Badger Meter Hedland EZ-View Скачать руководство пользователя страница 2

2.  Place the piston inside the meter, over the cone as shown in 

Figure 5

.

Figure 5: Piston installed

SPRING INSTALLATION

1.  Install the spring into the body with the double coils up.

Figure 6: Spring double coils

2.  Secure the already fastened fitting of the meter in a vice or 

dedicated fixture.

Figure 7: Meter in a dedicated fixture

3.  Place the second fitting into the open end of the meter and 

hand-thread for a few turns, making sure that it is flat/level.

4.  Once the fitting is started, use a spring depressor to keep the 

spring from hindering the fitting from fully seating.

Figure 8: Spring depressor

5.  Using appropriate torque wrench with locknut socket, 

tighten the fitting to 85…90 ft·lb.

Figure 9: Torque wrench

6.  Flip the meter over in the vice and tighten the second fitting 

using the appropriate torque wrench.

NOTE:

N

After installing the second fitting, visually inspect 

both ends of the unit to make sure that the o-ring has 

been properly installed and is properly seated. If it is 

protruding out of the o-ring groove, remove the fitting, 

remove and inspect the o-ring (replace with a new 

o-ring if there are any nicks, cuts or scrapes) and reinstall 

making sure that it is seated properly.

NOTE:

N

After assembly of the meter, visually inspect both ends 

of the meter for uniformed circumferential lines of 

contact between the o-rings and meter body.

FULLY ASSEMBLED METER

Figure 10: Assembled meter