Installation & Operation Manual

OPERATION

The Electronic Preset Meter RF3 (EPM RF3) is equipped with RF (radio frequency) communications to communicate with a 

fluid management system keypad to get authorization and dispense information. This is referred to in the manual as the  

RF Mode.
The meter can also be run as a standard EPM. This is referred to in the manual as the EPM Mode. This is intended for start-up 

purposes or when the fluid management system is not in use. 
Once a work order has been entered at the keypad, the operator simply pushes the 

RESET

 button on the meter to start 

communications between the meter and the keypad. The meter receives authorization from the keypad to unlock and the 

dispense batch quantity. When the trigger is pulled the preset dispense batch quantity dispenses. 
The meter automatically shuts off when the dispense batch quantity has been reached. 
A Topoff feature allows additional fluid to be dispensed and tracked after the batch quantity has been dispensed. 
Upon completion of the dispense, the operator presses the 

RESET 

button. The meter then locks, prohibiting any unauthorized 

dispense of fluid to occur, and the dispense quantity is sent to the keypad.

Meter Buttons

10, 1, 0.1

Used to enter the dispense Batch quantity when 

in the EPM Mode. These buttons are 

NOT

 used in 

RF Mode.

TOTAL

Used to display the accumulated total of fluid 

dispensed, as well as the re-settable total.

AUTO

Used to enter and exit the manual or batch mode 

when in EPM mode. This button is 

NOT

 used in 

RF mode.

RESET

• 

Used to initiate RF communications from the 

meter to the Keypad.

• 

Used in EPM mode to clear the previous 

batch.

• 

Used to reset the re-settable total dispensed 

while pressing the TOTAL button.

SHUTOFF 

or

 

STOP

Used to stop the flow through an Emergency 

Override.

LCD Display

1

2

3

4

5

6

7

1

Displays resettable total, accumulated total and scale 

factor 

2

Displays unit of measure 

3

Arrows flash when RF communication is in progress with 

the keypad 

4

Preset Batch quantity 

5

History Icon 

6

AUTO is an indicator of being in EPM mode 

7

Low Battery Icon

Page 7 

November 2012

Содержание epm-3

Страница 1: ...Electronic Preset Meter Model EPM 3 RF 2 4 GHz Installation Operation Manual IOM 197 02 EN November 2012 53400 197 Rev 2...

Страница 2: ...Electronic Preset Meter Model EPM 3 RF 2 4 GHz Page ii November 2012...

Страница 3: ...ng to an FMS Network 10 History Icon 11 Error Codes 11 METER OPERATION EPM MODE 12 EPM Manual Mode 12 EPM Batch Mode 12 Return to RF Mode 13 OPERATING MODE FUNCTIONS 14 Resettable Accumulated Totals 1...

Страница 4: ...Electronic Preset Meter Model EPM 3 RF 2 4 GHz DIMENSIONS 20 SPECIFICATIONS 20 PARTS LIST 21 TROUBLESHOOTING 24 MAINTENANCE 25 Low Battery Indicators 25 Changing the Batteries 25 Page iv November 2012...

Страница 5: ...y Read all instructions tags and labels before operating the equipment Use the equipment only for its intended purpose Do NOT modify or alter the equipment Do NOT leave equipment unattended while disp...

Страница 6: ...mation Record the product identification numbers from the nameplate here Model Number _______ Serial Number _______ Tag Number _______ if applicable Certification Contains FCC ID S4GEM35XB Contains IC...

Страница 7: ...cked after the batch quantity has been dispensed Upon completion of the dispense the operator presses the RESET button The meter then locks prohibiting any unauthorized dispense of fluid to occur and...

Страница 8: ...ations Air and Fluid Hoses use only grounded hoses Air Compressor follow manufacturers recommendations Fluid Supply Container follow the local code Possible Explosion and Fire Movement of fluids throu...

Страница 9: ...of the hose must have male threads Apply thread sealant Loctite 243 or equivalent to the male end The inlet and outlet swivel connections are either 1 2 NPT or 1 2 BSPP depending on meter model Apply...

Страница 10: ...noid valve automatically locks the dispensing valve in the full open position The trigger falls back to the closed position It is not necessary to continue to hold the trigger After the batch quantity...

Страница 11: ...not configured to a keypad To clear the error code press the RESET button on the meter Verify that the meter radio address is configured properly F03 System busy To clear the error press the RESET but...

Страница 12: ...right hand corner of the screen The meter is now in Batch Mode 1 Change the batch size by pressing the 10 1 and or 0 1 buttons a Press the 10 button to increase the batch amount in increments of 10 u...

Страница 13: ...zero batch quantity on the display You ll see the flashing arrows indicating the meter is communicating with the RF System 3 When communication is complete the meter returns to the RF Mode and the tri...

Страница 14: ...button while viewing RESETTOTAL to set it back to zero 4 Release the TOTAL button to return to the operating display NOTE N The Accumulated Total cannot be reset unless the you change the unit settin...

Страница 15: ...vised after field installation Use the Scale Factor showing on the display not the one written on the trigger IMPORTANT Changing the Scale Factor changes the accuracy of the meter potentially causing...

Страница 16: ...e Factors for Fluids of Different Viscosities Fluid Viscosity Scale Factor Water Anti Freeze 5 1 044 Anti Freeze 18 1 007 Brake Fluid 42 1 004 ATF 80 1 002 10W 140 1 000 80W 90 450 0 999 140W 1800 0 9...

Страница 17: ...10 1 or 0 1 to decrement a PIN digit 5 Press RESET to confirm PIN and enter the programming mode with Scale Factor and Unit of Measure screen displayed 6 Push and hold AUTO and TOTAL for 2 seconds to...

Страница 18: ...sary press and hold the TOTAL and AUTO buttons until the display flashes three times then goes blank OR Press the RESET button to advance to the EPM Manual Mode Enable screen Verifying Changes Press a...

Страница 19: ...e you can view the Radio Network by holding down the TOTAL button while pressing the 10 button Power Level Display 1 The radio power level is set at the factory The display is for validation purposes...

Страница 20: ...m 5 psi 0 35 bar Operating Temperature Maximum 120 F 50 C Operating Temperature Minimum 20 F 5 C Accuracy Oils 0 5 0 5 Accuracy Anti freeze 1 5 1 5 5 Digit LCD Display 10 mm high x 5 mm wide Quarts li...

Страница 21: ...Installation Operation Manual PARTS LIST Item Description Part Number 1 Battery holder assembly 64103 026 2 Bottom case with screws and radio 64103 029 3 Solenoid 64786 002 Page 21 November 2012...

Страница 22: ...eset Meter Model EPM 3 RF 2 4 GHz 1 2 3 Item Description Part Number 1 Rubber boot 65546 001 2 Display assembly 64103 023 3 RF register assembly 64103 030 Not Shown Swivel NPT AFLAS 64082 007 Page 22...

Страница 23: ...Installation Operation Manual 1 2 3 Item Description Part Number 1 Valve assembly AFLAS 64103 020 2 LCP gear set with AFLAS o ring 62896 003 3 Trigger assembly 64103 015 Page 23 November 2012...

Страница 24: ...ss RESET button Batteries dead Replace batteries Press RESET button Meter does not latch for batching Meter not in AUTO mode Press AUTO button and program batch size Meter not reset after prior batch...

Страница 25: ...s too low and meter functions are disabled Changing the Batteries The battery compartment is located in the lower case on the backside of the trigger guard 1 Position the unit face down 2 Unscrew the...

Страница 26: ...Electronic Preset Meter Model EPM 3 RF 2 4 GHz INTENTIONAL BLANK PAGE Page 26 November 2012...

Страница 27: ...Installation Operation Manual INTENTIONAL BLANK PAGE Page 27 November 2012...

Страница 28: ...Badger Meter de las Americas S A de C V Pedro Luis Ogaz n N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Middle East and Africa Badger Meter Europa GmbH...

Отзывы: