22
22
SLIDING TABLE INSTALLATION
The sliding table was installed and adjusted for parallelism at the factory. DO NOT change or
damage the the adjusting bolts (A) during installation of the sliding table.
Clean the rust preventative off of the contact surfaces (B) for the main cabinet and the sliding
table (Total 3 contact surfaces).
Remove the access covers (C) from behind the 2 outer mouning points. The center mount is
accessed through the clearance slot (D) for tilting the blade.
Note Use care when placing the sliding table on the contact surfaces so as not to
damage the surfaces. The sliding table may require from 4~ 6 workers to lift safely.
Using the assistants, lift the sliding table onto the machine taking care not to damage the
contact spots. Looking closely at the edge of the sliding table base, you should be able to
see the spots where the adjusting bolts have contacted the sliding table. Use these marks to
help align the bolt holes.
Install the 3 mounting bolts hand tight.
Verify that the sliding table base is tight against the adjusting bolts and slightly tighten the 3
mounting bolts.
A
A
B
C
D