Before connecting the regulator, check the incoming line pressure as these regulators can only withstand a maximum inlet pressure
of 14" W.C. (1/2 PSI); exceeding this pressure will damage them. If the gas supply line pressure is greater than this amount, a step-down
regulator will be required.
A gas ow direction arrow is cast into the body of the regulator to minimize installation error it should point downstream to the
appliance. T he blue air vent cap on the top of the regulator is part of the regulator and should not be removed.
!
WARNING
Any adjustment to the regulator must be made only by qualified and licensed s e r v i c e personnel with the proper calibrated test
equipment. Gas connections should be performed by a qualified licensed contractor.
In the event of a power failure, no attempt should be made to operate the unit during power failure.
Before lighting, check all joints in the gas supply line for leaks. Do not use an open ame to check for leaks!
1. Turn pilot valves to OFF position by turning adjustment screws clockwise.
2. Turn ON the manual gas valve at the inlet side of the gas supply line.
3. Check for gas leaks at the exible coupling or gas connector tting using a solution of one par t soap and three par ts water.
4. Sparingly spray or brush the soapy solution at the gas ttings; active bubbling indicates location of gas leak.
6. Turn pilot adjustment screw counter-clockwise, then light standing pilot and adjust ame 1/4" high.
7. Turn ON gas valve/thermostat to light main burners.
8. For complete shut down, shut o gas valves and turn pilot adjustment
screw clockwise to shut o gas to the pilots.
5 . If a gas leak is detected turn o the manual gas valve at the inlet side of the gas line. Call your cer ti ed and licensed
service technician.
OPERATING INSTRUCTIONS
PILOT ADJUSTMENT SCREW
MORE GAS
LESS GAS
+
-
Use soap and water solution.