Badger Meter Blancett B411-110 Скачать руководство пользователя страница 12

Turbine Flow Meter, Top Load 1 in. and 2 in. Meters

www.badgermeter.com

BLANCETT is a registered trademark of Badger Meter, Inc� Other trademarks appearing in this document are the property of their respective entities� Due to 

continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except 

to the extent an outstanding contractual obligation exists� © 2018 Badger Meter, Inc� All rights reserved� 

Control. Manage. Optimize.

The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq� Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Eastern Europe Branch Office (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul� Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0
Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836
Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11  

 

Содержание Blancett B411-110

Страница 1: ...Turbine Flow Meter Top Load 1 in and 2 in Meters TRB UM 02597 EN 01 September 2018 User Manual...

Страница 2: ...Pressure Drop Chart 7 Operational Startup 7 Turbine Assembly Replacement 8 Turbine Assembly Repair Kit Part Number 8 Turbine Assembly Replacement Procedure 8 Specifications 10 Part Number Information...

Страница 3: ...he oil field The meter features a rugged 316 stainless steel housing rotor shaft and rotor support assemblies a Buna N O ring C17 4PH stainless steel rotor and hybrid ceramic ball bearings with AMS 58...

Страница 4: ...ENT DE VITESSE LEV E Remove any restriction in the flow line that may cause the liquid to flash If necessary install air eliminators so the meter is not incorrectly measuring entrained air or gas Badg...

Страница 5: ...turbine rotor spins freely prior to installation Also check fluid lines and remove any debris found 2 Install the flow meter with the flow arrow etched onto the exterior of the meter body pointing in...

Страница 6: ...nd Flow Rate Control Valve 5 Pipe Diameters Turbine Flow Meter 10 Pipe Diameters Electronic Flow Monitor Figure 2 Meter installation with a bypass line Electronic Flow Monitor Control Valve 5 Pipe Dia...

Страница 7: ...IN AN EXISTING SYSTEM AVERTISSEMENT ASSUREZ VOUS QUE LE FLUX DE FLUIDE A T COUP ET DE LA PRESSION DANS LA LIGNE A T LIB R E AVANT D ESSAYER D INSTALLER LE M TRE DANS UN SYST ME ACTUEL HIGH VELOCITY A...

Страница 8: ...art Number Repair Kit Part Number 1 in B411 110 B411005 2 in B411 120 B411006 Table 2 Repair kits For 1 in Meter B411 110 For 2 in Meter B411 120 Description Repair Part Number B251 610 B251 620 Compl...

Страница 9: ...ccurate measurements 1 Shut off the fluid flow and release any residual pressure in the line 2 Remove the wiring from the magnetic pickup 3 Remove the external retainer ring from the meter Set it asid...

Страница 10: ...of reading Repeatability 0 1 Calibration Water NIST traceable calibration Pickup B111129 Certifications PART NUMBER INFORMATION 1 Part Number Bore Size End Connections Max PSI Flow Ranges Strainer Mes...

Страница 11: ...t off Mechanical vibration causes rotor to oscillate without turning Isolate meter No flow indication Full or partial open position Fluid shock full flow into dry meter or impact caused bearing separa...