4-20
4
Caravan Equipment
▲
Gas Faults
Remedies:
Set the energy selector switch (A) to position “OFF”.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
4. Set the main switch (A) to “on”. The reignition starts again.
If after about 30 seconds the operating display (C) starts flashing red again, the gas fault has
not been cleared (e.g. air in the gas pipe).
5. Briefly switch the refrigerator off and then on again using main switch (A). To remove air from the gas
pipes, repeat this procedure 3-4 times.
If these actions do not help, please call an authorised Dometic Service Centre.
4.11.5 Temperature Setting Cooling Compartment
▲
The cooling unit’s performance is influenced by ambient temperatures.
▲
TIP: Please select the
medium setting
for ambient temperatures b15
°
C and
+25
°
C. The unit operates within its optimum performance range.
In the event of a gas fault (e.g. gas cylinder empty),
the operating display (C) flashes yellow.
As shown, you are able to regulate the
temperature of the cooling compartment, if
necessary, by turning rotary knob (B).