Error Code
Error Definition
Trouble-shooting Method
“04”
Throttle has not returned to
neutral position
Check if throttle has returned to neutral position,
unplug throttle and plug back in
“05”
Throttle Fault
Check the throttle
“07”
Overvoltage Protection
Check the battery voltage
“08”
Motor hall signal cable fault
Check the motor module
“09”
Motor phase cable fault
Check the motor module
“11”
Controller temperature sensor
failure
Check the controller
“12”
Current sensor failure
Check the controller
“13”
Battery temperature fault
Check the battery
“14”
Motor temperature fault
Check the motor
“21”
Speed sensor fault
Check installation position of speed sensor
“22”
BMS communication fault
Replace the BMS or battery
“30”
Communication fault
Check the controller connection