Programming
Page 11
March 2017
SEN-UM-01662-EN-05
6 . Click
Poll Now
to update the current values .
7 . Select
Configuration
>
Parameters
to
open the
Parameters
screen . You can also select the
Parameters
button . See
Figure 14: Select Parameters
8 . Program the wireless receiver using the Parameters screen in
as a reference .
a. Serial Number
: Enter the serial number of the
wireless receiver . ‘
b. Volume Unit
: Select the desired volume unit for scaled
output pulses .
c. 1 Pulse
: Enter the desired volume per scaled
output pulse .
d. Pulse Width
: Enter the scaled output pulse width .
OTEE:
N
The default pulse width is 50 milliseconds .
Minor variation in pulse width may be
required, depending on controller interface .
e. Lost Signal Recovery
: Configure this section
depending on the application requirements . If
checked, the data accumulated during a lost signal
period will be recovered . See the instructions on the
screen for more information .
f. Send
: Click to calibrate the wireless receiver with the
information that was entered .
g. Refresh
: Click to see the current programming .
h. Defaults
: Click to enter the factory default
programming .
OTEE:
N
Selecting
Defaults
overwrites all settings .
i. Exit
: Click to exit and close the Parameters screen .
Figure 15: Receiver parameters
9 . Click the
X
in the top right corner of the screen to exit the programming software .