![Baicells Neutrino430 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/baicells/neutrino430/neutrino430_installation-manual_3455601010.webp)
10
Table 2-2: LEDs
LED
Color
Status
Description
PWR
Green
Steady on
Power is on
OFF
No power supply
RUN
Green
Steady on
Power is on
Fast flash: 0.125s on, 0.125s off
Data is transmitting
Slow flash: 1s on, 1s off
The cell has been activated
ACT
Green
OFF
Reserved
ALM
Red
Steady on
Reserved
Fast flash: 0.125s on, 0.125s off
S1 alarm
Slow flash: 1s on, 1s off
Other alarms
Table 2-3: Interfaces
Interface Name
Description
PWR
12V DC power supply interface
GPS
Port for optional external GPS antenna, N-female connector
WAN/PoE+
Gigabit Ethernet and PoE+ interface, used for debug and power supply.
OPT
Optical fiber interface, connect to external transmission network, used
for data backhaul.
2.3 Location & Environment
The Neutrino-430 can be installed on a ceiling or a wall. For the best signal coverage, place the
eNB in an unobstructed location. In addition to network planning, when determining where to
place the eNB, you need to consider the best location for signal coverage. Avoid locating the
eNB in areas where there may be extreme temperatures, harmful gases, unstable voltages,
volatile vibrations, loud noises, flames, explosives, or electromagnetic interference (e.g., large
radar stations, transformer substations). Avoid areas prone to impounded water, soaking,
leakage, or condensation. Environmental specifications are shown in Table 2-4
Table 2-4: Environment Specifications
Item
Description
Operating Temperature
-5°C to 40°C
Storage Temperature
-10°C to 50°C
Humidity
5% to 95%
Atmospheric Pressure
70 kPa to 106 kPa
Содержание Neutrino430