Air circulation patterns will vary depending upon which air flow speed is used and your specific 
shop setup. 
In general, good air filter placement promotes a circular / recirculating air flow pattern. 
 
An example of poor air circulation, is where the air filter is placed too close to obstructions. This 
situation will cause the velocity and flow of the air to be lost and circulation and thus filtration will 
be diminished. Common placement and positioning issues are placing the inlet toward the 
center of a room with the outlet toward the wall or corner with less than 3 -4 feet (.9 

– 1.2m) of 

clearance. This will create a turbulence on the outlet side of the filter greatly reducing it 
efficiency. 
 
Placement and Position considerations: 

  Examine the shop layout and try to determine the best location to hang the air filter. Air flow 

that is obstructed will cause poor air flow, producing unsatisfactory results. There must be a 
clearance of at least 3ft (.9m) from any obstructions in front and back of the unit. 

  Try to place the air filter in near high dust producers or near areas where the dust is created. 

  Do not place the hanging air filter where overhead items such as doors, cranes, etc. may 

impede the air flow, or where the air filter may impede the other device operation of 
movement. 

  Consider the air flow of other air controlling devices such as HVAC and ceiling fans. Try to 

have the air filter work with the air flow of these devices. 

  Plan for placement to allow the air filter to be operated, serviced, cleaned, and maintained. 

  Plan for and consider the proximity to the power source. Consider the air flow of other air 

controlling devices such as HVAC and ceiling fans. Try to have the air filter work with the air 
flow of these devices. 

  Ability of the remote to operate the air filtration unit. 

 
It is very important that the hanging air filter be supported properly. Please follow these 
guidelines when planning where to mount the unit: 

  ONLY hang the air filter from the mounting brackets attach to the top of the unit. 

  Make sure that an electrical outlet with a properly grounded receptacle is available at the 

location you choose. DO NOT allow the power cord to become an interference or 
entanglement to this or other machines or people. 

  The hanging air filter must be supported by structurally solid components such as joists 

which must be capable of supporting a minimum of 2 times the weight of the unit. DO NOT 
attach the hanging air filter to items such as but not limited to sheet rock, press board or 
paneling. These materials cannot support the filter, and it will fall. 

  DO NOT use anchors such as are commonly used for mounting items to sheet rock. These 

anchors cannot support the weight of the filter long term and it may fall. 

Содержание AFS-1600

Страница 1: ...dustrial Holdings LLC does not assume and hereby disclaims any liability for any damage or loss caused by an omission or error in this Operator s Manual resulting from accident negligence or other occ...

Страница 2: ...AL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 UNPACKING AND CHECKING CONTENTS 10 Cleaning 10 INSTALLATION 11 Placement and Positioning 11 Filtering Performance 13 ASSEMBLY AND SET UP 14 ELECTRICAL 16 Power...

Страница 3: ...n notice to Seller of any suspected defect in the Goods prior to the expiration of the warranty period The original end user must also obtain a RGA from Seller prior to returning any Goods to Seller f...

Страница 4: ...es provided under this Agreement or at law or equity Attorney s Fees In the event legal action is necessary to recover monies due from Buyer or to enforce any provision of this Agreement Buyer shall b...

Страница 5: ...ption of the functional parts of the machine Capacity charts Setup and start up instructions Machine operation Scheduled maintenance Parts lists GENERAL NOTES After receiving your equipment remove the...

Страница 6: ...zardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a h...

Страница 7: ...nst objectionable or uncomfortable loud noises DUST HAZARD Wear appropriate dust mask Dust created while using machinery can cause cancer birth defects and long term respiratory damage Be aware of the...

Страница 8: ...or injury But even the best guard won t make up for poor judgment carelessness or inattention Always use common sense and exercise caution in the workshop If a procedure feels dangerous don t try it R...

Страница 9: ...ce at all times DO NOT reach over or across a running machine 10 Stay alert Watch what you are doing and use common sense DO NOT operate any tool or machine when you are tired 11 Check for damaged par...

Страница 10: ...ports Keep hair loose clothing fingers and all body parts away from openings and moving parts of the dust collector 24 DO NOT use the dust collector without a filter bag and dust collection bag in pla...

Страница 11: ...king for the support desk for purchased machines Tech Support handles questions on machine setup schematics warranty issues and individual parts needs other than die sets and blades For specific appli...

Страница 12: ...age painted surfaces Follow manufacturer s label instructions when using any type of cleaning product After cleaning wipe unpainted metal surfaces with a light coating of quality oil or grease for pro...

Страница 13: ...ted away from corners and heating cooling vents POWER SUPPLY PLACEMENT The power supply should be located close enough to the machine so that the power cord is not in an area where it would cause a tr...

Страница 14: ...tion of movement Consider the air flow of other air controlling devices such as HVAC and ceiling fans Try to have the air filter work with the air flow of these devices Plan for placement to allow the...

Страница 15: ...ement and positioning that will be complimentary to the first air filtration unit In short rooms with a larger volume may require two or more air filters to achieve proper filtering To calculate the r...

Страница 16: ...4 and tighten up See FIG 1 Fig 1 2 Installed the Inn Bag Filter NO 2 into the cabinet NO 4 See FIG 2 Fig 2 WARNING For your own safety DO NOT connect the machine to the power source until the machine...

Страница 17: ...the Installation guidelines and the placement and positioning guidelines install mounting hardware customer supplied into onto the support structure of the building 5 Verify that the mounting is into...

Страница 18: ...cs as indicated on the tool All line connections should make good contact Running on low voltage will damage the motor In the event of a malfunction or breakdown grounding provides a path of least res...

Страница 19: ...elow LENGTH AMP RATING 25ft 50ft 100ft 1 12 16 16 14 13 16 14 12 12 17 20 12 12 10 21 30 10 10 No WIRE GAUGE An undersized cord decreases line voltage causing loss of power and overheating All cords s...

Страница 20: ...18 18 WIRING DIAGRAM...

Страница 21: ...eration It is advised to turn the rocker switch Off during extended period of nonuse such as vacations The remote control has four control buttons ON Hour Speed OFF SPEED HOUR minus SPEED HOUR plus Th...

Страница 22: ...20 20 PARTS DIAGRAM...

Страница 23: ...AC1600 11 Motor 1 AC1600 12 Gasket 4 AC1600 13 Fix Board Ring 4 AC1600 14 Washer 1 4 x18x1 5 4 AC1600 15 Lock Nut 1 4 4 AC1600 16 Impeller 1 AC1600 17 Nut M8 1 AC1600 18 Hinge 2 AC1600 19 Front Cover...

Страница 24: ...22 22 Item Description Specification Qty AC1600 33 Connecting Cord 1 AC1600 34 Remote Control Bar 1 AC1600 35 Phillips Head Screw M4x6 2 AC1600 36 Phillips Head Screw M4x8 4...

Страница 25: ...ltration unit from the power supply 2 Release the latches on the end of the unit being serviced inlet or outlet end 3 Remove the cover 4 Remove the outer pre filter and then the inner bag filter from...

Страница 26: ...24 24 NOTES...

Страница 27: ...25 25 NOTES...

Страница 28: ...TOWOC WI 54220 PHONE 920 684 4990 FAX 920 684 3944 www baileigh com BAILEIGH INDUSTRIAL HOLDINGS LTD UNIT D SWIFT POINT SWIFT VALLEY INDUSTRIAL ESTATE RUGBY WEST MIDLANDS CV21 1QH UNITED KINGDOM PHONE...

Отзывы: