Flow Sensors

Wireless Flow Sensor System
Series 228PV

User Manual

SEN-UM-01662-EN-05 (March 2017)

Содержание Impeller 228PV150U Series

Страница 1: ...Flow Sensors Wireless Flow Sensor System Series 228PV User Manual SEN UM 01662 EN 05 March 2017...

Страница 2: ...RF Receiver 4 Installation 5 General 5 Wireless 228PV Plastic Tee Sensor and Transmitter Mechanical Installation 6 Wireless Receiver Mechanical Installation 6 Antenna Installation 7 Wireless Receiver...

Страница 3: ...harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation of the device In accordance with FCC Regulations Code of Federal...

Страница 4: ...The output signal to the RF transmitter is a scaled output pulse An internal lithium battery provides power for the flow sensor and is encapsulated to ensure moisture resistance Wireless ORION RF Tran...

Страница 5: ...owed to ensure maximum system accuracy 1 Choose a location along the pipe with a length equivalent to 10 pipe diameters upstream and 5 pipe diameters downstream of the sensor which are free of flow di...

Страница 6: ...ess transmitter cap from the wireless transmitter body by unscrewing it in a counterclockwise direction 7 Insert the wireless transmitter body through a minimum 1 625 inch 41 mm hole in the valve box...

Страница 7: ...osure that houses the RF receiver The antenna can also be installed remotely from the enclosure to be within a clear line of sight of the RF transmitter Antenna Kits Antenna kits are an optional acces...

Страница 8: ...iver Electrical Installation Per standard wiring practices turn off the power before making any wire connections The terminal strips have removable plug in connectors to make wiring easier 3 32 in Fla...

Страница 9: ...erated in the 4 5 second update window the RF receiver will simply delay the next update until the pulse string has been completed Sensor Model 228PV200W 1231 000 Line Size 2 inches Gallons per Intege...

Страница 10: ...evices The installation software can be found under Support Resources Software on the website at www badgermeter com Wireless Receiver Programming To change the settings of the wireless receiver use t...

Страница 11: ...width NOTE N The default pulse width is 50 milliseconds Minor variation in pulse width may be required depending on controller interface e Lost Signal Recovery Configure this section depending on the...

Страница 12: ...Frequency GPM K Offset to calculate sensor frequency at any flow rate within its operational range Factory settings for K and Offset values are normally changed only when installing the sensor in a di...

Страница 13: ...main menu Then select Sensor from the Device Type drop down menu Figure 16 Select Device and Device Type 4 Select Configuration Set Comm Port from the main menu to open the Comm Settings window Selec...

Страница 14: ...lected in Pipe Size If Other Unlisted was selected enter the desired values in each field c Rate Unit Select the desired unit for flow rate display d Pulse Output Control Enter the desired volume per...

Страница 15: ...scale over recommended design flow range Repeatability 0 5 of full scale over recommended design flow range Maximum Operating Temperature 32 150 F 0 65 C CSA approved Temperature Rating 140 F 60 C Sen...

Страница 16: ...ia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus Badger Meter Europe ul Korfantego 6 44 193 Knur w Pol...