7. Install the feed handle and connect the trigger cord to the electrical box connector.
Oil Disposal
•
Used oil products must be disposed of in a proper manner following local regulations.
Accessing and Cleaning the Coolant System
The coolant pump and tank should be cleaned
frequently. If the coolant has not been used for a
week or longer, the coolant pump and tank
should be cleaned. Hot water will work to loosen
sticky dry coolant.
1. Remove the two socket head cap screws
and remove the coolant tray from the
machine stand.
2. Pour out the coolant from the tray.
3. Wash out the dirt and debris.
4. Remove and clean the filter. Replace if
needed.
5. Replace tray and secure with two socket
head cap screws.
6. Re-fill tray with coolant solution by pouring
coolant through the chip strainer.
Oils for Lubricating Coolant
Any 10:1 (water to coolant) solution will work, however we recommend Baileigh B-Cool 20:1
(water to coolant) biodegradable metal cutting fluid. It has excellent cooling and heat transfer
characteristics, is non-flammable, and extends blade and machine life. Each gallon of
concentrate makes 21 gallons of coolant.
Storing Machine for Extended Period of Time
If the Cold Saw is to be inactive for a long period of time, prepare the machine as follows:
•
Detach the plug from the electrical supply panel.
•
Release the head return spring.
•
Empty and clean the coolant tank.
•
Clean and grease the machine.
•
Cover the machine
Содержание CS-225M-V2
Страница 17: ...14 14 OVERALL DIMENSIONS Machine Dimensions when assembled 0 I REMOVE TO LOCK...
Страница 33: ...30 30 BLADE SELECTION CHART...
Страница 37: ...34 34 PARTS DIAGRAM...
Страница 38: ...35 35...
Страница 42: ...39 39 ELECTRICAL PARTS QF KM1 FR KA1 DCPS...
Страница 49: ...46 46 NOTES...
Страница 50: ...47 47 NOTES...
Страница 51: ...48 48 NOTES...