Installation/User Manual
17
Model
BPE600-127V
BPE600-240V
Input Data (DC)
Operation Voltage Range
20V-55V
Startup Voltage
20V
Maximum DC Short Circuit Current
Output Data (AC)
Nominal Output Voltage
127/240V
Nominal Output Current
2.5A/4A
Default/Protect Output Voltage Range
184-265V
Extended/Reconnect Output Voltage Range
95-155V
184-265V
Nominal Output Frequency
Extended/Reconnect Output Frequency Range
50Hz/45-55,60Hz/59.3-60.5
Total Harmonic Distortion
<3%
Efficiency
Night Power Consumption
50mW
Mechanical Data
Storage Temperature Range
-40 °C to +85 °C
Weight
2.2kg
Enclosure Rating
IP65
Wet Locations Classification
For Wet Locations
Relative Humidity Ratings
0-95%
Certificates
UL1741,VDE0126,VDE4105,IEC62109,CE
© All Rights Reserved
Pollution Degree Classification
PD3
Communication
Powerline
Operating Ambient Temperature Range
-40 °C to +65 °C
Max. Inverter Efficiency
96.5%
Power Factor
>0.99
Default/Protect Output Frequency Range
50Hz/45-55,60Hz/59.3-60.5
Maximum Output Power
600W
Maximum Input Voltage
60V
BPE600 Microinverter Datasheet
MPPT Voltage Range
25V-55V
Maximum Input Current
10.4A x 2
Dimensions (W x H x D)
187mm X
163mm X 29mm
Cooling
Natural Convection - No Fans
Maximum Altitude Rating
All Data At This Technical Specifications Has Been Tested Under <2000m
50Hz/60Hz Auto Sense
13A
95-155V