DESCOIPTION
Designed to meet the ever-changing requirements of flow metering, the Model 4050 flow computer can be tailored to
virtually any flow application It can accept up to three meters, correct for temperature changes and produce a usable output
in any flow unit The Model 4050 flow computer can work with manifold systems and switch relays with adjustable trigger
points This output can be used to change valve states and select active flow meters
Each Model 4050 flow computer is programmed to your individual requirements, and software is written for each unit when
required Each Model 4050 flow computer comes standard with a frequency input card, an analog input card, a relay card and
a communication card Other cards are optional as shown below Please contact your distributor for additional options
Optional Cards and Features
Frequency Input Card
3 frequency inputs
32-point linearization curve
Programmable factor for unit conversion
Programmable cutoff points down to 0 02 seconds
Analog Input Card
16-bit resolution
Six analog process
inputs
Used for temperature, flow, density, viscosity, and pressure (absolute, barometric,
gauge or differential) sensors
0…10V or 4…20 mA
5-point linearization curve
Programmable mass factor for unit conversion
Analog Output Card
16-bit resolution
Three analog outputs
Used for connection to remote facilities such as alarms, indicators, chart recorders,
Programmable Logic Controllers (PLCs) and more
0…10V or 4…20 mA
Configurable analog output reference parameter
Pulse Output Card
Three collector outputs
Transistor-transistor Logic (TTL) or Open
Used for retransmission of rate or output of pulses per unit volume of total
Can connect to remote indicators, totalizers or Programmable Logic Controllers(PLCs)
Oelay Card
Three volt-free relays
Deployable for alarm purposes
Can be used to control solenoid valves or pump starters with a batching unit
or controller
Communication Card
RS232 and RS485
interfaces
Monitor parameters or program calibration data
Serial or parallel port
Connection to panel or desk-mounted printers
Option of time and date indication
Main Display
Alphanumeric with red dot matrix characters
Exceptionally wide
viewing range
5 98 in (152 mm) × 0 71 in (18 mm)
Three display fields
Left: five characters for parameter identity or designation
Center: readout of quantity being measured
Right: units of measurement
Customization
Units
Test Routines
Buzzer
Data Entry
All calibration data is entered using the handheld infrared remote control after a successful passcode entry
To prevent incorrect data entry, when two Model 4050 flow computers are positioned in close proximity, the
reception of the computer that is not being addressed can be inhibited by a sequence of keystrokes on the
front panel of that computer (See
"Disabling and Enabling the Remote Control" on page 13
for
more information)
Description