TROUBLESHOOTING
Dispense Keypad Error Messages
These error messages can be displayed by the Dispense Keypad . The associated action to reset the system is listed behind .
Message
Messages at the Dispense Keypad
Hose active hit hose reset
The selected meter currently has a dispense order in waiting to be processed, complete
the active order . Press
RESET
.
WO refused
The entered work order number is not valid and has been refused by host or FMS software .
Master is down
The master does not respond to a request from the Dispense Keypad
PC is down
The FMS software (KPS) is not responding to the Master Keypad . Only if WO validation PC is
activated .
HOST is down
The HOST (DMS) is not responding to the Master Keypad . Only if “WO Validation HOST” is
activated . Press
RESET
.
Host or PC is occupied
Master keypad is occupied by another job . Press
RESET
.
Wrong hose for fluid
The meter selected is not a valid meter for the fluid assigned for this WO .
↑ ↓
RF communication is in progress, please wait (10 sec) .
Meter Error Codes
The meter has several Error Codes that may display . These provide indication, at the meter, that there is an error in
communication between the meter and keypad .
Message
Messages at the Meter
F01
The meter radio is not working .
To clear the error, press the
RESET
button on the meter .
F02
The meter is not configured to a keypad .
To clear the error code, press the
RESET
button on the meter .
Verify that the meter radio address is configured properly .
F03
System busy .
To clear the error, press the
RESET
button on the meter .
F08
Meter lost connection to network .
Out of range—network connection lost .
Keypad not powered .
Meter moved out of range of keypad .
F09
Meter not connected to a network .
First time being powered up .
Network selected is not available .
SF0
(Scale Factor 0)
The Scale Factor setting for the meter is set to 0 .000 .
To input a valid Scale Factor for the meter follow the instructions in the Change Factory Settings section
of this manual .
All other
Error Codes
Are for factory purposes only .
To clear the meter, press
RESET
.
Press
RESET
once more at the meter .
Parts Department User Menu
Page 55
December 2014
FMS-UM-01200-EN-01