Safety Information

Important - Please read before installation

These instructions contain 

DANGER

WARNING

and 

CAUTION 

labels, where necessary, to alert 

you to safety related or other important information. 

Read the instructions carefully 

before 

installing 

and maintaining your control valve. 

DANGER 

and 

WARNING 

hazards  are related  to personal injury. 

CAUTION 

hazards involve equipment or property 

damage. Operation of damaged equipment can, 

under certain operational conditions, result in 

degraded process system performance that can 

lead to injury or death. Total compliance with all 

DANGER

WARNING

, and 

CAUTION 

notices is 

required for safe operation.

This is the safety alert symbol. It alerts you to potential 

personal injury hazards. Obey all safety messages 

that follow this symbol to avoid possible injury or 

death.

Indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not 

avoided, could result in serious injury.

Indicates a potentially hazardous situation which, if not 

avoided, could result in minor or moderate injury.

When used without the safety alert symbol, indicates 

a potentially hazardous situation which, if not avoided, 

could result in property damage.

Note: Indicates important facts and conditions.

About this Manual

• 

The information in this manual is subject to change 

without prior notice.

• 

The information contained in this manual, in whole 

or part, shall not be transcribed or copied without 

Baker Hughes’s written permission.

• 

Please report any errors or questions about the 

information in this manual to your local supplier.

• 

 These instructions are written specifically for the 

Model 78-80S and Model 08-80S transfer valve, 

and do not apply for other valves outside of this 

product line.

Warranty

Items sold by Baker Hughes are warranted to be 

free from defects in materials and workmanship for a 

period of one year from the date of shipment provided 

said items are used according to Baker Hughes 

recommended usages. Baker Hughes reserves the 

right to discontinue manufacture of any product or 

change product materials, design 

or specifications 

without notice.

Note - prior to installation:

• 

The valve must be installed, put into service 

and maintained by qualified and competent 

professionals who have undergone suitable 

training.

• 

All surrounding pipelines must be thoroughly 

flushed to ensure all entrained debris has been 

removed from the system.

• 

Under certain operating conditions, the 

use of damaged equipment could cause a 

degradation of the performance of the system 

which may lead to personal injury or death.

• 

Changes to specifications, structure, and 

components used may not lead to the revision 

of this manual unless such changes affect the 

function and performance of the product.

• 

Содержание Masoneilan 08-80S

Страница 1: ...Masoneilan Model 78 80S 08 80S Transfer Valves Instruction Manual Rev B Baker Hughes Data Classification Public...

Страница 2: ...REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN...

Страница 3: ...iew___________________________________________ 5 2 Specifications_______________________________________ 5 3 Certifications________________________________________ 5 4 Mounting________________________...

Страница 4: ...e Indicates important facts and conditions About this Manual The information in this manual is subject to change without prior notice The information contained in this manual in whole or part shall no...

Страница 5: ...erating temperature range 30 C to 83 C option 0 C to 100 C 3 Certifications This instrument is certified in Azerbaijan AzSERTCENTER Russian Federation CU TR Ex Armenia Uzbekistan UZSTANDART Belarus Ch...

Страница 6: ...supply air pressure and set the air pressure to SIG at specified pressure by operating the pressure reducing valve while watching air pressure to SIG on the pressure gauge e Turn the adjust knob 14 c...

Страница 7: ...Masoneilan 78 80S 08 80S Transfer Valves Instruction Manual 7 2021 Baker Hughes Company All rights reserved Transfer Valve Model 78 80S Sectional Drawing...

Страница 8: ...Ring NBR 1 7 O Ring NBR 1 8 O Ring NBR 1 9 O Ring NBR 1 11 Bottom Cap ADC12 CROMATE 1 12 Filter SUS304 2 13 Spring Case ADC12 CHROMATE 1 14 Adjust Knob VALOX420 1 15 Diaphragm Plate SUS303 1 16 Exhaus...

Страница 9: ...Model 08 80S Sectional Drawing Part N Part Name Material Qty 1 Body ADC 12 ANODIZE 1 2 Head Cap ADC 12 CHROMATE 1 3 Plug SUS303 NBR 1 4 Piston ADC12 CHROMATE 1 5 Spring SUS304 WPB 1 6 O Ring NBR 1 7 O...

Страница 10: ...ghes com Copyright 2021 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representation...

Отзывы: