Batch (Auto) Mode
1. Program the meter to auto mode using option 1-6 in

the batch-programming mode. (See Programming the
Batch Function)

2. Pull the trigger to begin the flow. The valve will

automatically lock in place, even though the trigger will
fall back to the closed position. The flow will
automatically shut off when the desired batch size has
been dispensed.

The valve will always lock in the maximum open position.
Note: At any time during the operation of the meter, the

flow may be stopped by pressing the red 

 button.

This will mechanically close the valve, stopping the flow.
Batching may be resumed by pulling the trigger.

3. The user has the option to top off at the end of the batch.

To top off the tank, simply pull the trigger to begin the flow
and release when the desired amount has been
pumped. If in count down mode the additional amount
will be shown on the display. If in count up mode, the
additional amount will be added to the total amount
dispensed.

4. Press the 

 button when finished to reset the

meter. It is now ready for the next batch.

Do NOT press 

 before topping off. The meter will

begin a new batch.

Normal Operating Mode Functions

History
This option allows the user to review the previous five
batches dispensed with meter.

1. Press and hold the 

/ HISTORY button to view the

five previous batches. The batches will be displayed on
the screen one at a time, starting with the most recent,
and cycling through to the oldest. The batches will
continue cycling as long as the HISTORY button is held
down.

The display will automatically return to the normal
operating screen 2 seconds after releasing the
HISTORY button.

QT

HISTORY

HISTORY

..

History Function

Note: The history cannot be erased, unless the user
changes from English units to metric units or from metric to
English units. (See Changing Factory Settings.)

Flow Rate
This option allows the user to see the instantaneous rate
at which oil is flowing through the meter.

While oil is flowing through the meter, press and hold the

 / FLOW RATE button, and the rate of flow will

appear in the bottom right corner of the display. As long
as the button is held down, the flow rate will remain on
the display. Releasing the button will return the display to
the normal operating screen.

QT

,,

GPM

GPM

GPM

.

Flow Rate Function

Note: The flow rate can only be displayed if fluid is flowing
through the meter.

Total
This option allows users to see the accumulated total as
well as the resettable total.

Press and hold the  

 button while in normal

operating mode to see the accumulated total. Continue
holding and after three seconds the screen will change to
the resettable total, which displays the total fluid
dispensed since the resettable total was last set back to
zero.

Press the 

 button while viewing the resettable total

to set the resettable total back to zero. Release the  

button to return to the normal operating screen.

Note: The accumulated total cannot be reset, unless the
user changes from English units to metric units or from
metric to English units. (See Changing Factory Settings.)

 

RESET TOTAL 

Total Function

Содержание EPM

Страница 1: ...llation Operation Manual Bulletin No IOM 079 01 PartNo 53400 079 February2001 Model EPM Electronic Preset Meter Advanced Series IMPORTANT This manual contains important warnings and information READ A...

Страница 2: ...xceed the maximum working pressure level of the lowest rated system component 8 Use only extensions and nozzles that are designed for use with this equipment 9 Use only fluids and solvents that are co...

Страница 3: ...Place the hose end in a waste container Make sure hose is secure so no fluid will leak during flushing 5 Slowly open the dispense valve and allow enough oil to pass through to ensure that the system...

Страница 4: ...QT AUTO Auto Mode Option 1 2 The meter is now ready to be programmed The 1 before the colon will be flashing This is the option icon Option 0 is for manual mode see Manual Mode Options 1 5 are for au...

Страница 5: ...ldest The batches will continue cycling as long as the HISTORY button is held down The display will automatically return to the normal operating screen 2 seconds after releasing the HISTORY button QT...

Страница 6: ...urely replace the rubber o rings surrounding the battery cap and screws to prevent liquid from leaking into the battery compartment The o rings are reusable indefinately however new o rings can be pur...

Страница 7: ...ars without being detected Changing the scale factor can adjust the meter to compensate for that loss The meter multiplies each pulse by this number to correct the accuracy when it converts to the spe...

Страница 8: ...bar Operating Temperature Maximum 120 F 50 C Operating Temperature Minimum 20 F 5 C Accuracy Non Approved Version 0 5 0 5 Accuracy Approved Version 0 4 0 3 1 to 10 lpm 5 Digit LCD Display 10 mm High...

Страница 9: ...ITEM PART DESCRIPTION PART NUMBER 1 Top Case with Screws 64103 002 2 Keypad 63802 001 3 PCB Assembly Non Approved with Screws 64103 001 4a Bare Meter NPT 63897 001 4b Bare Meter BSPP 63897 002 1 2 3 4...

Страница 10: ...PART DESCRIPTION PART NUMBER 1 Battery Door with Screws 64103 004 2 Bottom Case with Screws 64103 003 3 Detent Ball 63841 001 4 Solenoid 63879 001 5 O Ring BatteryDoor 55300 043 6 O Ring BatteryCompar...

Страница 11: ...ART DESCRIPTION PART NUMBER 1 Valve Assembly 63997 001 2 Screw Sems Type 63253 001 3 HousingCover 63810 001 4 O Ring 55300 035 5 Gear Service Kit with O Ring 62896 001 6 Trigger Assembly 64103 005 2 5...

Страница 12: ...414 355 7499 Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product or system specifications without notice except to the extent that an out...

Отзывы: