background image

ES-787 Rev E

Page 3 of 6

{Intrinsically Safe}
IS CL I, II, III; DIV 1; GP A, B, C, D, E, F, G

{Non-Incendive, gas}
NI CL I; DIV 2; GP A, B, C, D

{Suitable for dust & fibers,Div 2}
SUITABLE FOR CL II, III; DIV 2; GP F, G

{Explosionproof, gas}
XP CL I; DIV 1 GP B, C, D

{Suitable for dust, Div 1}
SUITABLE FOR CL II; DIV 1; GP E, F, G

{Suitable for fibers,Div 1}
SUITABLE FOR CL III, DIV 1

T5 Ta=85°C T6 Ta=75°C

(ATEX)

AT EX S P ECIFIC N O T E:

PERMANENTLY MARK THE PROTECTION TYPE CHOSEN. ONCE THE TYPE HAS BEEN MARKED, IT CAN NOT BE CHANGED

Certificate Number -

FM11ATEX0008X

{Intrinsically Safe, gas}
II 1G Ex ia IIC T6…T5 Ga

{Intrinsically Safe, dust}
II 1D Ex ia IIIC T96°C Da

Certificate Number -

FM06ATEX0004X

{FlameProof, gas}
II 2G Ex db IIB+H2 T6…T5 Gb

{FlameProof, dust}
II 2D Ex tb IIIC T96°C Db

Certificate Number -

FM06ATEX0005X

{Limited Energy, gas}
II 3G Ex ic IIC T6…T5 Gc

{Limited Energy, dust}
II 3D Ex tc IIIC T96°C Dc

O peratingR anges

5.5.1

Ambient Temperature: -50°C to +85°C

5.5.2

Electrical:

30 VDC Max,

1 Watt Max

Ui=6.5 Volts

li=10.5mA

Ci=0.066µF

Li=0

Pi=68mW

AP P R O VED

(See Product Label For NB Number)