Location

Page 2 

November 2017

DSY-UM-02471-EN-01

LOCATION

The HR-RED can be installed indoors or outdoors. 

MPORTANT

I

While the HR-RED electronics and battery are environmentally sealed and suitable for outdoor installation, the wire  

terminals are not sealed from moisture. The unit, therefore, should NOT be installed in locations below grade level or in a 

submersible environment.

INSTALLATION GUIDELINES

• 

Always use enough cable wire. It is better to have a little excess than to go back and rewire.

• 

If the HR-RED is replacing an existing RED or Read-o-Matic® display, do not use the existing interface wiring. Replace it 

with new wire.

• 

When installing the unit on buildings with a stone or masonry exterior, the use of masonry cleats and fasteners is 

required. After determining the location, use a 3/16 in. carbide-tip masonry bit, and drill two mounting holes. Insert 

masonry cleats and attach the HR-RED with round head screws. 

• 

After wiring, if the unit does not operate, check for bare wires touching each other. 

• 

If you secure the cable with staples, be careful not to pierce the outer sheath since this could short out the unit.

INSTALLING THE HR-RED

OTEE:

N

For best results the HR-RED should be mounted at eye level in an easily accessible location. Choose a location within 

the limits of the meter cable. Maximum cable length between the meter and the HR-RED is 2000 feet.

1.  Using the HR-RED base as a template, mark the mounting hole locations on the wall where the unit will be mounted.  
2.  Drill the mounting holes at the marked locations and secure the base to the wall. (Mounting hardware is 

customer supplied.)

OTEE:

N

Avoid mounting the HR-RED on any type of loose siding since this may lead to wire breakage or other 

potential problems. 

3.  Drill a 3/16 in. (5 mm) entry hole in the wall of the structure to accommodate the meter cable. 
4.  Pass the meter cable with the flying leads through the entry hole to the HR-RED.
5.  Cut the meter cable to the proper length at the HR-RED, allowing sufficient cable for the connection. 

OTEE:

N

Allow sufficient length so the cable hangs loosely, not taut, where it enters the building to eliminate the 

possibility of rainwater running along the wire into the building. 

6.  Place the strain relief ring from the installation kit around the meter cable and secure it about 1-1/2 in. (38 mm) from 

the end. 

7.  Use a cable stripper to remove the outer sheath of the meter cable, up to the strain relief ring, to expose the three 

lead wires and the non-insulated shield wire.

8.  Strip about 1/2 in. (13 mm) of insulation from the ends of the meter lead wires. Make sure you do not cut/damage the 

wires or the wire insulation. At this point, you can cut off the exposed shield wire, even with the meter cable outer 

sheath, to keep it out of the way.

9.  Join the meter wires and the HR-RED wires using the connectors from the installation kit, one for each pair of wires. 

OTEE:

N

Polarity must be observed when connecting the meter and the HR-RED wires: 

red

 (power/clock) to 

red

green

 (data) to 

green

,

 

black (ground) to black

Meter Cable with Flying Leads

RED - Power

GREEN - Data

BLACK - Ground

HR-RED

RED 

GREEN 

BLACK 

Содержание HR-RED

Страница 1: ...r vaults or dangerous industrial locations are ideal for the HR RED For additional information and product specifications refer to the HR RED product data sheet available in the Resource Library at www badgermeter com STANDARD COMPONENTS HR RED Kit 64466 002 Strain relief ring Three 3 connectors for wires Torx seal screw Unit of measure adhesive label Installation Tools The following customer supp...

Страница 2: ...here the unit will be mounted 2 Drill the mounting holes at the marked locations and secure the base to the wall Mounting hardware is customer supplied NOTE N Avoid mounting the HR RED on any type of loose siding since this may lead to wire breakage or other potential problems 3 Drill a 3 16 in 5 mm entry hole in the wall of the structure to accommodate the meter cable 4 Pass the meter cable with ...

Страница 3: ...e When attached to Badger Meter high resolution encoders or high resolution E Series Ultrasonic meters the unit is designed to provide the same output resolution as the encoder up to 9 digits for Badger Meter products It also displays the encoder serial number To conserve battery life the HR RED is awakened only when the internal acoustic switch is activated Tap the target circle on the front of t...

Страница 4: ...g C Office C209 Dubai UAE 971 4 371 2503 Slovakia Badger Meter Slovakia s r o Racianska 109 B 831 02 Bratislava Slovakia 421 2 44 63 83 01 Asia Pacific Badger Meter 80 Marine Parade Rd 21 06 Parkway Parade Singapore 449269 65 63464836 China Badger Meter 7 1202 99 Hangzhong Road Minhang District Shanghai China 201101 86 21 5763 5412 Switzerland Badger Meter Swiss AG Mittelholzerstrasse 8 3006 Bern ...

Отзывы: