INSTALLATION
2. INSTALLATION OF BATH
(Cont’d)
NOTES
• T
o install the Evanescence Freestanding
on a concrete slab with no place for the
passage of the air inlet pipe to the
bathtub: drill a hole 1 5/8 inches in
diameter in the skirt.
IMPORTANT:
drill
the hole 1 1/2 inches above floor level
and protect the bathtub with a piece
of wood placed behind the location
to be drilled.
2-3
Install the bathtub on the anchor points
fastened to the floor and immediately wipe
away any excess silicone. Connect the drain.
2-4
Install the turbine according to the
instructions in the TURBINE – DISTANCE
INSTALLATION section of the manual.
The air inlet is located to the right of the
bathtub drain and, if applicable, control
and option connection cables to the right.
Connect control and option cables
if applicable.
For Geysair-equipped
baths,
also run the water hose and
electrical wiring through the floor.
2-5
For Geysair-equipped baths,
connect
the Geysair electrical wire supplied with
the male connector with the turbine cable
equipped with the female connector.
Test
for grounding continuity between the
bath grounding terminal
and the
bath power supply.
Failure to perform
the grounding continuity test could
result in serious personal injury.
Ground Wire
for the Bathtub
Turbine Female
Connector
Geysair Male
Connector