3. Tap the 

ORION Field Application

 icon with the stylus or use the Arrow Keys until

the 

ORION Field Application

 folder is highlighted and press 

Enter

 on the

Keyboard.

4. Verify that the date, time and time zone are correct and tap 

OK

 on the left side of the

toolbar or press the 

Left

 button on the keypad.

Содержание ORION ME

Страница 1: ...Making Water Visible Published by BMI Training Support BTR UM 02333 EN 02 January 2018 Trimble Ranger 3 with ORION ME Training Manual...

Страница 2: ...Trimble and ME Page 2 January 2018...

Страница 3: ...rmeter com Fax 888 371 5982 Topic Page About this Guide 4 Automated Meter Reading ORION AMR System 5 Orion Hardware Basics 6 Endpoint Installation Guidelines 9 Trimble Ranger 3 12 Getting Started 13 O...

Страница 4: ...creens that you need to select or choose by clicking a button highlighting checking a box or another similar means are in bold text and capitalized in the manual Example Click the View Report button N...

Страница 5: ...anty Prorated With an Automated Meter Reading AMR or mobile system ORION endpoints transmit meter reading and event data via radio frequency to a mobile receiver or transceiver when the device is with...

Страница 6: ...ME Page 6 January 2018 ORION Hardware Basics Meters M Series Electromagnetic Flow Meters E Series Ultrasonic Meters Gas Meters Recordall Compound Meters Recordall Disc Series Meters Recordall Turbo Se...

Страница 7: ...to be applied to the endpoint meter reading The register resolution for high resolution encoders is based on the meter model and size encoder type unit of measure and the Badger Meter endpoint that i...

Страница 8: ...E endpoints are easily upgraded from mobile to fixed network data collection without rolling a truck or reprogramming the endpoint preparing you for the future ORION CE endpoints are one way water end...

Страница 9: ...ude lid design foliage below grade mounting and metal objects either in the path or near the desired line of site To maximize propagation of the radio signal refer to the ORION Water Endpoint Installa...

Страница 10: ...bracket helps for indoor installations such as a floor joist If the meter is installed indoors a radio endpoint could be mounted outdoors on the outside of the building The ORION Remote Wall Mount En...

Страница 11: ...ough a nonmetal pit lid is recommended for maximum propagation of the radio signal For more detailed information please visit our website at www badgermeter com to review the ORION Water Endpoint Inst...

Страница 12: ...ON User Manual which can be found at www badgermeter com Features of the Trimble Ranger 3 The ORION transceiver in the handheld listens for transmissions sent from an ORION endpoint and matches the un...

Страница 13: ...keypad allows basic data entry as well as access to optional applications such as flashlight and camera To turn the handheld on press and release the green power button Note Pressing the green power...

Страница 14: ...lays 1 Using the stylus tap the Windows icon in the lower left corner of the screen or using the keypad press the Windows icon to expand the Start menu 2 Using the stylus tap the Badger Meter Applicat...

Страница 15: ...n icon with the stylus or use the Arrow Keys until the ORION Field Application folder is highlighted and press Enter on the Keyboard 4 Verify that the date time and time zone are correct and tap OK on...

Страница 16: ...h the stylus or press the center button or Enter on the keypad 6 Use the keypad to enter a 3 to 5 character personal identification number PIN then tap OK on the left side of the toolbar or press the...

Страница 17: ...ge 36 for instructions on how to change the display fields Additional information on the account record screen includes Technology Endpoint Serial Number Service Serv1 Serv2 etc Progress Percentage of...

Страница 18: ...ial number Endpoint radio is paused or stopped Account record is not loaded into the handheld Handheld is out of range of the endpoint Obstructed line of site between the handheld and endpoint Auto Mo...

Страница 19: ...Processing When an ORION endpoint passes a Tamper flag back to the Trimble the Tamper processing options automatically open on the Trimble Tap on Trouble Code to select a pre defined message to send...

Страница 20: ...read to your billing units The route management software will not apply any resolution logic to a manually entered reading High Low Alerts In this example the software is notifying you the reading is...

Страница 21: ...f the toolbar to bring up a list of commonly used options Use the Arrows on the keypad to scroll to Clear Reading and press Enter or use the stylus to tap on Clear Reading You may also choose to tap t...

Страница 22: ...ess initiated by the meter Collector function reader Applies to select accounts chosen Select ORION ME accounts Data transfers to BEACON as part Data transfers to BEACON as part of Sync feature of Syn...

Страница 23: ...mple Historic Interval Data 30 days of hourly reads Processing Tap the correct Test Circle The handheld software will notify the user when the work item is complete Note Extended Status is automatical...

Страница 24: ...k access to commonly used menu items Most quick keys are identified by yellow text above the corresponding alpha key BB Add Remove Bookmark CC Page through Bookmarked Accounts DD Change Read Direction...

Страница 25: ...ark CC Pages through Bookmarked Accounts Note There is a search option to see all bookmarked accounts Read Direction DD Changes Read Direction Tap Yes to read the route in reverse order To return to t...

Страница 26: ...eter reading is expected to fall between the High and Low range Note If the odometer reading entered by the meter reader does not fall within the expected range the account record is flagged with high...

Страница 27: ...es to the next account record regardless if it is read or unread In Auto Advance Mode the handheld software advances to the next unread meter Messages Fn N Opens the Edit Extended Comment screen and a...

Страница 28: ...ount record Reader Codes RR Reader codes are predefined flags used to notify the office about a specific account record Up to 3 Reader codes can be attached to a single account record by using the sty...

Страница 29: ...rch by Last Name Tap Last Name or use the up and down arrows on the handheld keypad to highlight Last Name and press Enter or tap Select Use the keypad to type the Search By value in the text box For...

Страница 30: ...een Search criteria can be easily changed For example tap Contains if you would like to change the criteria to Starts With or Ends With Tap List to change the view type to Grid or Paged results Tap th...

Страница 31: ...tting a meter read Unread Meter UU Unread automatically advance the account record screen to the next unread meter Reminder SS Search has an option to display all Unread Meters Skipped Meter WW Cycles...

Страница 32: ...u The Menu button on toolbar allows access to commonly used functions such as Search Clear Reading Select Route Progress Quick Read In route reading the Quick Read option is helpful when the ORION end...

Страница 33: ...ORION Field Application Settings Menu KK to access the Settings menu Settings will determine how the handheld will function during the meter reading cycle We will discuss each settings option Hardware...

Страница 34: ...l port on the bottom of the handheld COM 4 is used to identify an external ME transceiver Note More detailed settings definitions can be found in the back of this guide as well as in the ORION Field A...

Страница 35: ...uals the high or low value Manual Entry Exception Processing Configured to accept the reading acknowledge the reading or reenter the reading Show Previous Read Route Boundary Alerts Allows the user th...

Страница 36: ...ute file is configured to transfer wirelessly Auto Transfer On Dock This option is used when the route file is configured to transfer by network cable Handheld Device Name A unique name is required fo...

Страница 37: ...Trimble and ME Page 37 January 2018 Appendix...

Страница 38: ...tting the Comm Mode button makes the Data Sync process between the Trimble handheld and BEACON software as easy as a press of a button Follow the steps below to complete the setup 1 Click on the windo...

Страница 39: ...Click on the Buttons Option 5 Scroll until you find the COMM MODE button and click on it to select 6 Click on the Assign a Program dropdown and scroll until you find the Start COMM Mode option and cli...

Страница 40: ...trademarks appearing in this document are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product o...

Отзывы: