How to Set Up the BA-440 DualBeam
The BA-440 DualBeam Reader can be easily configured for many
different applications. When communicating with the unit remember
these general rules:
1. Commands can be upper or lower case
2.
All
commands end with a carriage return (Enter key)
3. Any changes made are automatically saved - there is no separate
save command
4. If a command is not entered properly the reader will respond with
an “invalid command” message
Before getting into specifics here is the factory default configuration:
Configuration for BA-440 DualBeam Barcode Reader
Serial Number XXXXXXX-XX
Gain Channel Both
Label Format BAI-10
Vehicle Detect Mode Scan
Wiegand Bits 26
Wiegand Pulse Width 7
Wiegand Pulse Interval 7
Verify Vehicle Number Off
Minimum Reads 1
Communication Baud Rate 9600
Communication Parameters N81
Good Read Message "~F ~L~r~n"
Scan Detect Timeout 1000 ms
Good Read Pulse 1000 ms
Beeper Time 200 ms
Facility Code Shift Off
This configuration is generally used for applications where the BA-440
DualBeam will read decals and transmit them to a security panel or
telephone entry system through the 26 bit Wiegand communication
port. If you have any questions contact BAI at 800-528-9167.