GEN9-3
Cleaning process
Make sure no water in water tank
Dissolve the oxalic acid with hot water
put oxalic acid via steam outlet
Open the cleaning mode and wait
OPL shows on screen, switch off the
manual water drain ball valve
Finish cleaning
Trouble Shooting
E0: The temperature sensor open circuit.
Water level sensor failure, checking the control cable connection between the control panel to
steam generator is loose or not.
E02: The temperature sensor is Short circuit
E03: Signal transfer fault between main panel and sub-panel .
E04: Signal transfer fault between control panel and steam generator.
E12, E22, E32, E42: water inlet takes over 2 minutes
E13, E23, E33, E43: water inlet tank block.
E15, E25, E35, E45: Auto. high limit trips.