Trouble

Possible Cause

Remedy

Meter indicates higher than 

actual flow rate

• 

Cavitation

• 

Debris on rotor support

• 

Build up of foreign material 

on meter bore

• 

Gas in liquid

• 

Increase back pressure

• 

Clean meter

• 

Clean meter

• 

Install gas eliminator ahead 

of meter

Meter indicates lower than 

actual flow rate

• 

Debris on rotor

• 

Worn bearing

• 

Viscosity higher than 

calibrated

• 

Clean meter and add filter

• 

Clean meter and add filter

• 

Recalibrate monitor

Erratic system indication, 

meter alone works well 

(remote monitor application 

only)

Ground loop in shielding

Ground shield one place only� 

Look for internal electronic 

instrument ground� Reroute 

cables away from electrical 

noise

Indicator shows flow when 

shut off

Mechanical vibration causes rotor 

to oscillate without turning

Isolate meter

No flow indication

Full or partial open position

Fluid shock, full flow into dry 

meter or impact caused bearing 

separation or broken rotor shaft

Rebuild meter with repair kit 

and recalibrate monitor� Move 

to location where meter is full 

on startup or add downstream 

flow control valve

Erratic indication at low flow, 

good indication at high flow

Rotor has foreign material 

wrapped 

around it

Clean meter and add filter

No flow indication

Faulty pickup

Replace pickup

System works perfect, except 

indicates lower flow over 

entire range

Bypass flow, leak

Repair or replace bypass valves, 

or faulty solenoid valves

Meter indicating high flow, 

upstream piping at meter 

smaller than meter bore

Fluid jet impingement on rotor

Change piping

Opposite effects of above

Viscosity lower than calibrated

Change temperature, change 

fluid or recalibrate meter

Содержание Blancett B133C-380

Страница 1: ...Turbine Flow Meter QuikSert Explosion Proof TRB UM 00287 EN 07 June 2020 User Manual...

Страница 2: ...Turbine Flow Meter QuikSert Explosion Proof Page ii June 2020 TRB UM 00287 EN 07...

Страница 3: ...ction 5 Operating Principle 5 Installation 7 Operational Startup 9 Troubleshooting Guide 10 Specifications 11 Pressure Rating 11 Meter Parts 12 Part Number Information Pickup Not Included 13 Flow Rang...

Страница 4: ...age that may have occurred during shipment OTE N If damage is found request an inspection by the carrier s agent within 48 hours of delivery and file a claim with the carrier A claim for equipment dam...

Страница 5: ...ts volumetric flow rate With optional Blancett electronics QuikSert provides local flow rate and volume totalization and will interface with most instruments PLCs and computers OPERATING PRINCIPLE Flu...

Страница 6: ...TRB UM 00287 EN 07 Figure 2 Etching OTE N For easy reference the meter specifications that include part number serial number maximum working pressure and minimum and maximum operating temperature are...

Страница 7: ...fittings suitable for the installation area onto the conduit adapter hub on the flow meter The liquid being measured should be free of any large particles that may obstruct rotation of the rotor If pa...

Страница 8: ...meter accuracy may be affected Piping should be the same size as the meter bore or threaded port size Do not locate the flow meter or connection cable close to electric motors transformers sparking d...

Страница 9: ...alve Flow liquid through the bypass valve for sufficient time to eliminate any air or gas in the flow line HIGH VELOCITY AIR OR GAS MAY DAMAGE THE INTERNAL COMPONENTS OF THE METER 2 Open upstream isol...

Страница 10: ...tor shows flow when shut off Mechanical vibration causes rotor to oscillate without turning Isolate meter No flow indication Full or partial open position Fluid shock full flow into dry meter or impac...

Страница 11: ...p B111109 B220111 B220210 B220243 B111126 Conformance NACE MR0175 ISO 15156 Pressure Standards Approvals Canadian Registration Number CRN PED 2014 68 EU Group 1 Category II Pulsation and Vibration Sev...

Страница 12: ...Pickup Not Included Rotor Support Meter Body Conduit Adapter Retaining Ring Figure 5 Typical cross section of models B131C 038 B131C 100 Rotor Assembly Thrust Ball Bushing Magnetic Pickup Not Include...

Страница 13: ...139C 900 10 10 Coming soon 4 1 6 10 Flow Range Chart Part Number Flow Ranges gpm lpm bpd m3 d B131C 038 0 60 3 00 2 27 11 36 20 100 3 3 16 B131C 050 0 75 7 50 2 84 28 39 25 250 4 1 41 B131C 075 2 00 1...

Страница 14: ...Repair Kit Part Number Max Pressure Drop Dimensions Diameter Length in mm B131C 038 B253 102 3 75 psi 2 4 50 4 101 6 B131C 050 B253 105 6 5 psi 2 4 50 4 101 6 B131C 075 B253 108 18 psi 2 4 50 4 101 6...

Страница 15: ...INTENTIONAL BLANK PAGE User Manual June 2020 TRB UM 00287 EN 07 Page 15...

Страница 16: ...t are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product or system specifications without noti...

Отзывы: