background image

General description 

November 2016

 

LMS_FMS Compact_BA_02_0163

 

Page 3

 

2.3

 

Connections 

01 

PE 

 

 

16 

Valve 3 - 24VDC/2A 

RS232 Port for software, 

external printer or  

Barcode scanner 

 

 

 

02 

 

17 

Valve 3 - GND 

03 

L1 230VAC/50Hz 

 

18 

Pulse Input 3 + 

 

 

 

 

19 

Pulse Input 3 GND 

04 

Valve 2 -24VDC/2A 

 

 

 

 

05 

Valve 2 - GND 

 

20 

GND 

06 

Pulse Input 2 + 

 

21 

+12VDC 

07 

Pulse Input 2 GND 

 

22 

+24VDC 

 

 

 

 

 

 

 

08 

Valve 1 - 24VDC/2A 

 

23 

Emergency Key 

09 

Valve 1 - GND 

 

24 

Emergency Key 

10 

Pulse Input 1 + 

 

25 

Pump Output Relay 5A/30VDC 

11 

Pulse Input 1 GND 

 

26 

Pump Output Relay 

 

 

 

 

 

 

 

12 

Valve 4 - 24VDC/2A 

 

F1  Fuse 1.0A SB 250V  

5VDC  

13 

Valve 4 - GND 

 

F2  Fuse 2.0A SB 250V  

12/24VDC 

14 

Pulse Input 4 + 

 

F3  Fuse 6.3A SB 250V  

Int.Printer 

15 

Pulse Input 4 GND 

 

F4  Fuse 2.0A SB 250V  

230VAC 

Note: 230 VAC standard, optional 115 VAC 

 

 

 

 

 

 

 

 

 

 

 

RS232 serial port  

Ext. printer / PC software / Barcode reader 

RXD 

= Pin 3 

TXT 

= Pin 2 

GND 

= Pin 7 

 

Flash tool connection 

For firmware update only for service 

 

 

RS232 serial port 

 

Flash tool 

connection

 

Содержание Oval Gear FMS Compact

Страница 1: ...FMS Compact Fluid Management System LMS_FMS Compact_BA_02_0163 November 2016 User manual Firmware v3 7 until v5 16...

Страница 2: ...5 Installer menu PIN 9999 default 7 6 General system reset 11 7 Printer 12 7 1 Internal ticket printer 12 7 2 Internal or external ticket printer 12 7 3 External report printer 12 7 4 Configuration e...

Страница 3: ...ass IP 42 and needs to be protected against dripping water water oils etc Setup operation Adjust only those controls that are covered by the operating instructions Improper adjustment of other control...

Страница 4: ...rcode reader Baudrate 9600 Parity none Databits 8 LF CR Firmware update With special serial adapter Fuses F1 Fuse controller 1 00 AmT SB 250V F2 Fuse 12 24VDC 2 00 AmT SB 250V F3 Fuse int printer 5 00...

Страница 5: ...DC 2A 1 23 Emergency Key 09 Valve 1 GND 24 Emergency Key 10 Pulse Input 1 25 Pump Output Relay 5A 30VDC 11 Pulse Input 1 GND 26 Pump Output Relay 12 Valve 4 24VDC 2A 4 F1 Fuse 1 0A SB 250V 5VDC 13 Val...

Страница 6: ...Number Alphanumeric entry max 15 digits Confirm with OK Select fluid type on keypad or with arrow keys Confirm with OK Enter the requested quantity in liters Confirm with OK The system is now ready t...

Страница 7: ...OK Note The external printer must be activated Stock Level Will print the actual stock levels Choose PRT to print or Quit to return Prod Delivery Fluid delivery can be added to the current stock tank...

Страница 8: ...is displayed if the entered PIN number has already been allocated to another operator Add new User To add a new user Enter new user name Enter PIN number with key Enter PIN number on keypad Confirm wi...

Страница 9: ...return with Quit Only firmware v4 0 and later If the Set MinStock is set to zero the warning is deactivated Set Mode Normal preselection mode or free dispense mode Preselect 1 Free dispense 2 Select a...

Страница 10: ...9999 can be changed Enter the PIN number and confirm with OK or return with Quit Error is displayed if the entered PIN number has already been allocated to another operator Hose Calib Calibration or...

Страница 11: ...for each hose No sub menu Setup Printer Printer selection 0 No printer assigned 1 Internal ticket printer 2 External printer 3 Internal and external printer Clear Transact Deletes all stored transact...

Страница 12: ...ware v5 0 Unit 0 Liter 1 kg 2 m3 3 Gal Special Mode With Special Mode 0 the system will work as a standard Fluid Management System Mode 1 and 2 are customized dispense scenarios See chapter 9 Only fir...

Страница 13: ...time exceeded X Only firmware v5 10 and later 6 GENERAL SYSTEM RESET This function will reset and erase the FMS Compact only firmware v3 9 and later NOTE System will be set to factory default data Pr...

Страница 14: ...xternal report printer 7 4 Configuration external printer RS232 Baudrate 9600 Databit 8 Parity None StopBit 1 Connection 25 pole D SUB RXD PIN 3 TXD PIN 2 GND PIN 7 25 05 11 15 12 H Mueller 458534 SAE...

Страница 15: ...cannot be used anymore Connection RS232 D Sub 25 pole 9600 Baud 8 DataBit ParityNone 1 Stop Bit Recommended barcode scanner Datalogic Gryphon Datalogic Magellan 1000i Barcode sample PIN number 1111 CR...

Страница 16: ...07 40 04200 00 L 22 03 07 15 31 MR MUELLER 1234 SAE15W30 1 Liter 000003 50 Ticket printout 22 03 07 16 24 MR MUELLER 1234 Product one 1 Liter 000007 40 Ticket printout Quit OK Good day MR MUELLER STOP...

Страница 17: ...azol 9888 PO 123456789012 Fuel Gal 5000 Product 1 1 Gal 000001 86 Ticket printout STOP Button No flow detected the attached valve has been closed manually Can be adjusted in menu Inactive Timeout The...

Страница 18: ...wable dispense time has been exceeded to be defined in Menu Dispense TO Page 11 Pulsating beep tone will start Only firmware v5 10 and later An unexpected pulse input arrived while the solenoid valve...

Страница 19: ...OING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES WHATSOEVER INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES EXCEPT OF TITLE OF MERCHANTABILITY AND FITNESS FOR A PARTIC...

Страница 20: ...www badgermeter de...

Отзывы: