INTRODUCTION
OPTIONS AND ACCESSORIES
1 - 10
WBPEEUI110505A0
OPTIONS AND ACCESSORIES
Table
lists and describes the options and accessories avail-
able with the Type PTSDL level transmitter.
FM and CSA
certifications
7,8
Explosionproof and
dust-ignitionproof
Class I, Division 1, Groups B, C and D; Class II, Division 1, Groups E, F and G;
Class III
Intrinsically safe
Classes I, II and III, Division 1; applicable groups when connected per drawing
B222611
Nonincendive
Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E, F and G;
Class III
NOTES:
1. The normal operating temperature range is that at which the transmitter meets all specifications. The extreme operating temperature
range is that at which the transmitter remains powered without damage.
2. All transmitters with fluorinated oil filled cells can only be operated in temperatures from -10° to +80°C (+14° to +176°F).
3. The transmitter can be operated with fluid temperatures up to 150°C (302°F).
4. The normal operating temperature range for the LCD is that at which the LCD remains functional. Exceeding those conditions may cause
the LCD to go blank. The transmitter remains functional to its operating limits. When the temperature returns to the acceptable range,
the display is restored; however, the life of the display may be reduced.
5. The minimum supply voltage necessary to support communications is 17 VDC.
6. Add 0.4 VDC to all minimum supply voltage values if using the lightning arrestor option.
for the ambient condition limits for certified applications.
8. The transmitters are only certified for those agencies and classes indicated on the certification label. Do not install the transmitters in
locations for which they are not suited. Refer to Table
1-2
, nomenclature position 12.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Table 1-4. Ambient Condition Limits for Certified Applications
Agency
Category
T
max
T
min
P
max
P
min
O
2max
°C
°F
°C
°F
kPa
psia
kPa
psia
%
FM
Explosionproof
80
176
-40
-40
108
15.7
86
12.5
21
Dust-ignitionproof
Intrinsic safety
65 (T4)
149 (T4)
Nonincendive
CSA Explosionproof
60
140
Dust-ignitionproof
Intrinsic safety
40 (T3C)
60 (T3A)
104 (T3C)
140 (T3A)
Nonincendive
60 (T4A)
140 (T4A)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Table 1-3. Specifications
(continued)
Property
Characteristic/Value
Table 1-5. Options and Accessories
Item
Description
Type STT Smart Transmit-
ter Terminal
Hand-held device for calibration, configuration, monitoring, and troubleshooting.
Also communicates with HART devices.