background image

11

 

    DISPLAY MANUAL 

DP C240.CAN

FUNCTIONS SETTING

 

“Unit”-unit switch between imperial 
and metric

Briefly press “+” or “-” to go to “UNIT”, 
and then briefly press ”ON/OFF” to switch 
between “Metric”/ “Imperial”, then briefly 
press ”ON/OFF” to confirm selection and 
save the setting and exit back to the “UNIT”. 
Press and hold “+” and “-” synchronously to 
save and exit back to the main interface,or 
you can also select “BACK” 

→ 

“EXIT” to exit 

back to the main interface.

 

“Metric”/“Imperial” switch

 

Auto Off

Briefly press “+” or “-” to go to “Auto Off”, 
and then briefly press ”ON/OFF” to select 
among “OFF”/“9”/“8”/“7”/“6”/“5”/“4”/“3”/“
2”/“1”ten levels, then briefly press ”ON/OFF” 
to confirm selection and save the setting and 
exit back to the “Auto Off”. Press and hold 
“+” and “-” synchronously to save and exit 
back to the main interface, or you can also 
select “BACK” 

 “EXIT” to exit back to the 

main interface.

Notice: “OFF” means this function is off, the 
unit is minute.

 

Brightness setting

Briefly press “+” or “-” to go to “Brightness”, 
and then briefly press ”ON/OFF” to select am
ong“100%”/“75%”/“50%”/“30%”/“10%”
five levels, then briefly press ”ON/OFF” to 

confirm selection and save the setting and 
exit back to the “Brightness”. Press and hold 
“+” and “-” synchronously to save and exit 
back to the main interface, or you can also 
select “BACK” 

 “EXIT” to exit back to the 

main interface.

Notice: “10%” is the weakest brightness and 
100%” is the strongest brightness.

 

Indication switch of output with cur-
rent or power

Briefly press “+” or “-” to go to “Power 
View”, and then briefly press ”ON/OFF”, 
then briefly press “+” or “-” to switch be-
tween Power and Current, then briefly press 
”ON/OFF” to confirm selection and save the 
setting and exit back to the “Power View”. 
Press and hold “+” and “-” synchronously to 
save and exit back to the main interface,or 
you can also select “BACK” 

 “EXIT”to exit 

back to the main interface.

Switch between Current and power

 

Light sensitivity setting

Briefly press “+” or “-” to go to “Sensitivity”, 
and then briefly press ”ON/OFF” to select 
among“0”/ “1”/“2”/“3”/“4”/“5” five levels, 
then briefly press ”ON/OFF” to confirm 
selection and save the setting and exit back 

Содержание DP C240.CAN

Страница 1: ...nt 1 Introduction 2 Overview drawing 3 Specifications 4 Functions overview 5 Normal indication area 6 Button definition 7 Normal operation 7 Functions setting 10 BESST connection 14 Error code definit...

Страница 2: ...Hardware version number B Down line as below 607K1Q7280001 607 Wire length and connector model is 750mm M5 2 K1 Internal identity number Q7280001 Production date is 28st July 2016 SN is 0001 Display P...

Страница 3: ...3 DISPLAY MANUAL DP C240 CAN OVERVIEW DRAWING OVERVIEW DRAWING...

Страница 4: ...voltage 36V 43V 48V DC Rated current 10mA Maximum operating current 30mA Power off leakage current 1uA Operating current supplied to controller 50mA Operation temperature 20 45 Storage temperature 30...

Страница 5: ...setting Indication for power assistance level with 6 levels 0 1 2 3 4 5 Indication for trip To indicate single trip dis tance total distance and remaining distance Multiple data indication Indication...

Страница 6: ...ODO max speed MAX average speed AVG remaining distance RANGE output power POWER energy consumption Cal riding time TIME Notice Calory data will only come out when the display recognize the sensor as t...

Страница 7: ...seconds briefly press means press for less than 0 5 second ON OFF Press and hold ON OFF button then display is working and offering power to controller On the contrary press and hold this button then...

Страница 8: ...gle trip distance Trip km total distance ODO km maximum speed MAX km h average speed AVG km h remaining distance RANGE km energy consumption CALORIES CAL KCal riding time TIME min real time output pow...

Страница 9: ...ition the frame of the symbol will flash at 1Hz when capacity is less than 5 means the battery needs to be charged USB charging Plug the USB cable to display and smart peripheral devices to charge but...

Страница 10: ...Error Code Wheel Power View Default Mode Unit Auto Off Brightness AL Sensitivity TRIP Reset Vibration BACK Press and hold button synchronously to enter into Display Setting interface and briefly pres...

Страница 11: ...fly press or to go to Brightness and then briefly press ON OFF to select am ong 100 75 50 30 10 five levels then briefly press ON OFF to confirm selection and save the setting and exit back to the Bri...

Страница 12: ...be reset simultaneously when you reset TRIP Vibration setting Briefly press or to go to Vibration and then briefly press ON OFF to select between ON and OFF ON means vibration button is on OFF means...

Страница 13: ...o to Battery Info and then briefly press ON OFF to enter then briefly press to review the battery data from b01 b04 b06 b07 b08 b09 b10 b11 b12 b13 d00 d01 d02 dn then briefly press ON OFF to exit bac...

Страница 14: ...umber and hardware number If the display show Write OK it means it is successful for BESST BOX to write basic information into the display The informa tion includes customer s number wheel size speed...

Страница 15: ...sor inside battery Bring your Pedelec to your dealer or to a specialist to have the error fixed 21 Fault with wheel speed detecting sensor Bring your Pedelec to your dealer or to a specialist to have...

Страница 16: ...h M3 screw A Display unit B Support bracket C M3 screw Pull out the clamp of the support bracket and put it around the handlebar and then fix it with M3 screw 1N m D Clamp E Hex socket screw M3 30 Plu...