It takes time for the water to get heated. Therefore, switch ON the unit well in advance before use. The 

Heater unit can always be kept ON. Insulation keeps the water hot and thermostat makes sure that the 
electric supply is alternately switched ON and OFF. 

 

7. 

Every once in a while, check the working of the neon lamps to make sure that the thermostat and thermal 

cut-out are working properly. 

 

8. 

The red neon lamp glows ON when i) the thermostat fails OR ii) water temperature reaches 

boiling point OR iii) the heater unit is operating without water. This indicates that the thermal 
cut-out has operated thereby switching OFF the main power supply to the unit. In such a case 
contact the nearest Bajaj sales or service centre.
 

 

9. The power supply to the Heater can be kept ON continuously. But it is advisable to switch it OFF when the 

unit is not in use for a long time to save on electricity.  

 

 

Bajaj Storage Water Heater Performance Parameters as Per BIS

 

Model

 

Capacity 

(in litres)

 

Element Rating (in 

KW)

 

Min. Hot Water 

Output (at 

o

C)

 

Reheating Time 

(in minutes)

 

Mixing Factor 

(%)

 

Powder Coated Vertical Models

 

EE 6

 

6

 

3.0

 

50

o

 

9

 

30

 

EE 10

 

10

 

3.0

 

50

o

 

10

 

30

 

EE 15

 

15

 

2.0

 

50

o

 

20

 

30

 

EE 25 Dwarf

 

25

 

2.0

 

50

o

 

35

 

30

 

EE 25

 

25

 

2.0

 

50

o

 

35

 

30

 

EE 35

 

35

 

2.0

 

50

o

 

40

 

30

 

EE 15 

Designer

 

15

 

2.0

 

50

o

 

20

 

30

 

EE 25 

Designer

 

25

 

2.0

 

50

o

 

35

 

30

 

Powder Coated Horizontal models

 

EE 15

 

15

 

2.0

 

50

o

 

25

 

30

 

EE 25

 

25

 

2.0

 

50

o

 

40

 

30

 

EE 35

 

35

 

2.0

 

50

o

 

40

 

30

 

Stainless Steel Vertical Models

 

EE 15

 

15

 

2.0

 

50

o

 

20

 

30

 

EE 25 Dwarf

 

25

 

2.0

 

50

o

 

35

 

30

 

 

 

 

Содержание Storage Water Heater

Страница 1: ...Fusible plugs and c Thermal insulation to retain heat 2 Water comes into the inner tank through the inlet pipe at normal working pressure of about 30 P S I 3 When the tank is full this becomes clear...

Страница 2: ...the inner tank for optimum insulation i e to ensure minimum heat loss Standing heat loss is 30 lower than norms specified by The Bureau of Indian Standards BIS This insulation keeps the water hot for...

Страница 3: ...ls or fixture are strong enough to carry the weight of the heater when it is completely filled with water D A typical installation for vertical and horizontal mountings is shown in Fig 2 3 4 5 For ove...

Страница 4: ...70 228 15 EE 10 10 3 0 12 16 03 1 2 214 195 445 264 14 EE 15 15 2 0 20 29 00 1 2 214 235 475 303 14 EE 25 25 2 0 30 36 00 1 2 214 385 663 303 14 EE 25 Dwarf 25 2 0 30 36 50 1 2 214 260 540 355 14 EE 3...

Страница 5: ...pressure In such cases water in the heater flows back and out through the inlet pipe There is no air to fill the space created as a result of the water flowing back Hence there is a vacuum which puts...

Страница 6: ...e main power supply to the unit In such a case contact the nearest Bajaj sales or service centre 9 The power supply to the Heater can be kept ON continuously But it is advisable to switch it OFF when...

Страница 7: ...the vent nut and extend the vent pipe up to the top level of overhead water supply tank INSTALLATION CHART Fig 12 i Inlet water pressure is more than 30 P S I OR ii Height of water tank is more than...

Страница 8: ...not operate the unit by resetting the thermal cut out What you should do is contact the nearest Bajaj sales and service station to check if there is a fault 10 Always drain out the water when i the un...