide sensors to enable constant monitoring of the atmosphere Hypoxic conditions are created using Nitrogen N2 Carbon Dioxide CO2 and Compressed Air O...

Страница 5: ...em or cause physical injury or damage to the equipment All servicing and repairs must be carried out by a qualified customer service engineer Only genuine spare parts must be used All gas cylinders mu...

Страница 6: ...must not be treated as household waste Instead it shall be handed over to an appropriate collection point for the recycling of electrical and electronic equipment If in doubt please return this equip...

Страница 7: ...Hazard and actions to be taken in order to avoid the Hazard Warning this equipment contains high voltage circuitry Contains material or substances that may be hazardous to human health Please refer to...

Страница 8: ...lled or relocated by a qualified engineer To arrange installation or relocation please contact your local distributor The mains appliance coupler and plug are the AC mains supply isolation device and...

Страница 9: ...Electrical Service Requirements Gas Supply Requirements The gas regulator should provide a minimum supply pressure of 2 bar gauge The maximum supply pressure permissible is 3 bar gauge See Table 4 be...

Страница 10: ...hich is sucked into the Gas Controller via an Air pump The user can select the Oxygen concentration from 0 3 to 20 0 and the Carbon Dioxide concentration from 0 3 to 20 0 The Cell Culture Chamber is w...

Страница 11: ...10 Figure 1 Blue Tube Figure 2 Mains Lead Figure 3 Signal Lead Figure 4 Gas Controller With air pump...

Страница 12: ...11 Figure 5 N2 Gas Hose Figure 6 CO2 Gas Hose Figure 7 Cell Culture Chamber Small QTK A01 Figure 8 Cell Culture Chamber Large QTK A02...

Страница 13: ...12 Figure 9 Cell Culture Chamber Large QTK AB02...

Страница 14: ...Chamber can be placed adjacent to or on top of the Gas Controller Connect the blue tube to InA on the Cell Culture Chamber and OutA on the Gas Controller Connect the signal lead to InB on the Cell Cul...

Страница 15: ...wn on Gas Controller Open gas cylinders and turn the gas controller power on For installation inside a workstation SCI tive or InvivO2 or CO2 Incubator Place Cell Culture Chamber in desired Workstatio...

Страница 16: ...Additional holes can also be drilled by user Connect the blue tube to InA on the Cell Culture Chamber and OutA on the Gas Controller The blue tube has to be put through the Universal Multi Cable glan...

Страница 17: ...he Gas Controller to the N2 gas cylinder and the black hose to connect CO2 on the Gas Controller to the CO2 cylinder Connect the mains lead to the right port shown on Gas Controller Figure 17 Pneumati...

Страница 18: ...17 USING THE GAS CONTROLLER Gas Controller The Gas Controller is shown as follows Figure 18 Front View Figure 19 Left View Figure 20 Right View Figure 21 Rear View...

Страница 19: ...18 Figure 22 Rear View Multi version Figure 23 Top View...

Страница 20: ...en Screen 1 will appear and then will be replaced by the Main Screen Screen 2 Figure 24 Screen 1 Logo screen Main screens From this menu you will be able to access the Main screen below Figure 25 Scre...

Страница 21: ...menu is then displayed with the currently active chamber displayed in the top left corner Figure 27 Multi chamber version main screen Atmosphere Control Screen Pressing the Atmosphere Control bar on...

Страница 22: ...pear for the new setting to be selected as shown in Screen 4 Press Enter once the desired value of O2 is selected Figure 29 Screen 4 Level SET POINT Screen Repeat for CO2 Once O and CO set points have...

Страница 23: ...he timing values define how long the Oxygen and Carbon Dioxide levels are maintained for once they have been achieved This means that there is a time period between the steps that cannot be set as it...

Страница 24: ...pear from the system USB Save Press USB Save button and the data log will downloaded to a USB Figure 32 Screen 7 Trend Log Engineer Mode Screen To set the control parameters enter the Engineer Mode sc...

Страница 25: ...ng time when the unit enters the intermittent adjustment mode Switch off range 1 20s means rest time when the unit enters the intermittent adjustment mode for example if set switch on at 2s and switch...

Страница 26: ...he chamber can withstand up to 60 The Cell Culture Chamber is connected to Gas Controller which contains O and CO sensors A dish of distilled water can be installed in the culture chamber to increase...

Страница 27: ...ICULAR PURPOSE THE IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE CUSTOM OR USAGE OF TRADE Ruskinn Technology Limited DOES NOT WARRANT...

Страница 28: ...old waste site Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Alternatively please contact your local distributor for disposal...

Страница 29: ...Sales sales bakerruskinn com Technical support techsupport bakerruskinn com General enquiries ruskinnoffice bakerruskinn com Website www bakerruskinn com YouTube channel http www youtube com ruskinnte...