background image

 

33 

(1)

 

IPv4/IPv6: Select the protocol 

(2)

 

IP Address/Domain: IP Address or URL 

(3)

 

Count: number of ping count 

(4)

 

Fragment: yes or no 

(5)

 

Packet size: 56~1400 Bytes (non-fragment) 

 

2.10.7.3. Trace 

Figure 50: Trace Diagnosis Settings 

 

Settings: 

(1)

 

IPv4/IPv6: Select the protocol 

(2)

 

IP Address/Domain: IP Address or URL 

 

2.10.7.4. Result 

Figure 51: Diagnosis results 

 

Содержание ATOM OD15

Страница 1: ...1 ATOM OD15 CPE Installation Configuration Guide Model EG8015G M11 April 2020 Version 1 2...

Страница 2: ...ark of Baicells Technologies Inc Other trademarks mentioned in this document belong to their owners Revision Record Date Version Description SMEs Contributors Author Editor 18 Nov 2020 v1 0 Tang Houch...

Страница 3: ...Mixed Mode 15 2 6 3 WLAN Settings 2 6 4 Static Routes 16 2 6 5 DMZ 17 2 6 6 UPnP 17 2 7 LTE Menu 18 2 7 1 Connection Settings 18 2 7 1 1 Roaming setting 18 2 7 1 2 Default connection 18 2 7 1 3 Power...

Страница 4: ...31 2 10 6 1 Firmware Update 31 2 10 6 2 Restore Factory Settings 32 2 10 7 Diagnosis 32 2 10 7 1 TCPDump 32 2 10 7 2 Ping 32 2 10 7 3 Trace 33 2 10 7 4 Result 33 2 10 8 Backup Settings 34 2 10 9 Syste...

Страница 5: ...standards based product the Baicells equipment provides higher near line of sight nLOS and non line of sight NLOS signal penetration than other wireless technologies The high gain UE has a higher ante...

Страница 6: ...ll work as trunk mode so it can t assign IP address to any no trunk devices like PC so you have to Manual Configure the PC s IP address in the same broadcast domain e g 192 168 150 88 2 IDU ODU Mode W...

Страница 7: ...LTE TDD bands 42 43 48 Customization may be requested Complies with 3GPP Release 11 CAT12 15 1000 Mbps Ethernet interface Built in bipolar directional LTE antenna Power supply using Power Over Etherne...

Страница 8: ...he LEDs listed below Identity Description Color Status Description L S LTE network and USIM status Blue Off The UE is not connected to the network Steady On The UE is connected to the LTE network PWR...

Страница 9: ...ce With the CPE turned on and connected to the router access the GUI login page by opening a Web browser and entering http 192 168 150 1 Figure 2 Login Initially use the default Username admin Passwor...

Страница 10: ...er Throughput Statistics you will see downlink DL and uplink UL data rates for current throughput kbps average rates peak rates and total throughput The data is measured during a 3 second interval eve...

Страница 11: ...after every LTE connections Software Version ODU CPE operating software version Software Build Time Date and time the software was built SN Serial Number IMEI International Mobile Equipment Identity...

Страница 12: ...wnlink data throughput rate in Kbps UL The current uplink data throughput rate in Kbps Average The average DL and UL data throughput rates in Kbps for this CPE in the last 3 minutes Peak The peak DL a...

Страница 13: ...LAN Settings Enter the Network LAN DHCP Server enable IP address subnet mask DHCP range lease time UPNP enable Figure 8 DHCP Settings DHCP Static Leases settings can set by the host s MAC address Fig...

Страница 14: ...can be configured by Default router Data Mgmt Voip bear types Figure 10 WAN Settings 2 6 2 2 Router Mode When selected Router mode the CPE will worked at router mode it can dynamic update router tabl...

Страница 15: ...e CPE worked at Bridge mode the WAN ports address will bridge to LAN port and the LAN port will worked at trunk mode Figure 13 Bridge Mode 2 6 2 5 Mixed Mode Mixed mode can configured every APN with d...

Страница 16: ...ode 2 6 3 Static Routes Set Static routes of the CPE it can configure LAN or WAN port routes Gateway Destination Network and Route Subnet Mask in Current Settings show all activated static routes Figu...

Страница 17: ...ively you can enable Internet Control Message Protocol ICMP redirect error messages to support Layer 2 multicast features Figure 17 DMZ Settings 2 6 5 UPnP The Universal Plug Play UPnP function provid...

Страница 18: ...to other PLMN network else the CPE just can access the network PLMN same with the SIM card 2 7 1 2 Default connection If set always on the CPE will automatic access the LTE network after booting if s...

Страница 19: ...nnect to the Baicells CloudCore In the window Figure 42 you will select the APN number 1 8 enable it enter an APN Name select the type of IP addressing IPv4 IPv6 or IPv4v6 identify if it is the defaul...

Страница 20: ...n the band The CPE will routinely scan all channels in the band and all EARFCNs increasing the time it takes to connect compared to the other modes The band is dependent on the CPE model Dedicated EAR...

Страница 21: ...21 Figure 25 Dedicated EARFCN Figure 26 Cell Lock...

Страница 22: ...r s network Figure 48 Each operator has a unique Public Land Mobile Network PLMN number Locking the SIM prohibits the users from accessing another operator s network Figure 28 Throughput Statistics 2...

Страница 23: ...Settings 1 IP Port Filtering Mode Blacklist White list 2 IP Port Filtering Log Dropped enable disable 3 Destination IP Address the destination IP Address of the filter 4 Source IP Address the source...

Страница 24: ...nge of port 7 Source Port Range the range of port 8 Schedule Index Select box if can be schedule by APPs 9 Remarks 2 8 3 MAC Filtering Media Access Control MAC Filtering allows you to identify a list...

Страница 25: ...dden from accessing When you enable the filter a Settings window appears Enter the specific URL address users cannot access as shown in Figure 54 To add more URL addresses click on ADD After entering...

Страница 26: ...le disable 5 Block Syn Flood enable disable 6 SPI Firewall enable disable 2 8 6 Connect Limit Connect Limit feature is used to control the number of connections through the UE to a host device for exa...

Страница 27: ...set for a group schedule list like start from 2020 8 18 to 2020 8 20 as a index of the schedule Figure 37 Schedule List In previous Filter configurations you can select the schedule index like below f...

Страница 28: ...ort Forwarding Field Name Description WAN Port Range Enter the port number range for the remote device in the format of 1000 to 1500 LAN IP Address Enter the local host IP address The address must be...

Страница 29: ...ranslation for certain application layer control data protocols such as SIP TFTP PPTP L2TP and IPSeC You can enable the different types of application protocols by clicking on the check box next to th...

Страница 30: ...ork devices In the CPE GUI you can refresh the local time display using the SYNC WITH BROWSER button select the time zone that the CPE is in and enable NTP client to use the default or specified NTP s...

Страница 31: ...te Caution Do not power off the CPE or disconnect it from the computer during an upgrade To update upgrade the CPE to a different firmware version Figure 67 1 Download the image file from the Baicells...

Страница 32: ...utton The CPE will automatically reset its configuration to the factory default values Figure 47 Restore update 2 10 7 Diagnosis 2 10 7 1 TCPDump Figure 48 TCPDump Settings Settings 1 PC IP Address 2...

Страница 33: ...URL 3 Count number of ping count 4 Fragment yes or no 5 Packet size 56 1400 Bytes non fragment 2 10 7 3 Trace Figure 50 Trace Diagnosis Settings Settings 1 IPv4 IPv6 Select the protocol 2 IP Address...

Страница 34: ...Figure 52 Backup Settings 2 10 9 System Log System log is the debug information of the CPE when select the Setting it can Export or Clear Logs Figure 53 System Log Figure 54 System logs 2 10 10 System...

Страница 35: ...35 Figure 55 System Message Settings Figure 56 System Messages 2 10 11 SAS Settings Figure 57 System Message Settings...

Страница 36: ...boot of the CPE as shown in Figure 77 It can take several minutes for the reboot to complete After it reboots the CPE GUI will display the login screen Caution The reboot action will disrupt service F...

Страница 37: ...dio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not o...